Features:
1. Integrated 4-20mA signal and RS-485 signal output function
2. Digital display concentration
3. Infrared remote control operation zero calibration
4.4-20mA signal calibratable
5. Three chamber isolation, high protection level, better safety
Detection principle catalytic combustion type |
Detection object methane |
Detection method diffusion type |
Resolution 1% LEL |
Detection range 0-LEL |
Detection error ± 5% LEL F.S |
Response time ≤ 30 seconds |
Working mode: Long term continuous work |
Protection level 1P66 |
Power consumption ≤ 2W |
Display Method: Digital Display |
Operating environment temperature: -40 ℃~+70 ℃ |
Rated power supply voltage 24V DC |
Humidity: 10%~93% RH |
Output signal 4-20mA standard/RS-485 standard signal output | |
1. Integrated 4-20mA signal and RS-485 signal output function
2. Digital display concentration
3. Infrared remote control operation zero calibration
4.4-20mA signal calibratable
5. Three chamber isolation, high protection level, better safety