Measurement medium: Especially suitable for high temperature and high pressure steam and water, and can also be used for various gases and liquids
Measurement accuracy: ± 1%
Repeatability: ± 0.2%
Pressure measurement methods: corner joint pressure measurement, flange pressure measurement
Environmental temperature:- 40-85℃
Range ratio: 1:15
Process temperature:- 50℃~+650℃
Process pressure: 0-420 bar (0-42 MPa)
Process connection: DN50-DN500
Communication protocol: HART、Modbus
Protection level: IP67
Explosion proof grade: Exia Ⅱ CT1-6, Exd Ⅱ CT1-5
MG9400 nozzle flowmeter
MG9410 split nozzle flowmeter
MG9420 integrated nozzle flowmeter
When gas flows through a tapered nozzle, a pressure difference is formed between upstream and downstream, and the flow rate can be calculated.
● It can display cumulative flow rate, instantaneous flow rate, pressure, and temperature simultaneously.
In addition to online and dynamic full compensation functions,
● It has self diagnosis and self setting range.
● Resistant to high pressure and high temperature
● High stability
Widely used in process measurement in petroleum, chemical, metallurgical, power, light industry and other industries.