Jiangsu Zhongneng Instrument Technology Co., Ltd
Home>Products>ZNBMA high static pressure differential pressure transmitter
ZNBMA high static pressure differential pressure transmitter
1、 Product Introduction of ZN130A High Static Pressure Differential Pressure Transmitter:
Product details

1 ZN130AHigh static pressure differential pressure transmitterProduct Introduction:

High static pressure differential pressure transmitter ZN130AHigh static pressure differential pressure transmitter
M membrane box H membrane box
measuring range -100~100kPa
(-400~400inH2O)
-500~500kPa
(-2000~2000inH2O)
Measurement range 1~100kPa
(4~400inH2O)
5~500kPa
(20~2000inH2O)
accuracy ±0.0653332% ±0.065232%
protection grade IP67,NEMA 4X, And JIS C0920 immersion proof type
Explosion proof specifications FM,CENELEC ATEX,CSA,IECEx
output signal 4~20mA DC or FOUNDATION? Fieldbus or PROFIBUS PA two-wire digital communication
power supply BRAN and HART: 10.5~42V DC (intrinsic safety type: 10.5~30V DC)
Fieldbus: 9~32V DC (Intrinsic Safety Entity Mode 9~24V DC, Intrinsic Safety FISCO Mode 9~17.5V DC)
ambient temperature -40-85 ℃ (-40~185 ℉) (ordinary type)
-30~80 ℃ (-22~176 ℉) (with built-in indicator)
process temperature -40-120 ℃ (-40~248 ℉) (ordinary type)
Maximum working pressure 32MPa (4500psi)
install 2-inch pipe installation
Material of liquid receiving components Capsule SUS316L (diaphragm: Hastelloy C-276)
Container flange SUS316
casing Aluminum alloy or SUS316 stainless steel (optional)

IIZN130AProduct Selection Table for High Static Pressure Differential Pressure Transmitters

Item 1: Output signal
-D 4-20mA DC/BRAN protocol digital communication
-E 4-20mA DC/HART protocol digital communication
-F FF fieldbus communication
Item 2: Measurement range (membrane box)
M 1-100KPa
H 5-500KPa
Item 3: Material of the liquid receiving part

S

SUS316 SUS316L SUS316
Item 4: Process Interface
0 No process joint (Rc1/4 internal thread on chamber flange)
1 Rc1/4 internal thread process joint
2 Rc1/2 internal thread process joint
3 1/4NPT internal thread process joint
4 1/2NPT internal thread process joint
5 No process joint (1/4NPT internal thread on chamber flange)
Item 5: Material of bolts and nuts
A JIS SCM435 32MPa
B JIS SUS630 32MPa
C JIS SUH660 32MPa
Item 6: Installation Method
-2 Vertical piping connection, high pressure on the right, upper installation process joint
-3 Vertical piping connection, high pressure on the right, lower installation process joint
-6 Vertical piping connection, left high pressure, upper installation process joint
-7 Vertical piping connection, left high pressure, lower installation process joint
-8 Horizontal piping connection, high pressure on the right side
-9 Horizontal piping connection, high pressure on the left side
Item 7: Electrical Interface
0 G1/2 internal thread, one electrical interface
2 1/2NPT internal thread, two electrical interfaces, no blind plugs
3 Pg13.5 internal thread, two electrical interfaces, no blind plugs
4 M20 internal thread, two electrical interfaces, no blind plugs
5 G1/2 internal thread, two electrical interfaces, one blind plug
7 1/2NPT internal thread, two electrical interfaces, one blind plug
8 Pg13.5 internal thread, two electrical interfaces, one blind plug
9 M20 internal thread, two electrical interfaces, one blind plug
Item 8: Hidden Display Table
D Digital display table
E Digital display table with measurement range setting button
N not have
Item 9: Installing the bracket

 

A JIS SECC flat bracket
B JIS SUS304 flat bracket
C JIS SECC L-shaped bracket
D JIS SUS304 L-shaped bracket
N not have

 

III ZN130AHigh static pressure differential pressure transmitteradditional function

Item 1: Explosion proof/Intrinsic Safety Type
Not specified
NF1 NEPSI Explosion proof Permit: d Ⅱ CT6 Environmental Temperature: -40-60 ℃ Electrical Interface: 1/2NPT
FF1 FM Explosion proof Permit C1: I-II&III Div 1&2, Gps. B, C, D, E, F&G NEMA 4X Temperature: C1: T6
FF15 FM Explosion proof Permit C1: I-II&III Div 1&2, Gps. B, C, D, E, F&G NEMA 4X Temperature: C1: T6
KF1 CENELEC (KEMA) Explosion proof License: EExd Ⅱ CT4, T5, T6
KF5 CENELEC (KEMA) Explosion proof License: EExd Ⅱ CT4, T5, T6
CF1 CSA Explosion proof License C1: I-II&III Div, 1&2, GPS, B, C, D, E, F,&G ENCL: Type4X Temperature: CI: T4, T5, T6
CF15 CSA Explosion proof License C1: I-II&III Div, 1&2, GPS, B, C, D, E, F,&G ENCL: Type4X Temperature: CI: T4, T5, T6
NS1 NEPSI intrinsic safety license: ia Ⅱ CT4 environmental temperature: -40-60 ℃ electrical interface: 1/2NPT
FS1 FM intrinsic safety license intrinsic safety C1: I-II&III Div, 1&2, Gps, B, C, D, E, F,&G non combustible C1: I-II&III Div, 1&2, Gps, B, C, D, E, F&G
KS1 CENELEC (KEMA) intrinsic safety license: EEx ia Ⅱ CT4
CS1 CSA intrinsic safety license: C1: I-II&III Div, 1&2, GPS, A, B, C, D, E, F&G ENCL: Type4X Temperature C1: T4
FU1 Including FF1 and FS1
KU1 Including KF1.KS1 and N-type KEMA, N-type EX nAII CT4
CU1 Including CF1 and CS1
SU1 SAA explosion-proof and intrinsic safety and spark free Ex d Ⅱ CT6/T5/T4 IP67, Ex ia Ⅱ CT4 IP67, Ex n Ⅱ CT4 IP67
KS5 CENELEC (KEMA) intrinsic safety explosion-proof: [Entity mode]: EEx ia Ⅱ CT4; [Fisco mode]: EEx ia Ⅱ CT4/EEx ia Ⅱ BT4
Item 2: Explosion proof sealing joint
Not specified
G71 Connection port: 1/2NPT Applicable cable outer diameter: Φ 8.5 ± 0.5 (1 piece)
G72 Connection port: 1/2NPT Applicable cable outer diameter: Φ 8.5 ± 0.5 (1 piece)
G81 Connection port: 1/2NPT Applicable cable outer diameter: Φ 8.5 ± 0.5 (2 pieces)
G82 Connection port: 1/2NPT Applicable cable outer diameter: Φ 8.5 ± 0.5 (2 pieces)
Item 3: Painting: Color change or painting change
Not specified
P1 The color change only applies to the transmitter housing Munsell logo code: N1.5, black
P2 The color change only applies to the transmitter housing Munsell logo code: 7.5BG4/1.5 green
P7 The color change is only applicable to the silver metal of the transmitter housing
X1 Paint changes, epoxy resin baking
Item 4: Lightning Protection Device
Not specified
A Transmitter power supply voltage: 10.5-32V DC (intrinsic safety type: 10.5-30V DC) Maximum allowable current: 6000A (1X4 μ S), repeated 1000A (1X40 μ S) 100 times
Item 5: Prohibition of oil treatment or prohibition of water and oil treatment
Not specified
K1 Degreasing and cleaning treatment
K2 Defatting and cleaning treatment, and filling the membrane box with fluorine oil at a temperature of -20-80 ℃
K5 Defatting, washing and drying treatment
K6 Defatting, washing, and drying the membrane box, filling it with fluorine oil, and using it at a temperature of -20-80 ℃
Item 6: Calibration Unit
Not specified
D1 P correction (Psi unit)
D3 Bar calibration (bar unit)
D4 M correction (kgf/cm2)
Item 7: Sealing treatment of SUS630 nut
Not specified
Y Surface coating of SUS630 bolts and nuts for fastening chamber flange (liquid silicone rubber)
Item 8: Long exhaust plug
Not specified
U Total length: 112mm (standard type: 32mm)
Item 9: Quick Response
Not specified
F1 Refresh time: ≤ 0.125 seconds Response time (including minimum damping time constant): Maximum 0.3-0.5 seconds (L capsule 0.6 seconds)
Item 10: PID/LM Function
Not specified
LC1 PID control function, Link Master function
Item 11: Set the output to low when the CPU is abnormal
Not specified
C1 Low side: ≤ -5% (3.2mA DC)
Item 12: NAMUK NE43
Not specified
C2 [Output signal 3.8-20.5mA] Fault alarm output -5%, below 3.2mA
C3 [Output signal 3.8-20.5mA] Fault alarm output 110%, above 21.6mA
Item 13: Stainless steel amplifier housing
Not specified
E1 Amplifier casing material: SCS14A stainless steel (equivalent to SUS316L cast stainless steel or ASTM CF-8M)
Item 14: Gold plated film
Not specified
A1 Gold plating on sealing membrane
Item 15: Configuration
Not specified
R1 User Configuration Software
Item 16: Container flange options
Not specified
N1 Without exhaust and drain plugs
N2 N1 and without process joints, both sides of the chamber flange are machined with DIN 19213 7/16 inch × 20 internal threads (installation threads), and the rear side is equipped with a blind plug
N3 Manufacturing of accessories for N1 and N2 chamber flanges, diaphragms, bodies, and blind plugs
Item 17: Stainless Steel Tag Plate
Not specified
N4 JIS SUS304 stainless steel tag plate fixed on the transmitter
Item 18: Accessory Manufacturing Certificate
Not specified
M01 Container flange
M11 Container flange, process joint
Item 19: Proof of stress test leakage test
Not specified
T09 M. H membrane box test pressure: 32MPa test fluid: nitrogen retention time of 10 minutes

ZN130AHigh static pressure differential pressure transmitter

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!