Comparison Table of Model Parameters for Rail type DC Electric Meters |
||||||
LCDG- |
DZS1B |
DZS2B |
DZS3B |
DZS4B |
DZS5B |
DZS6B |
|
|
|
|
|
|
|
INPUT |
||||||
signal type |
direct-current |
|||||
Voltage level |
DC-48V, DC240V optional |
|||||
Direct current input |
75mv\20mA\±4V |
|||||
Current access type |
Hall sensor/splitter optional |
|||||
Number of signal input channels |
1 |
2 |
3 |
4 |
5 |
6 |
communication |
||||||
RS485 interface |
1 RS485 interface, half duplex, optoelectronic isolation, ± 15KV ESD protection, two-wire system |
|||||
Standard Communication Protocol Set |
MODBUS-RTU protocol, DL/T645-2007 protocol |
|||||
Serial port settings |
Baud rate: 1200-9600Can be set; Data bits 7-8; Stop position 1-2; Parity check can be set |
|||||
Device Address |
MODBUS address, 645 protocol address |
|||||
Set up tools |
tool software |
Dial switch/tool software |
tool software |
Dial switch or setting software for parameter settings |
||
Infrared Interface |
Not Supported |
support |
Not Supported |
support |
||
FUNCTION |
||||||
basic function |
Storage of voltage, current, power, forward and reverse electrical energy, and 1-4 types of load record data |
|||||
Historical data storage |
Support, 64KByte |
|||||
Parameter settings |
tool software |
Infrared/software/dip switch |
tool software |
Infrared, software, dip switch |
||
Extended functionality |
||||||
clock |
support |
|||||
appearance |
||||||
display screen |
LCD, 7-bit |
|||||
pilot lamp |
Operation and pulse indication |
|||||
External dimensions |
76*89*84 |
76*89*70 |
126*89*74 |
126*89*70 |
||
Performance and usage environment |
||||||
Electric energy accuracy |
Level 1 |
|||||
Input overload capacity |
1.2 times the range input can measure correctly;100ms3 times the voltage and 5 times the current range without damage; Voltage input impedance ≥ 100k Ω/V; Current ≤ 10M Ω |
|||||
Auxiliary power supply |
not have |
|||||
EMC Metrics |
Fast transient pulse>2KV |
|||||
IP protection |
IP51 |
|||||
quarantine |
Input and communication isolation voltage>1KV |
|||||
isolation |
Input, output, power supply and housing insulation>=5M Ω |
|||||
operation temperature |
-20℃~50℃ |
|||||
storage temperature |
-20℃~60℃ |
|||||
power consumption |
<1.5+(each channel * 0.5) W |
|||||
other |
||||||
Hall sensor power supply |
± 15V, the instrument provides power supply |
|||||
Standards |
||||||
safety standards |
GB4793.1-2007/IEC61010-1: 2001 Safety requirements for electrical equipment used in measurement control and experimentation |
|||||
EMC |
GB/T17626 Electromagnetic compatibility, measurement and experimental techniques |
Comparison Table of Model Parameters for Rail type DC Electric Meters |
||||||
LCDG- |
DZS1B |
DZS2B |
DZS3B |
DZS4B |
DZS5B |
DZS6B |
|
|
|
|
|
|
|
INPUT |
||||||
signal type |
direct-current |
|||||
Voltage level |
DC-48V, DC240V optional |
|||||
Direct current input |
75mv\20mA\±4V |
|||||
Current access type |
Hall sensor/splitter optional |
|||||
Number of signal input channels |
1 |
2 |
3 |
4 |
5 |
6 |
communication |
||||||
RS485 interface |
1 RS485 interface, half duplex, optoelectronic isolation, ± 15KV ESD protection, two-wire system |
|||||
Standard Communication Protocol Set |
MODBUS-RTU protocol, DL/T645-2007 protocol |
|||||
Serial port settings |
Baud rate: 1200-9600Can be set; Data bits 7-8; Stop position 1-2; Parity check can be set |
|||||
Device Address |
MODBUS address, 645 protocol address |
|||||
Set up tools |
tool software |
Dial switch/tool software |
tool software |
Dial switch or setting software for parameter settings |
||
Infrared Interface |
Not Supported |
support |
Not Supported |
support |
||
FUNCTION |
||||||
basic function |
Storage of voltage, current, power, forward and reverse electrical energy, and 1-4 types of load record data |
|||||
Historical data storage |
Support, 64KByte |
|||||
Parameter settings |
tool software |
Infrared/software/dip switch |
tool software |
Infrared, software, dip switch |
||
Extended functionality |
||||||
clock |
support |
|||||
appearance |
||||||
display screen |
LCD, 7-bit |
|||||
pilot lamp |
Operation and pulse indication |
|||||
External dimensions |
76*89*84 |
76*89*70 |
126*89*74 |
126*89*70 |
||
Performance and usage environment |
||||||
Electric energy accuracy |
Level 1 |
|||||
Input overload capacity |
1.2 times the range input can measure correctly;100ms3 times the voltage and 5 times the current range without damage; Voltage input impedance ≥ 100k Ω/V; Current ≤ 10M Ω |
|||||
Auxiliary power supply |
not have |
|||||
EMC Metrics |
Fast transient pulse>2KV |
|||||
IP protection |
IP51 |
|||||
quarantine |
Input and communication isolation voltage>1KV |
|||||
isolation |
Input, output, power supply and housing insulation>=5M Ω |
|||||
operation temperature |
-20℃~50℃ |
|||||
storage temperature |
-20℃~60℃ |
|||||
power consumption |
<1.5+(each channel * 0.5) W |
|||||
other |
||||||
Hall sensor power supply |
± 15V, the instrument provides power supply |
|||||
Standards |
||||||
safety standards |
GB4793.1-2007/IEC61010-1: 2001 Safety requirements for electrical equipment used in measurement control and experimentation |
|||||
EMC |
GB/T17626 Electromagnetic compatibility, measurement and experimental techniques |
Download attachment: