HI2300 Total Solid Solubility Tester/HI2300 Desktop Dissolved Oxygen Analyzer

HI2300EC/TDS/NaCl/℃ multifunctional portable conductivity meter

HI2300
The measuring instrument host HI76310 has ATC four ring conductive electrode related accessories
12500.00
Market price
HI2300P
The measuring instrument host HI76310 is equipped with ATC four ring conductive electrode carrying box related accessories
12700.00
Market price

Parameters of HI2300 Total Solid Solubility Tester

HI2300 is a microcomputer controlled, conductivity/total solid solubility/sodium chloride desktop measuring instrument.HI2300 Total Solid Solubility TesterIts unique automatic range selection function can automatically identify and select the range based on the measured sample, without the need to replace the probe.HI2300 Total Solid Solubility TesterTemperature compensation can be done manually or automatically, and users can choose the temperature coefficient value independently. This function can also be turned off for actual conductivity measurement. The instrument also has a stability indicator to remind users when to record measurement results.HI2300 Total Solid Solubility TesterIt also contains GLP performance, and the stored data can be input into the computer through the RS232 interface. In addition, users need to enter a unique ID number to identify the instrument.

Measurement indicators
Conductivity (EC)
Total Solid Solubility (TDS)
measuring range
(20 ℃ or 25 ℃)
Temperature compensation)
0.00 to 29.99μS/cm
(30.0 to 299.9μS/cm)
300 to 2999μS/cm
(3.00 to 29.99mS/cm)
30.0 to 200.0mS/cm
Up to 500.0mS/cm
(Measure conductivity value without temperature compensation)
0.00 to 14.99ppm
(15.0 to 149.9ppm)
150 to 1499ppm
(1.50 to 14.99g/l)
15.0 to 100.0g/l
Up to 400.0g/l
(Measure TDS value without temperature compensation)
Resolution
0.01μS/cm(0.00 to 29.99μS/cm)
0.1μS/cm(30.0 to 299.9μS/cm)
1μS/cm(300 to 2999μS/cm)
0.01ms /cm(3.00 to 29.99ms/cm)
0.1mS/cm (above 30.0mS/cm)
0.01ppm(0.00 to 14.99ppm)
0.1ppm(15.0 to 149.9ppm)
1ppm(150 to 1499ppm)
0.01g/l(1.50 to 14.99g/l)
0.1g/l (above 15.0g/l)
accuracy
± 1% reading ± (0.05 μ S/cm measurement value)
± 1% reading ± (0.03ppm measurement value)
Correction point
Equipped with six calibration points for automatic recognition
Conductivity correction and TDS automatic recognition correction simultaneously
Conversion factor
__
0.40 to 0.80 (factory default value of 0.50)
temperature compensation
Automatic or manual compensation from 0 to 60 ℃
Automatic or manual compensation from 0 to 60 ℃
Temperature compensation constant
0.00 to 6.00%/℃ (factory default value 1.90%/℃)
Measurement indicators
Salinity (NaCl)
Temperature (℃)
measuring range
0.0 to 400.0%
0.0 to 60℃
Resolution
0.10%
0.1℃
Accuracy
± 1% reading
±0.4℃
Correction point
Single point automatic recognition calibration (recommended calibration solution HI7037)
2 temperature calibration points at 0 ℃ and 50 ℃
(Adjust interval ± 1 ℃)
Supporting electrode
HI76310 has ATC function, four ring high-performance conductive electrode (conductivity constant K=1)
data interface
RS232
Supporting power supply

HI710006 dedicated 220V/12VDC power supply

application environment
0.0 to 50.0 ℃ 95% RH
Size/Weight
240×182×74mm / 1200g