1Equipment structure and working principle diagram
The main structure of the drying oven is shown in the attached figure: Front sectional view
2Overview of Working Principle
This drying oven is a drying equipment with circulating ventilation and automatic control of the entire process. The drying oven is equipped with a high-temperature resistant centrifugal blower,During work, the hot air (adjusted internally through the air supply duct) set in the heating chamber of the drying oven is uniformly forced into the working chamber through a blower,After exchanging heat with the workpiece in the studio, the hot air flows back to the return air duct and is then sent to the heating chamber for heating by the blower,Hot air repeats itself in the drying oven,Make the temperature inside the drying oven meet the process requirements.
This product has the characteristics of high temperature control accuracy, easy operation, energy saving, high safety and reliability.Widely used in the spraying industry for mold PTFE spraying, mold preheating, epoxy casting curing and drying processes.
|
rule grid
inside Rong |
Hot air circulation drying oven(High temperature drying oven) |
|
|
number quantity |
4 units (including 4 trolleys) |
|
|
An pretend use ruler inch |
||
|
studio dimensions |
1500×3000×1000mm(Width x Depth x Height) (Height refers to the height dimension of the studio) |
|
|
Overall dimensions |
2040*33001540mm(Width x Depth x Height), excluding external accessory dimensions |
|
|
Chassis load-bearing capacity |
Fixed with channel steel feet, I-shaped track at the bottom of the oven, No. 12 light rail, extended to 4.5 meters outside the box. |
|
|
material rack |
Configure a set of product racks, with the frame made of No. 8 channel steel and No. 5 channel steel laid in the middle, cross welded, and made of stainless steel. The wheels and transmission shaft of the small car are made of carbon steel, and the material of the 12th track at the bottom is carbon steel. The size of the car is 2900 * 1400mm, and the total height of the car is 250mm |
|
|
Lord want skill technique ginseng number |
||
|
On site environmental conditions |
Temperature:5-40℃ Relative humidity: not greater than85% Suitable for indoor use
There is no strong vibration or airflow around
No corrosive gases or chemicals present
Non drying flammable and explosive materials |
|
|
Equipment Composition |
Composed of furnace body, hot air circulation system, electric heating system, intake and exhaust system, circuit control system, etc |
|
|
electricity source |
3N+PE 380V 50Hz |
|
|
Temperature range for use |
Room temperature~500℃ (adjustable arbitrarily) |
|
|
warm-up time |
≤90Minutes, empty furnace test |
|
|
Temperature Uniformity |
≤±2.5%℃[national standard] |
|
|
temperature fluctuation |
≤±1℃;[national standard] |
|
|
heating power |
72kw |
|
|
insulation thickness |
150mmleft and right |
|
|
Surface temperature rise |
The national standard is room temperature+35℃ |
|
|
|
stove body be unify knot constitute |
|
|
structural form |
Adopting a monolithic structure.Concentrated placement |
|
|
Opening method |
Front facing door of furnace body.(The door lock adopts chrome plated sheep horn handle and steel hinge) |
|
|
Furnace shell |
Q235After rust prevention treatment, cold-rolled steel plates are sprayed with acrylic self drying paint |
|
|
Furnace inner liner |
stainless steel plate |
|
|
Shell skeleton |
Q235Rust removal and rust prevention treatment for channel steel and angle steel |
|
|
Inner liner skeleton |
Q235After rust removal and rust prevention treatment of angle steel, spray coatingW61Series of silicone heat-resistant paint |
|
|
bottom plate |
Q235After rust removal and rust prevention treatment of channel steel, spray coating851Moisture resistant coating. |
|
|
thermal insulation material |
Low thermal conductivity, high-quality high-temperature resistant aluminum silicate cotton |
|
|
sealing material |
High density ceramic fiber rope seal |
|
|
drum wind be unify |
||
|
Working Principle: |
The air is blown into the left and right air ducts by a high air volume blower, and after heat exchange with the electric heating elements in the ducts, it is blown out from the lower air outlet of the left and right air ducts. After entering the working room and exchanging heat with the workpiece, it returns to the blower motor through the top return air plate, thus forming a continuous hot air cycle. Simultaneously using a porous regulating plate for air volume adjustment ensures good temperature uniformity within the workspace. Vertical air supply from bottom to top |
|
|
air supply mode |
Studio hot air supply method: horizontal high-pressure air supply on both sides simultaneously |
|
|
Blower motor |
High temperature resistant long shaft motor specifically designed for curing furnaces, with a noise level of65dBthe following |
|
|
Blast power |
1.5KW4 units |
|
|
Installation position of motor |
Set at the top of the furnace body |
|
|
add hot be unify |
||
|
Heater position |
Inside the air ducts on both sides |
|
|
electric heater |
UThe font safe low load electric heating tube is of reliable quality, with 24 units of 3KW. |
|
|
enter\\\\exhaust system |
||
|
intake valve |
4 air intakes at the top fan base |
|
|
exhaust valve |
Two manual exhaust valves are installed in front of the top (adjustable in size according to the required exhaust volume). The supplier reserves flange interfaces,
External exhaust pipes are customized according to the actual situation in the workshop |
|
|
Automatic exhaust |
There is one exhaust device at the top, with a power of 180W, controlled by a switch, and the exhaust time is set by a time control device. |
|
|
electricity control be unify |
||
|
control manufacture cabinet |
Adopting an independent control cabinet for control, the surface of the control cabinet is treated with spraying and painting.
Two sets of temperature control systems before and after |
|
|
Lord control table |
Digital display intelligent instrument XGQ-A2100FAutomatic temperature control, constant temperature and beltPIDAdjust. Control accuracy ±1℃. |
|
|
electrical components |
Adopting domestic and foreign famous brands, such as Chint, Shanghai People, Omron, etc |
|
|
Over-temperature alarm
|
When the studio or heating room exceeds the temperature limit, it can automatically cut off the heating power and sound and light an alarm |
|
|
heating control |
Suzhou Integrated ElectronicsSSRSolid state relays have contactless power regulation and use input stages with optoelectronic isolation,
TTLLevel compatible input, DC or pulse triggered, with no contacts and no mechanical moving parts,
No sparks, no movement noise, vibration resistance, long lifespan and other characteristics. |
|
|
guarantee
protect
be
unify
match
place |
● Two sets of over temperature alarm systems When there is an abnormal change in temperature inside the furnace, an audible and visual alarm will be triggered, and
● Automatically cut off the heating power supply.
● Motor and heating interlock control Start with the blower before heating to prevent the heater from burning out and causing accidents.
● Motor overload protection Prevent the motor from burning out and tripping.
● Short circuit protection for electric heaters Prevent electric heaters from short circuiting and burning out
● Control circuit protection Prevent short circuits in the circuit and prevent accidents
● circuit breaker Prevent overload and short circuit of the main circuit, which may cause accidents
● Power prevention after power outage Prevent damage to baked goods caused by increased baking time after power on |
|
|
solid transform stove Appendix document and its it say bright |
||
|
Yan color |
Computer gray white |
|
|
random file |
Instruction Manual1copy/Taiwan