Core parameters of S2 RANGER energy dispersive X-ray fluorescence spectrometer
Instrument Introduction:
S2 RANGER is a newly designed energy dispersive X-ray fluorescence spectrometer by Brooke AXS GmbH in Germany, which can analyze powders, solids, liquids, coatings, slurries, films, and cutting materialsCutting various types of samples, with element determination ranging from 6C-92U and content ranging from ppm-100%. The fully upgraded S2 RANGER adopts the fifth generation XFlash SDD silicon drift detector,Active area20mm2No need for liquid nitrogen, resolution less than 139eV @ MnKa 100Kcps. Even when the counting rate reaches 250Kcps, the resolution does not decrease. Easy to learn through intuitive touchscreen control operation. Automatic sampler, calculationThe machine, touch screen, printer, and vacuum pump are fully integrated together, occupying minimal space. There is only one power interface, no cables, hoses, etc., making instrument installation and movement very convenient. When measuring liquid or loose powder samples, the method of first vacuuming and then flushing with helium gas is repeated. The advantage is that the air is quickly expelled, the consumption of helium gas is low, and the measurement can be selected according to the degree of sample volatilization in atmospheric pressure helium gas or reduced pressure helium gas mode.
Technical parameters:
Technical Parameter
Element range: 6 carbon~92 uranium
Concentration range: ppm ~ 100%
Sample types: loose powder, solid, and liquid
Sample size: Liquid, loose powder: up to 50 milliliters
Solid: diameter 40mm, for automatic sampler
Solid: diameter 75mm, for manual injection
Sample preparation: direct injection, sample cup, powder pressing, glass melting
Automatic sampler: 28 position automatic sampler
(Option) Continuous injection
Maximum diameter 40mm, maximum height 40mm, maximum sample weight 200g
TouchControl: Integrated 12 inch TFT touch screen
X-ray tube: Pd target
Maximum power: 50W, maximum voltage: 50 kV, maximum current: 2mA
Primary optical path filter: 9-position automatic filter changer
Detector: XFlash SDD silicon drift detector
Resolution:< 139 ev@='' mn='' ka='' 100,='' 000='' cps=''>139>
Peltier cooling (does not require liquid nitrogen)
Vacuum pump: built-in integration
Helium flushing system: built-in integration; Need helium gas supply
Measurement mode: Vacuum: Solid sample
Helium: liquid and loose powder
Air: Ti22 and above elements
Printer: Built in integrated thermal printer
Network: Built in modem and Ethernet interface
Automation: Supports LIMS data exchange
Power supply: 110/240 V, 50/60 Hz, maximum power consumption 1 kVA
External cooling water: not required
Size: 65 cm x 80 cm x 60 cm, 96 kg
(Height x Width x Depth, Weight)
Quality Assurance and Safety: DIN EN ISO 9001:2000
CE Electrical Safety Certification
Complies with the provisions of EN954-1 standard "Safety Category No. 3" and DIN 54113 standard
Main features:
It can perform qualitative, quantitative, and standard free quantitative analysis on solid, powder, and liquid samples, with an element range of 6C-92U and a content range of ppm to 100%.
Through intuitive TouchControl operation, it is easy to learn and even people without computer operation experience can apply it freely. With simple training, high-quality analysis results can be obtained.
The automatic sampler, computer, touch screen, printer, and vacuum pump are fully integrated together, occupying minimal space,
Pd/Ag target X-ray tube, maximum power 50W, maximum current 2mA, maximum voltage 50kV, equipped with 9-position primary optical path filter.
The fourth generation XFlash SDD silicon drift detector adopts Peltier cooling technology, does not require liquid nitrogen, and has no consumption. The resolution is better than 139eV @ MnKa 100Kcps, and even at counting rates as high as 250Kcps, the resolution does not decrease.
Advanced DuraBeryllium ™ The technical detector window film is sturdy, leak free, pressure resistant, completely maintenance free, and has no consumption in the later stage.
There are two designs: a 1-position sampler and a 28 position fully automatic sampler, which are suitable for fully automatic analysis of small and large quantities of samples per day.
Real time display of the status of the automatic sampler on the touch screen, allowing for easy loading and unloading of samples without causing confusion. Real time display of spectral line signals and the status of each component
There are four operating modes: atmospheric (>Ti), vacuum, basic helium (high volatility sample), and auxiliary helium (low volatility sample).
RoHS QUANT software, in response to RoHS&WEEE EU directives, directly measures harmful elements such as Cd, Pb, Hg, Cr, Br, etc., with a detection limit of less than 5ppm.
Single power interface, easy and fast installation.
Size: 65cm x 80cm x 60cm, 80kg (height x width x depth, weight).
Applications: metallurgy, petroleum, chemical industry, machinery, electronics, household appliances, ceramics, cement, building materials, geology, minerals and other fields.