ZYC type self operated differential pressure control valve
purpose
ZYC type self operated differential pressure control valve is an energy-saving product that uses the pressure changes of the medium itself for self-control to maintain the constant pressure difference of the medium flowing through the controlled system. Suitable for pressure difference control in heating systems using dual pipe systems, ensuring that the pressure difference of the system remains basically unchanged, reducing noise, balancing resistance, and eliminating hydraulic imbalance in the heating network.
|
|
Working principle
Taking the ZYC type self operated differential pressure control valve installed on the return water pipeline as an example to illustrate its working principle. When the water supply pressure p1 increases or decreases, the signal is transmitted through the connecting pipe to the upper chamber of the diaphragm, which drives the valve core to move downwards, reducing or increasing the flow area of the valve seat. P2-P3 also increases or decreases until P1-P2 maintains its original value constant. At the moment when the return water pressure P3 increases or decreases, the flow velocity towards the outlet of the valve seat decreases or increases, and the pressure P2 under the diaphragm also increases or decreases at this moment, driving the valve core to move up or down. Knowing that the force on the diaphragm is re balanced, P2 returns to its original value, and P1-P2 protects the original value constant, thus ensuring that the pressure difference between the supply and return water of the controlled system is basically inconvenient.
Dimensions of ZYC Type Self operated Differential Pressure Control Valve
DN(mm) |
Connection method |
L(mm) |
H |
H1 |
Flow rate m3/h |
Applicable Medium |
medium temperature |
15 |
thread |
110 |
72 |
98 |
0.2-1 |
water |
0~80℃s |
20 |
110 |
72 |
98 |
0.3-1.5 |
|||
25 |
115 |
82 |
102 |
0.5-2 |
|||
32 |
flange |
160 |
91 |
94 |
1-4 |
||
40 |
200 |
147 |
112 |
1.5-6 |
|||
50 |
215 |
120 |
112 |
2-8 |
|||
65 |
220 |
125 |
120 |
3-12 |
|||
80 |
275 |
188 |
133 |
5-20 |
|||
100 |
290 |
208 |
160 |
10-52 |
|||
125 |
310 |
226 |
175 |
15-45 |
|||
150 |
350 |
258 |
195 |
30-80 |
|||
200 |
430 |
301 |
230 |
40-180 |
|||
250 |
520 |
367 |
265 |
100-300 |
|||
300 |
635 |
430 |
300 |
150-500 |
|||
350 |
670 |
504 |
340 |
200-700 |
Installation diagram | |
|
Water supply installation, the control pressure difference of the self operated differential pressure control valve is P2-P3, and the working pressure difference on the valve is P1-P2 Backwater installation, the control pressure difference of the self operated differential pressure control valve is P1-P2, and the working pressure difference on the valve is P2-P3 |