VIP member
Programmable Salt Spray Test Chamber CZ-60B/CZ-90B/CZ-120B
The salt water spray test is to test the corrosion resistance of the products after the surface of various materials has undergone anti-corrosion trea
Product details
The salt water spray test is to test the corrosion resistance of the products after the surface of various materials has undergone anti-corrosion treatment such as electroplating, anodizing, spraying, and antirust oil.
Execution standards and testing methods
- GB/T 2423.18-2000 Alternating Salt Spray Test Method
- GB/T 6461-2002 Grade Evaluation
- ASTM.B117-2009 Salt Spray Test
- JIS H8502 Salt water spray test method
- IEC 60068-2-11:1981 Salt spray test
- IEC 68-2-52 1996 Salt Spray Test
- GB/T 6461-2002 Salt Spray Test Evaluation Criteria
- ISO 9227-2006 Salt water spray test method
- GB/T 12967.3-91 CASS Accelerated Acetate Salt Spray Test
- QB/T 3828-1999 Copper Salt Accelerated Acetic Acid Salt Spray Test
- GB/T 5170.8-2008 Salt Spray Test Equipment Inspection Method
- GB/T 5170.11-2008 Inspection Methods for Corrosion Gas Testing Equipment
- GJB 150.11A-2008 Salt Spray Test Method
- GB/T 2423.17-2008 Salt Spray Test Method
- GB/T 10587-2006 Technical Conditions for Salt Spray Test Chamber
- CNS 8886-2002 Determination of Salt Spray Corrosion Degree
- CNS 4159 Copper acetate brine spray test method
- CNS 4158 Salt water spray test method
specifications
model | CZ-60B | CZ-90B | CZ-120B | CZ-160B | CZ-200B | ||||
---|---|---|---|---|---|---|---|---|---|
Indoor box size (cm) | 60x45x40 | 90x60x50 | 120x80x50 | 160x100x50 | 200x120x60 | ||||
Test box size outside the laboratory (cm) | 107x60x118 | 141x88x128 | 190x110x140 | 230x130x140 | 270x150x150 | ||||
Laboratory temperature | Saltwater test method (NSS ACSS) 35 ℃± 1 ℃/Corrosion resistance test method (CASS) 50 ℃± 1 ℃ | ||||||||
Pressure bucket temperature | Saltwater test method (NSS ACSS) 47 ℃± 1 ℃/Corrosion resistance test method (CASS) 63 ℃± 1 ℃ | ||||||||
Salt water temperature | 35℃±1℃ 50℃±1℃ | ||||||||
Laboratory capacity | 108L | 270L | 480L | 800L | 1440L | ||||
Salt water tank capacity | 15L | 25L | 40L | 40L | 40L | ||||
brine concentration | Add 0.26 grams of copper chloride (CuCl2 2H2O) per liter to a concentration of 5% sodium chloride solution or 5% sodium chloride solution | ||||||||
Compressed air pressure | 1.00±0.01kgf/cm2 | ||||||||
Spray amount | 1.0~2.0ml/80cm2/h (Collect for at least 16 hours and take the average) | ||||||||
Relative humidity in the laboratory | Over 85% | ||||||||
PH value | 6.5~7.2 3.0~3.2 | ||||||||
spray mode | Programmable spray (including continuous spray and intermittent spray) | ||||||||
power supply | AC220V1Φ10A | AC220V1Φ15A | AC220V1Φ20A | AC220V1Φ20A | AC220V1Φ30A |