XSK single channel thermal instrument
XSK single channel thermal instrument
Overview of XSK Instrument:
■ 0.2Grade accuracy, measurement and control speed per second10Secondly or40Secondary measurement and control speed can be set, display range-1999~9999.
■ Dual four digit digital display (main display)+The second display can be used to display information such as units of engineering quantity and alarm values.
■ Universal input, selected through settings.
■ Optional1~4Point alarm output. Including upper limit of measurement value, lower limit of measurement value, upper limit of deviation, lower limit of deviation, upper limit of absolute deviation value, lower limit of absolute deviation value, and fault alarm7Basic alarm methods and standby upper limit, standby lower limit, standby deviation upper limit, standby deviation lower limit4Standby alarm mode. (Standby alarm mode: refers to the situation where the instrument does not alarm when the measured value is in the output range when powered on, and establishes a standby condition when the measured value enters the non output range, and then alarms normally thereafter.).
■ 10Segment line correction function.
■ 1Click on the external switch input to reset.
■ Peak and valley value acquisition function.
XSK selection specifications:
content |
Code Description |
|||||||||||
XSK- |
Analog universal input, 0.2 level display accuracy; The measurement and control speed can be set to 10 or 40 times per second |
|||||||||||
External dimensions |
AH |
160×80×125horizontal typeHole size: 152 × 76(Note ①) |
||||||||||
AS |
80×160×125VerticalHole size: 152 × 76(Note ①) |
|||||||||||
B |
96×96×76Hole size: 92 × 92(Note 2) |
|||||||||||
CH |
96×48×82horizontal typeHole size: 92 × 45(Note ③) |
|||||||||||
CS |
48×96×82VerticalHole size: 92 × 45(Note ③) |
|||||||||||
D |
72×72×75Hole size: 68 × 68(Note ④) |
|||||||||||
E |
48×48×88Tray PackHole size: 45.5 × 45.5(Note ⑤) |
|||||||||||
Panel specifications |
Dual 4-digit LED display |
|||||||||||
Alarm (optional) (250V AC/3A, resistive load) |
A |
T1~T4 |
1The 4-point alarm relay outputs are both normally open and normally closed dual contacts |
|||||||||
O1~O4 |
1Around 4 o'clockOCGate output (voltage should be less than 40V DC, current should be less than 40mA) |
|||||||||||
B |
T1~T2 |
1~2-point alarm relay output, both with normally open and normally closed dual contacts |
||||||||||
T3~T4 |
3The 4-point alarm relay outputs are all single normally open contacts |
|||||||||||
O1~O4 |
1Around 4 o'clockOCGate output (voltage should be less than 40V DC, current should be less than 40mA) |
|||||||||||
C |
T1~T2 |
1~2-point alarm relay output, both with normally open and normally closed dual contacts |
||||||||||
T3 |
3Point alarm relay output, all with single normally open contacts |
|||||||||||
T3R |
3The output of the alarm relay is both normally open and normally closed dual contacts. |
|||||||||||
T4 |
4Point alarm relay output, the first 3 points are single normally open contacts, and the fourth point is a double contact of normally open and normally closed. |
|||||||||||
O1~O4 |
1Around 4 o'clockOCGate output (voltage should be less than 40V DC, current should be less than 40mA) |
|||||||||||
D |
T1~T2 |
1~2Point alarm relay output, 1-point normally open+normally closed dual contact; 1 point normally open contact |
||||||||||
T3 |
3Point alarm relay output, point 1 is a normally open+normally closed dual contact, and the other 2 points are single normally open contacts |
|||||||||||
O1~O3 |
1~3 o'clockOCGate output (voltage should be less than 40V DC, current should be less than 40mA) |
|||||||||||
E |
T1~T2 |
1~2Point alarm relay output, all with single normally open contacts |
||||||||||
O1~O2 |
1~2 o'clockOCGate output (voltage should be less than 40V DC, current should be less than 40mA) |
|||||||||||
Contact input (optional) |
K |
1External switch input for resetting |
||||||||||
Transmission (optional) (resolution: 1/3000; load capacity 600 Ω) |
A1 |
Current output (4-20) mA, (0-20) mA, (0-10) mA |
||||||||||
A2 |
Voltage output (0-5) V, (1-5) V |
|||||||||||
A3 |
Voltage output (0-10) V |
|||||||||||
A4 |
Voltage output (-5V~+5V) |
|||||||||||
A5 |
Voltage output (-10V~+10V) |
|||||||||||
External power supply (optional) |
B1 |
24V±5% 50mAbelow |
||||||||||
B2 |
12V±5% 50mAbelow |
|||||||||||
B3 |
10V±5% 50mAbelow |
|||||||||||
Communication (optional) (Communication protocol can be selected through instrument parameters: Modbus RTU or TC-ASCII protocol) |
S1 |
RS232interface(AH, AS, B sizes only) |
||||||||||
S2 |
RS485interface |
|||||||||||
Power specifications |
V0 |
100-240 V AC 50/60 Hz |
||||||||||
V1 |
10-24V AC 50/60 Hz;10-24V DC |
|||||||||||
Installation method |
—AP |
Disk mounted (E size only) |