The NTC TCHW (A) integrated temperature controller consists of two parts: heating and cooling. The TCHW (A) has precise temperature control and is widely used in industries such as injection molding, chemical engineering, rubber extrusion, reaction vessels, blow molding, etc. The TCHW (A) integrated temperature controller can achieve temperature switching to accelerate production progress, reduce energy consumption, improve product molding efficiency, suppress product defects, and reduce the production of defective products.
Product Features
There are two types of machine refrigeration: cold water and air cooling.
Zui is suitable for electric injection molding machines. It can supply both media and cold water simultaneously.
It has multiple alarm functions: reverse phase, insufficient media, insufficient water flow, low water temperature, high or low fluorine pressure, fan overload, compressor overload.
Technical specifications
model | TCHA-2-3L | TCHA-3-6L | TCHA-5-9L | TCHA-8-12L | TCHW-2-3L | TCHW-3-6L | TCHW-5-9L | TCHW-8-12L | |
Temperature range for media usage | 10℃~95℃ | 10℃~95℃ | |||||||
Cold water usage temperature range | 6℃~30℃ | 6℃~30℃ | |||||||
Cooling method | air-cooled | water-cooled | |||||||
Cooling capacity | KW | 8.1 | 12.2 | 16.8 | 23.4 | 8.1 | 12.2 | 16.8 | 23.4 |
KCAL/H | 7000 | 10000 | 14500 | 20000 | 7000 | 10000 | 14500 | 20000 | |
Heating capacity (KW) | 3 | 6 | 9 | 12 | 3 | 6 | 9 | 12 | |
Cold water tank capacity (Lr) | 29 | 29 | 29 | 85 | 59 | 65 | 65 | 116 | |
Compressor capacity (kw) | 1.73 | 2.25 | 3.75 | 6 | 1.73 | 2.25 | 3.75 | 6 | |
Fan power (kw) | 0.3 | 0.3 | 0.5 | 0.3*2 | |||||
refrigerant | R-22 or R407C | ||||||||
Cold water circulation pump | Motor power (kw) | 1.1 | 1.1 | 1.5 | 2.2 | 1.1 | 1.1 | 1.5 | 2.5 |
Maximum flow rate (Lr/min) | 117 | 117 | 183 | 183 | 117 | 117 | 183 | 183 | |
The maximum flow rate under the hopper (Lr/min) | 10L | 10L | |||||||
Media circulation pump | Motor power (kw) | 0.5 | 0.5 | 0.75 | 1.5 | 0.5 | 0.5 | 0.75 | 1.5 |
Maximum flow rate (Lr/min) | 50 | 50 | 75 | 4.5 | 50 | 50 | 75 | 4.5 | |
Maximum pressure (MPa) | 0.4 | 0.38 | 0.38 | 110 | 0.4 | 0.38 | 0.38 | 110 | |
Pipe diameter | Media Import and Export (Inch) | 3/8’’*2 | 3/8’’*2 | 3/8’’*4 | 3/8’’*4 | 3/8’’*2 | 3/8’’*2 | 3/8’’*4 | 3/8’’*4 |
Cold water inlet and outlet (Inch) | 3/4’’ | 1’’ | 1’’ | 1-1/4’’ | 3/4’’ | 1’’ | 1’’ | 1-1/4’’ | |
Cooling water inlet and outlet (Inch) | - | 3/4’’ | 1’’ | 1-1/2’’ | 1-1/2’’ | ||||
Water supply outlet (Inch) | 1/2’’ | 1/2’’ | 3/4’’ | 3/4’’ | 1/2’’ | 1/2’’ | 3/4’’ | 3/4’’ | |
Overflow outlet (Inch) | 1/2’’ | 1/2’’ | 3/4’’ | 3/4’’ | 1/2’’ | 1/2’’ | 3/4’’ | 3/4’’ | |
Weight (kg) | 320 | 320 | 320 | 420 | 280 | 300 | 360 | 420 | |
Total electrical capacity (kw) | 6.63 | 10.4 | 15.5 | 21.55 | 6.33 | 10.1 | 15 | 21 | |
supply voltage | AC380V,50Hz,3P | ||||||||
Alarm | Reverse phase, insufficient media, insufficient water flow, low water temperature, high or low fluorine pressure, fan overload, compressor overload | ||||||||
Dimensions L * W * H (mm) | Length (mm) | 1200 | 1200 | 1200 | 1760 | 1000 | 1000 | 1100 | 1300 |
Width (mm) | 700 | 700 | 700 | 850 | 650 | 700 | 700 | 700 | |
Height (mm) | 1522 | 1550 | 1530 | 1300 | 1200 | 1200 | 1420 | 1434 |