WKT-A8 fully automatic Karl Fischer moisture analyzer
Brief description: The WKT-A8 fully automatic Karl Fischer moisture analyzer utilizes the principle of Karl Fischer Coulomb method (coulometric method
Product details
brand VICOMETER/VICOMETER application area Medical and health, environmental protection, agriculture, pharmaceuticals, comprehensive
measurement speed 40 μ g H2O/s (maximum) measuring range 0.01? μg? H2O to 260mg? H2O
electrolytic current 0-450mA adjustable Concentration unit %The ppm、mg/kg














WKT-A9精湛型卡尔费休水分测定仪_19.jpg

product overview

WKT-A8 fully automatic Karl Fischer moisture analyzerThe principle of Karl Fischer Coulomb method (coulometric method) is used to quickly determine trace moisture in samples. The moisture content can be measured as low as 1ppm (0.0001%), and the trace moisture of solids, liquids, and powders can be determined within 1 minute. The instrument has a built-in printing function and can store 600 sets of data, which can be queried and printed in real time!WKT-A8 fully automatic Karl Fischer moisture analyzerThe biggest feature is the ability to automatically add reagents and discharge waste liquids, which can avoid direct contact between operators and reaction reagents, as well as the impact of volatile components of reagents on the human body. The instrument complies with multiple national and international moisture determination standards and has four built-in moisture calculation formulas, which can meet the needs of moisture determination in various industries. It is widely used in industries such as chemical, petroleum, pharmaceutical, power, food, scientific research, and testing.

application area
liquid Chemical industry: products suitable for Karl Fischer method determination, such as alcohols, ethers, acids, benzenes, phenols, organic solvents, etc.
Petroleum and power industry: insulating oil, transformer oil and other oil products.
Pharmaceutical industry: pharmaceutical raw materials, etc.
Pesticide industry: emulsifiers, etc.
Other industries: lithium battery electrolytes, etc.
solid Solid substances with good solubility, such as various inorganic salts and citric acid
gas Nitrogen SF6、 Natural gas, liquefied gas, fluorocarbons, butadiene and other gases
The following industries require supporting card type heating furnaces for use
insoluble solid Lithium battery industry, plastic industry, medical industry, ceramic powder, metal powder, etc
Other insoluble solids Insoluble solids, easily contaminated and cross contaminated samples (lubricating oils, aldehydes and ketones), samples that easily react with Karl Fischer reagent, and samples with slow water release
Technical Parameter
PRODUCT MODEL WKT-A8
Measurement principle Karl Fischer Coulomb method (electricity method)
measurement speed 40 μ g H2O/s (maximum)
measuring range 0.01 μ g H2O to 260mg H2O
Measurement accuracy When the water content is between 100 μ g of water and 1000 μ g of water, the error is ≤± 2ug. When the water content is above 1000 μ g of water, the error is ≤± 0.2% (excluding injection error), and the standard deviation is ≤ 0.3%
Measurement resolution 0.1μg H2O
Water content (concentration range) 0.0001% -100% or 1ppm-106ppm
electrolytic current 0-450mA adjustable
Moisture concentration resolution 0.001
Concentration unit %The ppm、mg/kg
stirring speed Software control 0-40 adjustment
Drift value blank value deduction Automatic deduction
Special Features Automatic drift compensation, automatic deduction of environmental and background moisture, and fault self check prompt
Display and operation colorful touch screen
sample number Users can freely set the sample number
Store data 600 pieces
Printing function Built in low-energy high-speed thermal printer, 56mm paper width
print contents Display different contents based on user measurement formulas and measurement results
Calendar/Time Display and print out the current time, date, detection time, and date
End point indication Screen prompt/print output/sound warning/endpoint light indicator
Usage environment Temperature 2 ℃ -50 ℃, humidity ‹ 90%
Power consumption ≤50W
Host size 400mm*375mm*170mm
supply voltage 220V 50HZ 150W
weight The net weight of the host is 4kg, and after packaging, it is 7KG
Product Features

1. One click automatic addition of Karl Fischer reagent, one click automatic discharge of electrolytic cell waste liquid, and operators do not need to come into contact with the reagent

2. Environmental humidity detection, automatic deduction of environmental interference values, high sensitivity

3.4 formulas for calculating moisture content and 2 measurement methods to meet the requirements for determining moisture content in liquid, solid, and gas samples

4. Multiple data display methods: ug/ppm/percentage content/mg/L/sample name/experimental date, etc. Experimental record standards.

5. It can store up to 600 sets of data for you to retrieve and print at any time.

6. Our eternal pursuit is to import materials and components, and to ensure the stability, accuracy, and long service life of our instruments.

7. Optional USB or RS232 interface, can be connected to a computer PLC balance for automated management

8. The color touch screen operating system is like a mobile app that is easy and convenient to use, with built-in Chinese navigation and electronic manual.

9. Appearance*Design, electrostatic spraying process is environmentally friendly, easy to clean, and corrosion-resistant.

10. Built in Chinese and English languages, customizable for international friends to use.

11. Compliant with multiple national standards and applicable to various industries.

Applicable standards for WKT-A8

  • GB/T 6283-2008 Determination of moisture content in chemical products Karl Fischer method

  • ASTM E1064-2008 Karl Fischer Coulombic Titration for Determination of Water Content in Organic Liquids

  • GB/T 7600-1987 Determination of Moisture Content in Operating Transformer Oil (Coulombic Method)

  • ASTM D4928-00 (2010) Karl Fischer Coulombic Titration for Determination of Water Content in Crude Oil

  • ASTM D6304-2007 Karl Fischer coulometric titration method for determining water content in petroleum products, lubricants, and additives

  • ISO 10337-1997 Determination of Moisture in Crude Oil Karl Fischer Coulombic Titration Method

  • GB/T 11146-2009 Determination of Crude Oil Water Content Karl Fischer Coulombic Titration Method

  • GB/T 3727-2003 Determination of Trace Water in Ethylene and Propylene for Industrial Use

  • GB/T 5074-1985 Method for determination of moisture content in coking products by microcoulometry

  • GB/T 6023-2008 Determination of Trace Water in Butadiene for Industrial Use Karl Fischer Coulombic Method

  • GB/T 7376-2008 Determination of Trace Moisture in Fluoroalkanes for Industrial Use Karl Fischer Method

  • GB/T 18619.1-2002 Determination of Water Content in Natural Gas Karl Fischer Coulombic Method

  • GB/T 18826-2002 Industrial 1,1,1,2-tetrafluoroethane HFC-134a

  • SH/T 0246-1992 Determination of Water Content in Light Petroleum Products (Electricity Method)

  • SH/T 0255-1992 Method for determination of moisture content in additives and lubricating oils containing additives (electric method)

  • SH/T 1770-2010 Petrochemical Industry Standard of the People's Republic of China (Determination of Moisture Content in Plastic Polyethylene)

  • ASTM E1064-2008 Karl Fischer Coulombic Titration for Determination of Water Content in Organic Liquids

  • ASTM D4928-00 (2010) Karl Fischer Coulombic Titration for Determination of Water Content in Crude Oil

  • ASTM D6304-2007 Standard for Determination of Water Content in Petroleum Products, Lubricants, and Additives by Karl Fischer Coulombic Titration