T2005 laser particle size analyzer
——Explore wide distribution particle testing!
Brief introduction
The T2005 fully automatic wet laser particle size analyzer has opened up a new field of wide distribution particle testing. By adopting advanced testing principles, unique calculation modes, and authoritative calibration methods, this instrument has outstanding advantages such as accurate test results, good test repeatability, and high resolution, making it the choice for wide distribution particle size testing.
Scope of Application
T2005 is widely used in cement, ceramics, pharmaceuticals, lotion, coatings, dyes, pigments, fillers, chemical products, catalysts, drilling mud, abrasives, lubricants, coal powder, silt, dust, cells, bacteria, food, additives, pesticides, explosives, graphite, photosensitive materials, fuels, ink, metal and non-metallic powders, calcium carbonate, kaolin, coal water slurry and other powdery materials.
3、 Main performance characteristics
Advanced testing principles:By adopting advanced converging light Fourier transform optical path, the limitation of lens aperture on scattering angle is overcome. In addition, the method of adding lateral and backward photodetectors is used to collect scattered light from different angles in all directions, effectively improving the accuracy of testing submicron level nanoparticles and ensuring the reliability of test results;
Superior discernment ability:By using Mie scattering principle and unconstrained free inversion software, real results can be obtained for any distribution of particle groups, effectively improving the practicality of the instrument;
Unique decentralized system:The wet dispersion technology, which combines ultrasound and stirring, ensures uniform and sufficient dispersion of the sample. Through an electromagnetic circulation pump, all particles of different sizes are evenly distributed throughout the entire testing channel, fundamentally ensuring accurate repeatability of wide distribution sample testing;
Convenient and efficient testing method:All testing steps are completed through computer control, and testers only need to operate the computer to end the entire testing process in an easy environment and obtain ideal test results; 2-3 pieces of data can be recorded within one second, and the entire testing process can be completed in a very short time to obtain ideal test results;
Fully automatic centering system:Adopting a precision four item hybrid stepper motor, the optical path is automatically adjusted and the optical path is calibrated at any time, eliminating the trouble and difficulties caused by manual alignment of the optical path. At the same time, it also improves the accuracy and stability of the test results from an optical perspective;
Comprehensive data analysis:Comprehensively analyze the test data, automatically eliminate negative results, and comprehensively process the test results, eliminating the hassle of manual data processing and making the test results more representative.
Rich and intuitive data output:The software that matches this instrument is simple and intuitive to operate. It not only allows dynamic detection of samples, but also has powerful data processing and output functions. Users can choose different display modes (such as particle size distribution data tables, histograms, and curves) and different formats (BMP image files, Txt documents, Word documents, Excel documents, etc.) for particle size analysis reports according to their needs and habits;
Testing standards:By using various micrometer, submicron, and nanometer particle size standard materials, the instrument is calibrated and calibrated across the entire range, ensuring that particles of different sizes and distributions within its measurement range can obtain true and accurate test results. The test results have strong comparability and high reliability with similar foreign instruments.
4、 Technical parameters
Specification and model T2005A T2005B
Execution standards ISO13320-1:1999,GB/T19077.1-2008,Q/0100JWN001-2013
Range 0.01-780μm 0.1-1000μm
Number of detector channels 77 66
Accuracy Error <1% (D50 value of national standard sample)
Repeatability error <1% (D50 value of national standard sample)
Laser parameters Main laser source: High performance He Ne laser with λ=632.8nm and p>2mW
Auxiliary laser source: semiconductor laser, λ= 650nm,p>2mW
dispersion method ultrasonic Frequency: f=40KHz, Power: p=35W, Time: ≥ 1S
stir Speed: 0-3000rpm, adjustable speed
cycle Rated flow rate: 8L/min Rated power: 10W
Sample Cell Capacity: 350mL
MODE Software operation/fully automatic operation mode can be switched
Automatic centering system Fully automatic centering system
FUNCTION Analysis Including free distribution, R-R distribution, lognormal distribution, and hierarchical statistical models, it meets the different requirements of different industries for the statistical methods of particle size of the tested samples.
Statistical method Volume distribution and quantity distribution to meet different statistical methods for particle size distribution in different industries.
Statistics Comparison Statistical comparative analysis can be conducted on multiple test results, which can significantly compare the differences in test results between different batches of samples, samples before and after processing, and at different times. This has strong practical significance for industrial raw material quality control.
Custom Analysis User defined analysis parameters, calculated as percentages based on particle size, percentages based on particle size, or percentages based on particle size ranges, to meet the characterization requirements of different industries for particle size testing.
test report The test report can be exported to Word Excel、 Various forms of documents, such as images (Bmp) and text (Text), are available for viewing test reports and referencing test results in scientific articles in any situation.
Multi-Language Support Chinese and English language interfaces are supported, and other language interfaces can also be embedded according to user requirements.
Intelligent operation mode Equipped with intelligent operation mode, it can automatically control the steps of water inlet, dispersion, testing, etc., which not only reduces the workload of testing personnel, but also improves the repeatability of test results due to no human interference.
test speed <2min/time
volume 850mm*390mm*450mm
weight 40Kg
5、 Product Features
1. Large scale program design: The upper limit of the test can reach 780 microns, using dual laser orthogonal beam technology, and the lower limit of the test can be lowered to 0.05 microns.
2. Intelligent operation mode, supporting one click operation. Click on "Auto Test", then follow the prompts to add the sample, and all other operations will be automatically completed. Not only does it reduce the workload of testers, but it also eliminates interference errors caused by human factors.
3. The optical path automatic centering system is composed of a precision four phase hybrid stepper motor, with micro motion accuracy reaching the micrometer level, ensuring that the instrument's optical path is always in good condition.
4. Adopting a fully built-in decentralized system: using a high-power circulation pump to optimize the pipeline design, achieving a high level of overall control coordination and effectively preventing secondary sedimentation of large particles.
5. Unrestricted free fitting technique: Unrestricted free fitting technique, particle size analysis is not limited by any function and can truly reflect the distribution state of particles.
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!