TT260 Coating Thickness Tester
1、 Functional Features
The TT260 coating thickness gauge uses both magnetic and eddy current thickness measurement methods, which can non destructively measure the thickness of non-magnetic coatings (such as zinc, aluminum, chromium, copper, rubber, paint, etc.) on magnetic metal substrates (such as steel, iron, alloys, and hard magnetic steel) and non-conductive coatings (such as rubber, paint, plastic, anodized film, etc.) on non-magnetic metal substrates (such as copper, aluminum, zinc, tin, etc.).
Can use 7 types of probes (F400, F1, F1/90 ° F10、CN02、N1)
There are two measurement methods: Continuous measurement method and Single measurement method;
There are two working modes: Direct mode and Group mode (A-B);
There are five statistical measures: Mean (MEAN), Maximum (MAX), Minimum (MIN), Number of Tests (NO.), and Standard Deviation (S.DEV);
There are two methods to calibrate the instrument, and the basic calibration method can be used to correct the systematic error of the measuring head;
Storage function: capable of storing 495 measurement values;
It has a deletion function: it can delete individual suspicious data that appears during measurement, as well as all data in the storage area, in order to conduct new measurements;
Limits can be set: automatic alarms can be triggered for measurement values outside the limits; And a histogram can be used to divide a batch of measurement values
Analysis;
Printing function: capable of printing measurement values, statistical values, limits, histograms;
Capable of communicating with a PC: capable of transmitting measured and statistical values to the PC for data processing
One step processing;
Equipped with power undervoltage indication function;
There is a buzzing sound during the operation process;
It has an error prompt function, which provides error prompts through screen display or beeping sound;
There are two shutdown modes available: manual shutdown mode and automatic shutdown mode
This instrument meets the following standards: GB/T 4956-1985 Measurement of thickness of non-magnetic coatings on magnetic metal substrates Magnetic methods GB/T 4957-1985 Measurement of thickness of non-conductive coatings on non-magnetic metal substrates Eddy current methods JB/T 8393-1996 Magnetic and eddy current coating thickness measuring instruments JJG 889-95 "Magnetic resistance thickness gauge" JJG 818-93 "Eddy current thickness gauge"
IITT260 Coating Thickness TesterTechnical Parameter
Probe type | Optional, see attached table |
measuring principle | Magnetic induction and eddy current |
measuring range | Probe decision |
Low resolution limit | Probe decision |
Probe connection method | Split type wire connection (replaceable) |
Indication error | A little calibration (um) | Probe decision |
Two point calibration (um) | Probe decision |
Measurement conditions | Small curvature radius (mm) | Probe decision |
Small area diameter of the substrate (mm) | Probe decision |
Small critical thickness (mm) | Probe decision |
Temperature and humidity | 0~40℃ 20%RH~90%RH |
STATISTICS | Mean, MAX, MIN Test frequency (NO.), standard deviation (S.DEV) |
way of working | Direct method and group method (Appl) |
Measurement method | Continuous measurement method and Single measurement method |
Upper and lower limit settings | have |
Storage capacity | 495 measurement values |
Print/Connect Computer | Comes with a printer/can connect to a computer |
Shutdown mode | Manual and automatic |
power supply | 1/2 nickel hydrogen battery 5 × 1.2V |
External dimensions | 270×86×47mm |
weight | 530g |
TT260 Coating Thickness TesterOptional probe parameter table
Probe model | F400 | F1 | F1/90 | F10 | N1 | CN02 |
Working principle | magnetic induction | Eddy Current |
Measurement range (um) | 0-400 | 0-1250 | 0-10000 | 0-1250 (chrome plating on copper 0-40um) | 10-200 |
Low resolution (um) | 0.1 | 0.1 | 10 | 0.1 | 1 |
Indication error | A little calibration (um) | ±[3%H+1] | ±[3%H+10] | ±[3%H+1.5] | ±[3%H+1] |
Two point calibration (um) | ±[(1~3)%H+0.7] | ±[(1~3)%H+1] | ±[(1~3)%H+10] | ±[(1~3)%H+1.5] | - |
Measurement conditions | Small curvature radius (mm) | Convex 1 | Convex 1.5 | straightness | 10 | 3 | straightness |
Small area diameter of the substrate (mm) | ф3 | ф7 | ф7 | ф40 | ф5 | ф7 |
Small critical thickness (mm) | 0.2 | 0.5 | 0.5 | 2 | 0.3 | unlimited |
overburden matrix | Organic materials and other non-magnetic coatings (in compliance with:Paint, coating, enamel, porcelain enamel, plastic and anodizing treatment, etc) | Non magnetic non-ferrous metal coating(in compliance with:Chromium, zinc, aluminum, copper, tin, silver, etc) |
The thickness of the covering layer shall not exceed 100 µ m | The thickness of the covering layer exceeds 100 µ m | The thickness of the covering layer shall not exceed 100 µ m | The thickness of the covering layer exceeds 100 µ m |
Like iron and steel Equal magnetic metal | The diameter of the measured area is greater than 30mm | F400 probe 0-400 µ m F1 type probe 0-1250 µ m | F1 type probe 0-1250 µ m F10 type probe 0-10mm | F400 probe 0-400 µ m F1 type probe 0-1250 µ m | F1 type probe 0-1250 µ m F10 type probe 0-10mm |
The diameter of the measured area is less than 30mm | F400 probe 0-400 µ m | F400 probe 0-400 µ m F1 type probe 0-1250 µ m | F400 probe 0-400 µ m | F400 probe 0-400 µ m F1 type probe 0-1250 µ m |
Such as copper, aluminum Brass, zinc, tin Waiting for non-ferrous metals | The diameter of the measured area is greater than 5mm | N1 type probe 0-1250 µ m | Only used for N1 type probe with chrome plating on copper 0-40 µ m |
Plastic, printed circuit non-metallic substrate | The diameter of the measured area is greater than 7mm | - | - | CN02 probe 10-200 µ m |