By using sensors to convert the magnitude of melt/fluid pressure into electrical signals (such as mV, mA, V) for output, it can be used by other devices in the control system (such as pressure control instruments, frequency converters, PLCs, etc.) to achieve open-loop or closed-loop automation control of the entire system.
High quality sensors, strict calibration processes, and sophisticated assembly techniques ensure the excellent quality of this product. Suitable for measuring and controlling the pressure of high-temperature melts/fluids in chemical fiber spinning, polyester, rubber and plastic machinery at temperatures ranging from 100 ℃ to 458 ℃. The PT series sensors can be used in conjunction with our PY series instruments to meet various requirements of different users, and can also be directly used with imported instruments (such as DYNISCO) without any adjustment or modification. The connection threads, lead out connectors, and other components are all compatible. Build a foundation to meet various customer needs.
Main technical parameters
Range
0~60(MPa)(The range can be customized according to the actual needs of the user)
Ultimate Overload
200%FS
Comprehensive accuracy
0.5%FSThe1.0%FS
response time
5 mS(rise to90%FS)
output signal
analog quantity 4~20mA(two-wire system)、0~5V、0~10V(three-wire system) 2.0MV/V(four-wire system)
load resistor
Maximum current output type800ΩVoltage output type greater than50KΩDigital output based on the actual mounting capacity of the chip
power supply voltage
24DCV(9~36DCV)
insulation resistance
greater than2000MΩ (100VDC)
medium temperature
0~200~500℃within
Sealing grade
IP65
ambient temperature
room temperature(-20~85℃)
Long term stability performance
0.1%FS/year
Zero temperature drift
≤±0.05%FS℃
Vibration impact
At the frequency of mechanical vibration20Hz~1000HzInternally, the output change is less than0.1%FS
temperature drift
≤±0.05%FS℃
electrical interface
Tightening nut, four flexible and thick core shielded wire, Hirschman plug, etc
compensation temperature
060℃
Mechanical connection (threaded interface)
G1/2TheM22×1.5TheM22×1.5Wait, other threads can be designed according to customer requirements
Safe overload
150%FS
Overall dimensions
Based on actual dimensions
| Example of Selection Guide for High Temperature Melt Pressure Sensor (Complete Model: PT131-30M-mA-0.5-M14-3M-K) | |||||||
| Model code | Measurement range | unit of measurement | output signal | Comprehensive accuracy | mechanical connection | Wiring length | with temperature |
| PTH503 | 30 | M | mA | 0.5 | M14 | 3M | K |
| Indicate with actual numbers | M=(MPa) | mA=(4-20mA) | 0.5=(0.5%FS) | M14=(M14X1.5) | 3M=(3 meters) | K=K-type thermocouple | |
| K=(KPa) | 10V=(0~10V) | Indicate with actual numbers | M22=(M22X1.5) | Indicate with actual length | J=K-type thermocouple | ||
| P=(Pa) | 5V=(0~5V) | M20=(M20X1.5) | E=E-type thermocouple | ||||
| B=(Bar) | mV=(2mV/mV) | G1/2=(G1/2) | No indication by default | ||||
| mH=(mH20) | G1/4=(G1/4) | ||||||
| mmH=(mmH20) | 1/2-20UNF | ||||||
| ZG1/4 | |||||||