Multi functional power meters use advanced microprocessors and digital signal processing technology. Through direct AC sampling, they can measure electrical parameters such as current, voltage, active power, reactive power, power factor, frequency, active energy, and reactive energy. They can also be equipped with switch input output, analog transmission output, power pulse output, and RS485 network communication functions. As an advanced intelligent and digital front-end acquisition component for power grids, this instrument is widely used in various control systems, industrial automation, intelligent buildings, intelligent distribution panels, and switch boxes. It has the characteristics of easy installation, simple wiring, easy maintenance, small engineering quantity, and programmable input parameters on site. Capable of networking different PLCs and industrial control computer communication software in the industry.
overview
Multi functional power meters use advanced microprocessors and digital signal processing technology. Through direct AC sampling, they can measure electrical parameters such as current, voltage, active power, reactive power, power factor, frequency, active energy, and reactive energy. They can also be equipped with switch input output, analog transmission output, power pulse output, and RS485 network communication functions. As an advanced intelligent and digital front-end acquisition component for power grids, this instrument is widely used in various control systems, industrial automation, intelligent buildings, intelligent distribution panels, and switch boxes. It has the characteristics of easy installation, simple wiring, easy maintenance, small engineering quantity, and programmable input parameters on site. Capable of networking different PLCs and industrial control computer communication software in the industry.
TECHNICAL INDEX
transport enter measure measure apparent show |
electricity press |
RATING |
AC100V, 400V (please specify when ordering) |
overload |
Duration: 1.2 times Instantaneous: 2 times/10 seconds |
power consumption |
< 1VA (per phase) |
impedance |
>500KΩ |
accuracy |
RMS measurement, accuracy level 0.5 |
electricity flow |
RATING |
AC 1A, 5A (please specify when ordering) |
overload |
Duration: 1.2 times Instantaneous: 10 times/10 seconds |
power consumption |
< 0.4VA (per phase) |
impedance |
<2MΩ |
accuracy |
RMS measurement, accuracy level 0.5 |
frequency |
45-55Hz、 Precision 0.01 Hz |
power |
Total harmonic content of voltage and current (2-31st harmonic content) |
electric energy |
Positive and negative active and reactive energy measurement |
display |
Programmable, switchable, looping (LED/LCD) display |
Electric energy display range |
0.01-KWh (or KVar) |
power supply |
scope of work |
AC/DC 80-270V special requirements can be customized |
power consumption |
<5VA |
input |
Switching input |
4-channel switch input, remote dry contact mode (optional) |
output |
Digital Interface |
RS-485, MODBUS-RTU protocol (optional) |
Switching Output |
4-channel switch output, relay passive contact mode (optional) |
analog output |
4-channel analog transmission output, 4-20mA/0-20mA/4-12-20mA/0-5V/1-5V (optional) |
environment |
work environment |
-10-55 ℃, relative humidity<85%. Non corrosive gas environment, altitude<2000m |
Environment |
-55-85 ℃, relative humidity<85% |
secure |
pressure resistance |
Input/power>2KV, input/output>2KV, power/output>1KV |
isolation |
Input, output, and power supply to the chassis>100M Ω |
List of models and functions of single-phase multifunctional power meters
model |
measure |
display |
Appearance and installation dimensions |
Peripheral functions (optional, to be specified when ordering) |
A |
B |
C |
D |
E |
digital communication |
Switch Module |
Transmission output |
HL-42K1E |
U、I、KW、KVar、KWh、 KVarh、Hz、cosφ |
LED
|
120
|
120
|
83
|
112
|
112
|
RS-485 MODBUS -RTU |
4-way entry Route 4 departs 4DI/4DO |
4-channel transmission 4-20mA 0-20mA 4-12-20mA 0-5V 1-5V (Optional) |
HL-42K1EY |
U、I、KW、KVar、KWh、 KVarh、Hz、cosφ |
LCD |
120
|
120
|
83
|
112
|
112
|
HL-96K1E |
U、I、KW、KVar、KWh、 KVarh、Hz、cosφ |
LED
|
98
|
98
|
83
|
90
|
90
|
RS-485 MODBUS -RTU |
4-way entry Route 4 departs 4DI/4DO |
4-channel transmission 4-20mA 0-20mA 4-12-20mA 0-5V 1-5V (Optional) |
HL-96K1EY |
U、I、KW、KVar、KWh、 KVarh、Hz、cosφ |
LCD |
98
|
98
|
83
|
90
|
90
|
HL-80K1E |
U、I、KW、KVar、KWh、 KVarh、Hz、cosφ |
LED
|
84
|
84
|
83
|
76
|
76
|
RS-485 MODBUS -RTU |
2-channel switch Quantity output |
4-channel transmission 4-20mA 0-20mA 4-12-20mA 0-5V 1-5V (Optional) |
HL-80K1EY |
U、I、KW、KVar、KWh、 KVarh、Hz、cosφ |
LCD |
84
|
84
|
83
|
76
|
76
|
HL-72K1E |
U、I、KW、KVar、KWh、 KVarh、Hz、cosφ |
LED
|
75
|
75
|
90
|
67
|
67
|
RS-485 MODBUS -RTU |
2-channel switch Quantity output |
4-channel transmission 4-20mA 0-20mA 4-12-20mA 0-5V 1-5V (Optional) |
HL-72K1EY |
U、I、KW、KVar、KWh、 KVarh、Hz、cosφ |
LCD |
75
|
75
|
90
|
67
|
67
|
HL-45K1E |
U、I、KW、KVar、KWh、 KVarh、Hz、cosφ |
LED
|
50
|
50
|
83
|
45
|
45
|
RS-485 Or 2-channel transmission output |
Route 2 departs 2DO |
RS-485 Or 2-channel transmission output |
HL-45K1EY |
U、I、KW、KVar、KWh、 KVarh、Hz、cosφ |
LCD |
50
|
50
|
83
|
45
|
45
|
HL-48K1E |
U、I、KW、KVar、KWh、 KVarh、Hz、cosφ |
LED
|
51
|
99
|
83
|
91
|
45
|
Route 2 departs 2DO |
RS-485 Or 2-channel transmission output |
HL-48K1EY |
U、I、KW、KVar、KWh、 KVarh、Hz、cosφ |
LCD |
51
|
99
|
91
|
45
|
45
|
Wiring example diagram
Note: 1 "★" is the current input terminal. Please refer to the product's random wiring diagram for specific wiring methods and parameters.
Order List
When placing an order, please specify in detail the required model, input signal ratio, and expansion function module.
Example 1: Model: HL-42K1E
Power supply: AC220V
Input: 10KV/100V, 200A/5A
Communication: RS485/MODBUA-RTU
Function extension: 4DI/4DO
Quantity: 88 units