1、 Overview
This equipment is mainly used to detect discontinuities such as pores or other defects in metals and their alloys, metal coatings, organic coatings, anodic oxidation films, and conversion films. This salt spray machine laboratory uses thermal radiation heating to maintain the required temperature of the testing space, thereby ensuring the accuracy of the test.
2、 Meet the standards for testing methods and equipment execution
GB/T2423.17-2008/IEC 60068-2-11-1981 Salt spray test method
ASTM.B117-2011 Salt Spray Test
ASTM-B368-09 Standard Test Method for Copper Acetate Salt Spray Test (CASS Test)
JIS H8502 Salt water spray test method
GB/T10125-2012/ISO 9227-2006 Salt water spray test method
GB-T5170.8-2008 Inspection methods for environmental testing equipment for electrical and electronic products - Salt spray testing equipment
GB-T5170.11-2008 Inspection methods for corrosive gas testing equipment
GB-T10587-2006 Technical Conditions for Salt Spray Test Chamber
GBT 20121-2006/ISO11474-1998 Corrosion of metals and alloys - Corrosion tests in artificial atmospheres - Outdoor accelerated tests under intermittent salt spray
PRODUCT MODEL | CZ-TB-500CY | CZ-TB-1600CY | CZ-TB-2000CY |
---|---|---|---|
Inner box ruler (mm) W × H × D | 1000×650×720 | 1600×800×1000 | 2000×800×1000 |
Outer box ruler (mm) W × H × D | 1700×1400×1000 | 2300×1600×1250 | 2700×1600×1250 |
Temperature range of laboratory | RT+5℃~60℃ | ||
Saturation bucket temperature range | RT~ 70℃ | ||
Humidity range | ≥90RH | ||
Salt water spray volume | 1 ~ 2ml/80cm2/h (average value for at least 16 hours of spray) | ||
Spray Pressure | 70~170KPa | ||
PH value of the medicine | 6.5~7.2 / 3.0~3.2 | ||
Collect the pH value of the liquid | 6.5~7.2 / 3.1~3.3 | ||
Sample placement angle | 20 ± 5 ° (tilted from the vertical plane) | ||
Internal/External Box Material | Inner titanium plate, outer stainless steel plate baked with paint | ||
Spray mode | Continuous spray, periodic spray, self selection | ||
Control accuracy | Temperature deviation: ± 2.0 ℃ | ||
control system | Color LCD touch screen controller | ||
Power supply conditions | AC220V 50/60HZ single-phase two-wire+protective grounding |