Intelligent high chlorine wastewater COD digestion instrument
Product Introduction: The intelligent high chlorine wastewater COD digestion instrument is a high chlorine wastewater COD digestion instrument that us
Product details

Product Introduction

Intelligent high chlorine wastewaterCODDigester

A high chlorine wastewater with proportional automatic adjustment system to control nitrogen flow rateCODDigester;

A product that fully complies with national standardsHJ/T 70-2001Determination of Chemical Oxygen Demand for High Chlorine Wastewater - Chlorine Calibration Method "Testing Standard for High Chlorine WastewaterCODDigester;

Instrument usage:

Used for high chlorine water bodies(Water and wastewater with chloride ion concentration greater than1000MG/L,less than20000MG/L)hit the targetCODSample dechlorination and digestion.

Applications:

High chlorine wastewater from oil fields, coastal refineries, oil depots, chlor alkali plants, steel mills, power plants, pesticides, food, textile printing and dyeing enterprises, as well as deep-sea discharge of wastewaterCODdetermination.

Product Features:

The heating unit adopts far-infrared ceramic heating technology that meets the export EU technical standards, with a stable and controllable heating rate;

Dissolving unit: 1-6position,Can be single hole single control;

The nitrogen flow rate control adopts an automatic proportional adjustment distribution system, with uniform flow distribution and stable flow rate, and the flow rate can be freely set

.The cooling system adopts a built-in compressor for cooling, and the cooling water automatically circulates internally without the need for external cooling water;

The host is equipped with a nitrogen automatic anti backflow unit, which can prevent the absorption liquid from being sucked back after heating is completed;

Touchable LCD, easy and fast to operate

The digestion time is controlled by a computer program and can be freely set. It can automatically stop when the digestion is completed;

Product specifications:

PRODUCT MODEL

GL-600

Anti oxidative interference

1000-20000MG/L

measuring range

10-700MG/LBeyond this limit, dilution is required for measurement

Nitrogen flow rate control

Parallel allocation with automatic flow control Can be controlled through a single channel

Nitrogen control range

0-100ML/MIN

Nitrogen control accuracy

2%

digestion time

0-999MINadjustable

temperature range

room temperature~400

End point control

Automatically stop heating when the set digestion time is reached, and switch the nitrogen flow rate automatically

Establish a static flow without the need for manual monitoring