Product Overview/Product overview----------------------------------------------------------◆◆
|
The intelligent digital display regulator is a high-performance, high reliability intelligent industrial measurement and control instrument that adopts a new design concept. Specially designed for connecting liquid level, pressure, temperature sensors and transmitters to form liquid level, temperature, and pressure measurement and control systems with various ranges and specifications. Widely used in industries such as chemical engineering, ceramics, metallurgy, petrochemicals, and heat treatment. |
Product selection/product selection-----------------------------------------------------------◆◆
|
Type spectrum |
Remarks |
Outline dimension code
Width * Height * Depth
|
A |
96×96×77 |
B |
48×96×77 |
C |
96×48×77 |
D |
160×80×77 |
E |
80×160×77 |
F |
72×72×74 |
G |
48×48×93 |
Main control output |
0 |
not have |
J5 |
Relay (250VAC/3A normally open) |
J6 |
Relay (250VAC/0.8A normally open) |
J8 |
Relay (250VAC/3A normally open+normally closed) |
J9 |
Relay (250VAC/0.8A normally open+normally closed) |
J7 |
Dual relay (250VAC/0.8A normally open) |
Auxiliary output 1 |
0 |
not have |
J8 |
Relay (250VAC/3A normally open+normally closed) |
J9 |
Relay (250VAC/0.8A normally open+normally closed) |
J7 |
Dual relay (250VAC/0.8A normally open) |
I5 |
Current transmission output |
U5 |
Voltage transmission output |
V6/V7 |
Feed 12V/24V |
Auxiliary output 2 |
0 |
not have |
J8 |
Relay (250VAC/3A normally open+normally closed) |
J9 |
Relay (250VAC/0.8A normally open+normally closed) |
I5 |
Current transmission output |
U5 |
Voltage transmission output |
S2 |
RS232 communication |
S4 |
RS485 communication |
V6/V7 |
Feed 12V/24V |
Auxiliary output 3 |
0 |
not have |
J8 |
Relay (250VAC/3A normally open+normally closed) |
J9 |
Relay (250VAC/0.8A normally open+normally closed) |
I5 |
Current transmission output |
U5 |
Voltage transmission output |
V6/V7 |
Feed 12V/24V |
|
Technical indicators/Technical indicators---------------------------------------------------------◆◆
|
Input specifications and range: |
Thermocouple: S(-50~1768)、R(-50~1768)、B(250~1820)、 K(-200~1372)、N(-200~1300)、E(-200~1000)、 J(-200~1200)、T(-200~400) |
Thermal resistance: PT100 (-200~800), Cu50 (-50~150), Cu100 (-50~150) |
Standard Millivolt Signal: Custom 0~100mV Standard Resistance Signal: Custom 0~500 ohms |
Standard voltage signal: 0~10V, 0~5V, 1~5V, custom 0~10V |
Standard current signal: 4~20mA, 0~10mA, custom 0~20mA |
Measurement accuracy: 0.2 level (± 0.2% FS ± 1 word) |
Cold end compensation: ± 1 ℃ |
Sampling resolution: 1 ℃ or 0.1 ℃ |
Sampling period: 0.5 seconds for detecting out of range faults and resistors, displaying Sb |
Output mode: Relay contact output 0~10mA current output (load capacity<1000 ohms) |
4-20mA current output (load capacity<500 ohms) |
Alarm function: 4 sets of alarm registers, freely corresponding to each output position |
4 alarm modes to choose from (single-sided hysteresis upper limit alarm, single-sided hysteresis lower limit alarm, double-sided hysteresis upper limit alarm, double-sided hysteresis lower limit alarm) |
Power supply voltage: 85~265VAC |
Whole machine power consumption: less than 4W |
Usage environment: Temperature -10~+60 ℃, humidity 0~80RH% |
|
Display explanation--------------------------------------------------------------◆◆
|
1. Single row digital display: directly displays instrument measurement values. |
2. Double row digital display: The upper row displays the measured values. The lower row displays the set value. In the measurement state, the lower display can be switched to the percentage of the measured value by pressing the key. |
3. Double row digital tube+single analog strip: The upper row displays the measured values. The lower row displays the percentage of set values or measured values, while a single analog bar indicates the percentage of measured values or simulated outputs. |
4. Single row digital tube+double row analog bar: The digital tube displays the measured value of the instrument, and pressing the plus key can display the percentage of the measured value or the percentage of the analog output. The left row of analog bars indicates the percentage of measured values; The analog bar on the right row indicates the percentage of the set value or the percentage of the analog output. |
5. Double row digital tube+double row analog strip: The explanation for double row digital tube is the same as above (display instruction 2), and the explanation for double row analog strip is the same as above (display instruction 4). |
6. Indicator light: A light or J1 light, which is the SP1 alarm indicator light. |
|
The E light or J2 light is the SP2 alarm indicator light. |
|
B light or J3 light is the SP3 alarm indicator light. |
|
The C light or J4 light is the SP4 alarm indicator light. |
|
The light or J5 light is the SP5 alarm indicator light. |
|
The light or J6 light is the SP6 alarm indicator light. |
|
Appearance and installation dimensions/Outline installation and size------------------------------------------◆◆
|
 |
|
Table 2 |
 |
|
Wiring Instructions/Wiring instructions------------------------------------------------------------◆◆ |
 |
 |
 |
|
Panel Description/Panel shows-------------------------------------------------------------------◆◆
|
 |
1. Display content status indicator light, HIS historical data browsing, LOG log browsing, PRG model not involved, AT model not involved |
2. 20 segment light column indicator, displaying the percentage of transmission output or measurement value |
3. Set button, enter parameter setting state, confirm parameter modification, etc |
4. Left shift key, data shift during parameter setting process |
5. Press the key to set the parameter values in the parameter settings |
6. Press the up button, set the parameter value in the parameter settings, and enter the historical data browsing |
7. Corresponding position of indicator light: |
① OUT indicator light corresponds to the main output position REL1 |
② AUX1 indicator light corresponds to auxiliary 1 output position REL2 |
③ AUX2 indicator light corresponds to auxiliary 2 output position REL3 |
④ AUX3 indicator light corresponds to auxiliary 3 output position REL4 |
⑤ AUX4 indicator light corresponds to auxiliary 1 output position REL5 |
8. The lower display window displays alarm 1, alarm value AL1, analog transmission output value, parameter value, etc |
9. The upper display window shows the measured value PV1 and parameter code |
|
Product packaging/Product packaging----------------------------------------------------------◆◆
|
 |
|