Our newly launched dissolved oxygen analyzer adopts advanced fluorescence testing technology, which has the advantages of low maintenance, easy calibration, fast and accurate testing.SD 400 Oxi LThe fluorescence method dissolved oxygen tester is equipped withFluorescent electrode, based on the principle of fluorescence measurement, does not consume oxygen and has stable measurement results at any flow rate. Easy to maintain.
2、 Performance characteristics
1、 Fluorescence based dissolved oxygen measurement technology does not require electrolytes.
2、 accuracy
3、 No lower limit flow rate requirement for samples
4、 Low maintenance volume
5、 No electrolyte replacement fee
6、 Long lifespan of fluorescent film
7、 Not affected by toxic media
8、 No drift, optical measurement
9、 Concise and intuitive operation
10, adaptable16.4mmofBODBottle testing
11Protection levelIP 67
12BacklightLCD
13Internal data storage
14Software used for monitoring and storing data
15、Micro USBport
16, MatchableBOD Karlsruhe NS 19 / 26 (16,4 mm ØAnd above)
3、 Technical parameters
1、 Probe: Fluorescence methodDO
2、 Protection level:IP 67(Sensor)
3、 Display:LCD
4、 Data storage:Micro SDblock
5、 Data logger: software used for monitoring and storing data
6、 Software: already included
7、 Connection port:Micro USB
8、 Automatic shutdown: No operation10Minutes later
9、 Power Supply:Micro USBperhaps4 x AAbattery
10Salinity:0…50pptAutomatic compensation (manually input salinity value)
11Response time: 40secondT90
12Storage temperature:-5℃-50℃
13Working temperature:-5℃-50℃
14Instrument size:162 x 98 x 54(L x W x H)
15Weight: Approximately314g(including battery)
16Language: Simplified Chinese
17Measurement range:
①Dissolved oxygen:0-50mg/l
②Saturation:0-500%
③Temperature:-5-50°C
④Air pressure:51-112kPa
18Resolution:
①Dissolved oxygen:0.01mg/l
②Saturation:0.1%
③Temperature:0.1°C
④Air pressure:0.1kPa
19Accuracy:
①Dissolved oxygen:0-200%perhaps0-20mg/l:±1.0%Reading or ±0.1 mg/l(Take the larger value)
>200%perhaps>20 mg/l:±10%test value
②Temperature:±0.2°C
③Air pressure:±0.2%
4、 Standard configuration
1、 SD 400 Oxi L,Set 1
①Order number:740000
②contain:1.5mCable probe,4(AA)Battery, storage calibration bottle, calibration dataMicro SD CardSoftware, user manual, quick use guide, portable case
2SD 400 Oxi L,Set 2
①Order number:740010
②contain:3mCable probe,4(AA)Battery, storage calibration bottle, calibration dataMicro SD CardSoftware, user manual, quick use guide, portable case
3SD 400 Oxi L,Set 3
①Order number:740020
②contain:10mCable probe,4(AA)Battery, storage calibration bottle, calibration dataMicro SD CardSoftware, user manual, quick use guide, portable case