TSQ ™ 8000 GC-MS/MS is a system designed to enhance the competitiveness of laboratories, accelerating the analysis cycle of samples while reducing analysis costs. This GC-MS/MS system provides high-performance selective reaction monitoring (SRM) through software use, improving the performance of triple quadrupole GC-MS/MS technology
Reliability and applicability.
gc-ms
The structural selectivity of SRM reduces interference from the matrix and other target compounds, allowing for rapid analysis of more compounds in a single analysis. Through the Thermo Scientific Trace Finder software, SRM can provide clean peak detection and automatic peak integration, and this solution allows users to spend less time adjusting peak integration and obtain result reports faster.
Timed Retention Time SRM (t-SRM)
When more compounds are added in a single run, the management of the collection window becomes more complex. The TSQ 8000GC-MS/MS system significantly reduces the complexity of this management by automatically optimizing the localization of specific compounds. Just enter the retention time and peak collection time, and t-SRM will automatically process everything else. This ensures that optimized compound detection can achieve maximum sensitivity, and more compounds can be added to the method without sacrificing the sensitivity of individual compounds. Before these compounds are eluted, the mass spectrometer will not waste resources scanning.
gc-ms
AutoSRM: A software designed for optimizing the settings of automated SRM method creation and full scan to complete analysis methods.
TSQ 8000 GC-MS/MS Instrument Method: Provides true timed SRM operation, providing high sensitivity and simplicity for complex SRM methods.
Industry leading linear detector
The Thermo Scientific DynaMax detection system on the TSQ 8000 system provides industry-leading linearity. This detector, combined with the low detection limit of SRM, makes the mass spectrometer the best quantitative system.
gc-msNo need to use helium gas
The selected collision gas is nitrogen or argon. No need to use expensive helium gas.
Remove ion source
The entire ion source can be completely disassembled without the need for vacuum, and the mass spectrometer includes a pre quadrupole surface. No need for wire connection or vacuum, reducing instrument cleaning
No need to clean or replace the quadrupole
The heating pre quadrupole protects the main quadrupole component, so the latter does not require cleaning or replacement.
Dual heating zone on ion source
Before cleaning the ion source, the dual independent heating zones on the TSQ 8000 system ensure thousands of injections of dirty substrates.
Double filament ensures longer running time
The intelligent dual filament design ensures longer operation time before the next maintenance.
second-handgc-ms, Thermo Fisher Scientific gas chromatography-mass spectrometry,
No noise is what it is; Okay; noise
The off-axis optics of the pre quadrupole of the curve effectively removes neutral noise, reduces background, and lowers detection limits.
The information of TSQ 8000 triple quadrupole gas chromatography-mass spectrometry is provided by Thermo Fisher Scientific. If you want to learn more about the quotation, model, parameters and other information of TSQ 8000 triple quadrupole gas chromatography-mass spectrometry, please feel free to call or leave a message for consultation.