Precision oven
The precision oven is designed for aging, drying, and baking semiconductor devices that require a dust-free space. It is integral, with supporting fee
Product details

The precision oven is designed for aging, drying, and baking semiconductor devices that require a dust-free space. It is integral, with supporting feet, and easy to move. The workshop of the drying oven is made of stainless steel material and filled with environmentally friendly aluminum silicate fiber cotton in the middle, which is durable. It uses high-efficiency and energy-saving heaters, a reasonable air blowing system, and a complete control system to make the temperature of the workshop more uniform. Adopting a dual digital temperature controller, it is eye-catching and intuitive,PIDAccurate temperature control, no temperature shock phenomenon. Equipped with timed control function and secondary over temperature protection function. The control box is located on the upper part of the machine for easy operation. Front air outlet method addedHEPAFilter, ensure cleanliness100Grade.

1、 Main technical parameter indicators (this performance indicator can be set at an ambient temperature of)+5~+35 ℃ measurement):

a)Box Structure

L Dimensions: Height1910mmwide1000mmdeep1400mm

Studio size: high1000mmwide800mmdeep800mm

Shell material: cold-rolled steel plate1.2mmTSpray colorRAL-7035colour

Studio material: stainless steelSUS304 1.2mmTMirror surface

Material of air duct: stainless steelSUS304 1.0mmTMirror surface

Thermal insulation material: using aluminum silicate fiber insulation cotton, effectively preventing heat loss

Insulation thickness:100mm

Sealing method: compression type, heat-resistant silicone rubber sealing strip

Door opening method: single door opening

Layered:8Layer, configuration8Layered shelf, stainless steel strip bottom10mmupper6mm

b)Specification

Temperature range: room temperature+20℃~150℃

Temperature regulation resolution (monitor)0.1

Temperature control accuracy:±0.3

Temperature fluctuation: ≤±1

Temperature uniformity: ≤±1 When in an empty state and at a constant temperature,9Point testing method);

Surface temperature rise of the box: the surface temperature is not greater than the room temperature plus20

Cleanliness:100level

Wind transport method: horizontal wind transport

Heating time: up to150Approximately at ℃30Within the classification range

Cooling time:100℃ drops to40Approximately at ℃40Within the classification range

c)Power

Power supply: 380V/50HZ(Three-phase four-wire)

Heating power:9KW

Blast power:1100W

Exhaust fan:250W

d)blower system

Wind transportation method:Horizontal circulation air supply on both sides

L blower motor:Long axis temperature resistant and low-noise centrifugal motor1100W/380V/4P

Impeller: Multi blade high-temperature resistant stainless steel impeller

L exhaust outlet: top

Air inlet: right side

e)control system

Control method:PIDadjustSSRcontrol

Temperature controller: Yudian digital display programming temperature control instrument/microcomputerP.I.DAutomatic calculation,pv/svDual display button setting

Temperature sensor:KThermistor, accurate temperature measurement

Timer:DHC7B(100hour)When the timer is up, cut off the power

L Overtemperature protection:Temperature control instrument; Cut off the heating power supply due to overheating

f)Security device

Circuit breaker switch (to prevent overcurrent and short circuit)

Fan overheating protection (protects the supply fan to prevent excessive fan temperature)

Overtemperature protection (preventing the studio temperature from being too high and protecting the product)

g)INSTALLATION REQUIREMENTS

The distance between the front of the oven and the wall shall not be less than700mmThe left and right rear sides shall not be less than500mmThe user must provide an independent distribution switch and be responsible for connecting the external power supply of the equipment.

Normal working environment conditions:

1. Temperature:5℃~45℃;

2. Relative humidity: not greater than85%

3. There is no strong vibration or airflow around;

Online inquiry