Shanghai Huile Electric Co., Ltd
Home>Products>Single-phase reactive power meter
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    1881753568318321031365
  • Address
    No. 95 Shihuxin Road, Shihudang Town, Songjiang District, Shanghai
Contact Now
Single-phase reactive power meter
Single-phase reactive power meter
Product details
  • Single-phase reactive power meter
Detailed Introduction



varmeter

Function and Features:
1. The display magnification, communication address, baud rate, etc. can be set through the buttons on the panel, making it very flexible and convenient to use.
2. Optional analog output, with outputs ranging from 4 to 20mA, 0 to 12 to 20mA, etc.
3. Two optional alarm outputs are available to monitor the upper and lower limits of the measured parameters.
4. Optional RS-485 digital interface, using standard MODBUS-RTU protocol.
5. Optional 2-channel switch input, capable of monitoring the switch status within the system.
6. Digital zeroing and tuning, high precision, and extremely cost-effective.

1not haveTechnical specifications of power meter

accuracy class

Display accuracy: Level 0.5

display

Four digit LED digital display

input

Nominal input

Current AC1A, AC5A, DC1A, DC5A, DC20mA, etc;
Voltage AC100V, AC220V, AC380V, DC100V, DC220V, DC380V, DC75mV, etc
(Range can be extended through CP or PT, please specify when ordering)

overload

Continuous: 1.2 times, instantaneous: current 10 times (5 seconds), voltage 2 times (10 seconds)

frequency

50/60Hz±10%

power supply

Auxiliary power supply

The auxiliary power supply comes standard with AC220V and can be optionally AC/DC 80-265V

power consumption

<4VA

Isolation and voltage resistance

The power supply, input, transmission output, and communication interface are AC2kV, and the input, transmission output, and communication interface are AC1kV

insulation resistance

≥100MΩ

Mean time between failures

>50000h

working conditions

Environmental temperature: -10~55 ℃, relative humidity ≤ 93%, no corrosive gas field, altitude ≤ 2500m

Output (optional)

Analog quantity (M)

DC4~20mA/0~20mA

Digital Communication (C)

RS-485 interface, MODBUS-RTU protocol, waveform rate default 9600 (optional 4800, 9600) bps

Switching input (K)

2-channel switch input, dry node mode

Alarm output (J)

2-channel switch alarm output, relay contacts