Suzhou Oulunde Machinery Co., Ltd
Home>Products>15 horsepower air-cooled chiller, Suzhou chiller manufacturer, AC-15AT chiller
15 horsepower air-cooled chiller, Suzhou chiller manufacturer, AC-15AT chiller
15 horsepower air-cooled chiller, Suzhou chiller manufacturer, AC-15AT chiller
Product details

15 horsepower air-cooled chiller, Suzhou chiller manufacturer, AC-15AT chiller

contactsYang: 158-5038-4926

Suzhou chiller, Changshu chiller, Zhangjiagang chiller, Wuxi chiller, Taicang chiller, choose Suzhou Alunde chiller manufacturer, welcome to consult Suzhou Alunde Machinery Co., Ltd!

AC-15AD chiller, 15 horsepower chiller, dual head chiller, vortex chiller, Suzhou chiller manufacturer, Kunshan chiller manufacturer, Dalian chiller manufacturer, branded compressor, export chiller

15 horsepower air-cooled chillerThe parameters are as follows:

1、 Chiller parameter table:

AC-15AD air-cooled chiller specifications and technical parameters table

Serial Number name Specification type performance parameter

1 model AC-15AD

2 Refrigeration capacity kW 44.15 (outlet temperature 10 ℃, condensing temperature 50 ℃)

kcal/h 37965 (outlet temperature 10 ℃, condensing temperature 50 ℃)

3 power supply V 3PH-380V-50HZ

4 Whole machine power kW 17.0

5 Whole machine current A 41.3

6

compressor type Fully enclosed vortex type

Cooling input power(kW) 3.75+7.5

Cooling operation current(A) 41.3

7 fan type YWF

Air volume(m3/h) 15000

8 water pump type Centrifugal pipeline pump

lift(mH2O) 18

internet traffic(m3/h) 12

9 condenser type Aluminum finned copper tube type

heat exchange(kW) 55.15

10 evaporator type Shell and tube type

heat exchange(kW) 45.0

internet traffic(m3/h) 7.6

11 water tank material SUS304

volume(L) 285

12 Piping Frozen water media outlet DN50 (according to customer requirements)

Frozen water media inlet DN50 (according to customer requirements)

13 Temperature digital microcomputer controller Display status Touch sensitive digital tube display

output Gw532A

Generator selection Relay

Temperature range(℃) +5~+35

Temp Accuracy(℃) ±1.0

14

alarm device Abnormal temperature Alarm for low circulating water temperature and cut-off of compressor

Reverse phase of power supply Power phase detection to prevent pump and compressor reversal

High and low voltage faults Pressure switch detects the pressure status of the refrigerant system

Compressor overload Thermal relay protects compressor

Compressor overheating Internal protector protects the compressor

Pump overload Thermal relay protection pump

Low water level alarm The water level switch

short circuit Air Switch

15 External dimensions long*Width * Height (mm) 1680*890*1600

16 Whole machine weight kg 520