Traditional Chinese Medicine Sulfur Dioxide Analyzer
The traditional Chinese medicine sulfur dioxide analyzer is a professional instrument used to detect the content of SO2 in Chinese medicinal materials
Product details
Details
The traditional Chinese medicine sulfur dioxide analyzer is a professional instrument used to detect the content of SO2 in Chinese medicinal materials or beverages. It uses voltammetry to detect the concentration of substances in solution, achieving the purpose of quantitative analysis of the test solution. In the process of electrochemical reactions, oxidation-reduction reactions occur, and we can control the rate of electron transfer to determine the concentration of the substance in the test solution. The core part is located in the electrolytic cell. The electrolyte in the electrolytic cell is phosphate, consisting of an external reference electrode and a working electrode. After adding the sample solution, under weak acid conditions, free sulfur dioxide is converted into sulfite and reacts with oxygen in the air to generate sulfate ions. Then, the potential change of sulfate ions generated is detected by an electrode measurement system to calculate the content of SO2 in the sample.
JT-ST107-1RW Traditional Chinese Medicine Sulfur Dioxide Analyzer Usage:
Detection of residual sulfur dioxide in traditional Chinese medicinal materials and decoction pieces in the 2015 edition of the Chinese Pharmacopoeia
Composition of JT-ST107-1RW Traditional Chinese Medicine Sulfur Dioxide Analyzer
It consists of four sets of heating control units, one set of built-in cooling water self circulation unit, four sets of nitrogen flow control units, four sets of magnetic stirring control units, timing control units, and titration units.
1.2 Heating control unit
1.2.1 The heating device adopts a bowl shaped far-infrared ceramic vessel suitable for round bottom flasks, with high thermal radiation efficiency, low power consumption, and a single hole heating power of 500W; The heating unit has 4 positions and can be independently controlled through a single hole, with adjustable heating power.
1.2.2 The heating area is equipped with insulation design to prevent heat loss and ensure uniform and stable heating of the sample.
1.2.3 The heating system is designed with micro boiling and full boiling control modes, which automatically control the heating rate according to different sample boiling points to ensure stable distillation experiments and controllable sample boiling phenomena.
1.3 Built in cooling water self circulating unit
Closed internal circulation reflux system, no need for external cooling water source, equipped with compressor refrigeration and air cooling dual refrigeration cooling internal circulation system, suitable for large-scale work, with better condensation effect.
The input power of the compressor should be 800W, and the cooling power should be 3000W.
1.4 Nitrogen flow control unit
1.4.1 The host should be equipped with a rotary flow meter that can adjust the nitrogen flow rate through a single hole, with a flow rate control range of 60-600ml/min.
1.5 Magnetic stirring control unit:
1.5.1 An independent built-in magnetic stirring device should be installed in the receiving area of each distillation unit, and the stirring speed can be adjusted by a knob.
1.6 Timing control unit:
1.6.1 According to the pharmacopoeia method, each distillation unit should be equipped with an independent timing control device, which can set a working time of 0-200 minutes. After the working time is set, it will automatically count down, and the power can be automatically turned off when the timing ends;
1.7 Titration unit
1.7.1 The host is equipped with an independent titration butterfly clip, which facilitates the fixation of the burette for titration.
Working conditions and environment for traditional Chinese medicine sulfur dioxide analyzer:
Power supply: AC220V,50Hz;
Environmental temperature: 10-35 ℃;
Environmental humidity:< 60%.
3. Product specification requirements
Heating unit: four positions;
Host size (mm): 960 × 575 × 426;
Time control: 0-200min;
Rated power: 3100W;
Heating time: 5-8 minutes;
Nitrogen flow rate: 60-600ml/min
4. System configuration
One main unit, one set of condenser tube fixing brackets, one set of 1000ml double necked glass flask placement racks, four reflux condenser tubes, four 1000ml double necked glass flasks, four 100ml triangular flasks, four glass bend tubes, four 50ml acid adding scale tubes, and several accessory parts.