Beijing Huilong Huanke Environmental Instrument Co., Ltd
Home>Products>SensION+MM150 portable multi parameter water quality analyzer
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    206, Building 14, Xilu South Street, Liangxiang, Fangshan District, Beijing
Contact Now
SensION+MM150 portable multi parameter water quality analyzer
SensION+MM150 portable multi parameter water quality analyzer, portable multi parameter water quality laboratory, Hash from the United States, SensION
Product details

SensION+MM150Portable multi parameter water quality analyzer - Huilong Environmental Science Co., Ltd. 010-59483667

Popular keywords:SensION+MM150 portable multi parameter water quality analyzerSensION+MM150, Portable multi parameter water quality analyzer, Hash from the United States, Hash General Agent, Huilong Huanke
SensION+MM150Portable multi parameter water quality analyzerDetailed introduction:
Ergonomic handheld design, lightweight and portable with a large LCD screen and navigation menu, making operation easier: The size of the LCD display screen is 50 × 66 (visible area: 46 × 62) mm.
IP67 waterproof and seismic design, safer to use
Over 1000 hours of battery life and 6 million button cycles, durable and reliable
Rich electrode options to meet different application needs; There are also 4-in-1 electrodes to adapt to constant changes!
An indicator of measurement time - electrode health and maintenance schedule - can be displayed on the user interface.
Two measurement modes: stable measurement or continuous measurement.
5 laminated buttons, made of PET that has undergone protective treatment.
Alkaline battery: 3AA × 1.5V
Waterproof MP-5 and MP-8 connectors, suitable for portable electrode use.
MP-5: For PH1, Use of EC5 and DO6 electrodes: (IP67)。
MP-8: For use with MM110 and MM150 electrodes: (IP67)。
Instrument operation manuals in multiple languages: English, Spanish, French, Portuguese, Chinese.

SensION+MM150Portable multi parameter water quality analyzerProduct model and function:


PH analyzer
EC tester
Dissolved oxygen analyzer
Multi parameter measuring instrument
PH1
EC5
DO6
MM110
MM150
MM156
pH, temperature&ORP
PH range:-2.00-19.00
ORP range:±2000mV
Temperature range:-20-150℃(-4~302℉)
0-50℃
Automatic buffer recognition(5 buffer solutions 2.00, 4.01, 7.00, 9.21, and 10.01)
-Manual or default input
ORP calibration
EC
EC range:0.00-500.0mS/cm (automatic range selection)
TDS range:0-200g/L (automatic range selection)
Salinity range:0.0-50.0g/L
Can be carried out1, 2, 3 point conductivity calibration
-Standard value:147,1413μS/cm, 12.88, 111.8mS/ cm@25 ℃
-Manual or default input
Temperature compensation (throughPt1000 sensor for automatic compensation
Selectable temperature coefficient(0-9.99%/℃); The reference temperature is 20 or 25 ℃
TDS conversion factor (inOptional between 0-4.44; The default value is 0.64)
dissolved oxygen
Dissolved oxygen range:0.00-19.99, 20.0-26.0mg/L
%Saturation range:0.0~199.9,200~260%
Temperature compensation (through built-in)NTC performs automatic compensation)
Pressure compensation (automatic or manual input)
Salinity compensation (automatic or manual input)
Dissolved oxygen calibration (performed in the calibration chamber)1 or 2 points, 0 or 100% calibration)
Other features
Can display measurement time
Can simultaneously read multiple parameter readings
Measurement mode: stable measurement or continuous measurement
Re adjustment of temperature



sensION+Portable electrochemical analyzerOrdering Guide:


SensION+PH1
PH/mv,℃
Basic type(Universal) pH on-site testing component
LPV2550T.97.002
5050T PH temperature
Suitable for general water quality analysis
superiorOn site pH testing component for dirty water samples
LPV2551T.97.002
5051T pH temperature
Suitable for measuring water samples with high solid content and viscous media
superiorPH on-site testing component for difficult to measure samples
LPV2552T.97.002
5052T PH temperature
Suitable for low ionic strengthColloidal, milky, and paste like samples
Basic typeORP on-site testing components
LPV2555.97.0002
5055 ORP
Suitable for chemical waste treatmentElectroplating tank and typical water quality analysis
SensION+MM110 can be connected to multi parameter electrodes
superiorPH&ORP multi parameter testing component
LPV2645.97.0002
5045 PH ORP temperature
Suitable for general water quality analysis
SensION+EC5
conductivityTotal dissolved solids, salinity,
Basic conductivity field testing component
LPV3560.97.0002
5060 conductivity temperature
Suitable for general water quality analysis
Superior on-site conductivity testing components
LPV3562.97.0002
5062 conductivity temperature
Suitable for measuring media that are difficult to measure
SensION+DO6
dissolved oxygenSaturation,
Basic dissolved oxygen on-site testing component
LPV4551.97.0002
5120 dissolved oxygen temperature
Suitable for general water quality analysis
SensION+MM150
PH/mv, conductivityTotal dissolved solids, salinity
superiorPH and conductivity multi parameter on-site testing component
LPV4059.97.0002
5059pH conductivity temperature
Suitable for agriculture and general water quality analysis
superiorpH, Conductivity&ORP multi parameter on-site testing component
LPV4048.97.0002
5048pH conductivityORP temperature
Suitable for measurement in sewage treatment and general water quality analysis


SensION+MM150Portable multi parameter water quality analyzerHash China's General Agent, Huilong Huanke's General Agent
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!