Tags: 3D Flux Gate Sensor Flux Gate Array Flux Gate Multi point Measurement GFP803 Data Processing Unit Weak Magnetic Measurement Geomagnetic Measurement
Provide professional magnetic field measurement solutions | ||||||
Strong magnetic field measuring instrument(0 - 20T) | ||||||
model |
principle |
type |
number of axles |
DCaccuracy |
maximum range |
Highest resolution |
X113 |
hall |
hall sensor |
1 |
<> |
15T |
TC: 30ppm/K |
G80 |
hall |
handheld |
1 |
2% |
2T |
10μT |
G81 |
hall |
handheld |
1 |
0.8% |
10T |
1μT |
G82 |
hall |
handheld-high frequency |
1 |
0.8% |
10T |
1μT |
G83 |
hall |
handheld |
3 |
0.8% |
10T |
1μT |
G92 |
hall |
handheld |
1 |
1% |
10T |
10μT |
G93 |
hall |
handheld |
3 |
1%, 0.5% |
20T |
1μT |
G201 |
hall |
Desktop computer |
1 |
0.2% |
10T |
1μT |
G203 |
hall/reluctance |
Desktop computer |
3 |
0.2% |
10T |
10nT |
G401 |
hall |
Desktop computer |
1 |
0.04% |
10T |
1μT |
G403 |
hall |
Desktop computer |
3 |
0.04% |
10T |
1μT |
GSP301A |
hall |
Analog transmitter |
1 |
1%, 0.2% |
10T |
Output: ±3V |
GSP301D |
hall |
Digital transmitter |
1 |
1%, 0.2% |
10T |
1μT |
GSP303D |
hall |
Digital transmitter |
3 |
1%, 0.2% |
20T |
1μT |
GSP303D-S |
hall |
Digital transmitter |
3 |
0.5%, 0.1% |
3T |
1μT |
Magnetic field testing system | ||||||
GAS3000 |
Array magnetic field detection system, synchronous detection up to128The magnetic field at a certain location |
|||||
GMS980 |
High precision Gaussian meter calibration system (High precision Tesla meter calibration device) |
|||||
Weak magnetic field measuring instrument(0- 2mT) | ||||||
Weak magnetic field Gaussian meter | ||||||
model |
principle |
type |
number of axles |
DCaccuracy |
maximum range |
Highest resolution |
GMR61 |
reluctance |
handheld |
1 |
0.8% |
600μT |
10nT |
GMR63 |
reluctance |
handheld |
3 |
0.8% |
600μT |
10nT |
GF601 |
fluxgate |
handheld |
1 |
0.5% |
1mT |
0.1nT |
GF603 |
fluxgate |
handheld |
3 |
0.25% |
1mT |
0.1nT |
GF633 |
fluxgate |
Desktop computer |
3 |
0.1% |
100μT |
0.01nT |
GFP703 |
fluxgate |
Smart Transmitters |
3 |
0.5% |
1mT |
0.1nT |
GFP703S |
fluxgate |
Spectrum analyzer |
3 |
0.5% |
1mT |
0.01nT |
GFP803 |
fluxgate |
Smart Transmitters |
3 |
0.2% |
1mT |
0.1nT |
Communication magnetic field measurement(DC- 1MHz) | ||||||
model |
principle |
type |
number of axles |
ACaccuracy |
maximum range |
frequency response |
AMS-2K |
alternating current coil |
Analog sensor |
1 |
1% |
3mT |
30Hz- 2kHz |
AMS-1M |
alternating current coil |
Analog sensor |
1 |
1% |
3mT |
2kHz- 1MHz |
G1000 |
reluctance |
Smart Transmitters |
3 |
DC- 1% AC- 2% |
400μT/ Axis |
DC- 1MHz |
GA1000 |
reluctance |
handheld |
3 |
2% |
400μT/ Axis |
30Hz- 1MHz |
GSP301HFA |
reluctance |
Analog transmitter |
1 |
1% |
150μT |
20Hz-1.2MHz |
GSP303HFA |
reluctance |
Analog transmitter |
1 |
1% |
150μT |
20Hz-1.2MHz |
fluxgate sensor | ||||||
model |
principle |
type |
number of axles |
noise level |
maximum range |
output |
F901 |
fluxgate |
Economic type |
3 |
10 to 20pT |
1000μT |
±10V,single-ended |
F902 |
fluxgate |
low noise |
3 |
<> |
100μT |
±10V,single-ended |
F903 |
fluxgate |
low-power consumption |
3 |
10 to 20pT |
200μT |
±3V,finite difference |
F904 |
fluxgate |
low-power consumption|low noise |
3 |
<> |
100μT |
±3V,finite difference |
F905 |
fluxgate |
high-performance|low noise |
3 |
<> |
100μT |
±10V,single-ended |
F906 |
fluxgate |
low-power consumption |
3 |
10 to 20pT |
100μT |
±3V,finite difference |
F23 |
fluxgate |
split type|large range |
3 |
<> |
1500μT |
±10V,single-ended |
F53 |
fluxgate |
High temperature type |
3 |
≤ 300pT@175℃ |
100μT |
±5V,finite difference |
Magnetic flux gate sensor data acquisition unit | ||||||
FDU301 |
Connectable1A three-axis flux gate sensor |
|||||
ASA1000 |
Connectable2-126A single axis flux gate sensor or2-42A three-axis flux gate sensor |
|||||
AFS |
Array flux gate sensor detection system, capable of connecting multiple flux gate magnetic field transmitters |
|||||
GMR-16 |
Micro weak magnetic field sensor array, capable of synchronous acquisition2-16Data from a miniature weak magnetic field sensor |
|||||
GR100 |
Digital three-axis flux gate gradiometer |
|||||
remarks: 1Magnetic field unit conversion:1T= 10kG; 1mT= 10G; 1μT= 10mG; 1nT= 10μG 2Click on the left side of the table abovemodelYou can refer to the product information of the corresponding model |
AFS array flux gate sensor detection system
sketch:
The array flux gate sensor detection system AFS consists of multiple three-dimensional flux gate sensors (up to 128), high-speed RS485 communicator, USB converter, upper computer software, and computer. The array flux gate sensor detection system AFS can meet the needs of weak magnetic field multi-point testing in scientific research units. It has the advantages of fully automatic bus based digital signal transmission, computer-controlled acquisition speed, data storage and processing, drawing various curve charts, spectrum and RMS analysis (options).
The array flux gate sensor detection system AFS can simultaneously connect 1-128 three-dimensional flux gate sensors, with each sensor having an accuracy of<><>
Option: Each flux gate sensor can not only output three-dimensional magnetic field data at high speed, but also perform frequency spectrum analysis of AC magnetic fields and calculate the total RMS data. Spectrum analysis range 2Hz-500Hz, frequency accuracy 1Hz, RMS magnetic field accuracy<>
The array flux gate sensor detection system AFS is suitable for multi-point testing of various weak magnetic fields in space, multi-point online monitoring of environmental magnetic fields, magnetic ship model magnetic field measurement experiments, on-site testing of electron microscopy and magnetic resonance equipment pre installation, and judgment of magnetic shielding effect. The array flux gate sensor detection system AFS can be customized according to user needs to meet their special requirements.
Performance advantages:
●The system can connect up to 128 3D flux gate sensors;
●The range of the 3D flux gate sensor is optional, with a measurement resolution of up to 0.1nT;
●Simultaneous acquisition by multiple probes and synchronous display by computer software;
●Adopting industrial grade RS485 high-speed communicator, fast speed and high stability;
●Computer controlled acquisition speed and data processing, fully automated bus based digital signal transmission;
●The communication cable can reach a maximum length of 500 meters.
Upper computer software
AFS array flux gate sensor detection system
Array Flux Gate Sensor Detection System |
describe |
computer | |
operating system |
Win8, Win10 |
Configuration Requirements |
Conventional mainstream configuration |
systems software | |
function |
1Real time display of magnetic field strengthXYZComponent value and vector value 2Real time saving of magnetic field strength data to computer 3Spectrum andRMSMeasurement mode (option) 4Multi probe connection and display mode(128Within one probe |
MSCSynchronous collector | |
Number of channels |
8, 16, 32, 64, one hundred and twenty-eightoptional |
Working power supply |
DC 9-40V 500mA |
Communication Distance |
500rice |
Transmission medium |
Twisted pair or shielded wire |
Usage environment |
-20℃~ +85℃Relative humidity>95%RH |
Three dimensional flux gate sensor | |
power supply |
±15V DC |
range |
±100μTor±1000μT[optional] |
typicalDCaccuracy |
±0.2% Reading ± 0.1% FS |
Highest measurement resolution |
full scale0.1nT(Sensor range)100uTData output rate<>) full scale0.1nT (Sensor range1000uTData output rate<> |
frequency response(-3dB) |
DC- 1.5kHz |
Typical temperature coefficient |
±200ppm/℃[Without temperature compensation] ±30ppm/℃[After temperature compensation] |
Spectrum analysis andRMSMeasurement function |
2Hz-500HzFrequency accuracy1Hz,RMSaccuracy<1% >1% >[optional] |
Sensor orthogonality error |
<1°>1°>or<>[optional] |
Data output interface |
RS485 |
3Output rate of magnetic field data |
1, 5, 10, 50, 100, 500, 1000spsoptional |
operation temperature |
-30℃~ +60℃ |
size(L x W x H) |
151 x 32 x 32mm |
protection grade |
IP68 |
Product Selection
1. Selection of RS485 high-speed communicator
MSC |
-8 |
MSCSynchronous collector |
Number of connection channels (Number of 3D flux gate sensors that can be connected)
-8:8individual -16:16individual -32:32individual -64:64individual -128:128individual |
2. Selection of Three Dimensional Flux Gate Sensors
GFP803 |
-01 |
-2m |
-E |
-T |
-DS |
Three dimensional flux gate sensor
|
range
-01:100μT -10:1000μT |
Cable Length
-2m:2m -5m:5m -10m:10m -20m:20m …… |
Orthogonality error
Default:<>
-E:<> |
temperature compensation
Default: None
-Thave |
Package Specifications
Default: Normal encapsulation
-DS: Deep diving(underwater50rice) |
※※※Click to view other magnetic measurement devices ※※※ |