Beijing Huayi Tongtai Technology Co., Ltd. specializes in the sales of imported analytical and testing instruments. We provide a wide range of products, competitive prices, and excellent after-sales service.
GermanywtwinoLab Cond 7110/7310Conductivity testerEasy to operate and convenient to use;GermanywtwinoLab Cond 7110/7310Conductivity testerAutomatic reading function ensures repeatable results
GermanywtwinoLab Cond 7110/7310Conductivity testerProduct Introduction:
In general laboratory use, inoLab 7110Series beauty is suitable for routine measurements. Regardless of measurementpHThis series offers advanced features that are easy to use, including environmental conductivity, medical, chemical, pharmaceutical, and food and beverage industries. The direct user interface, easy to clean exterior design, and keyboard make these instruments ideal for all environmental measurements.
Precision measurement
Automatic reading(AutoRead)The function provides repeatable measurement results. The instrument can recognize when a stable measurement value can be reached. The calibration timer reminds users to periodically calibrate to ensure accuracy.
Easy to operate
The keyboard design provides intuitive operation, and the large and clear display screen allows you to see all the necessary information at a glance.
All instruments can be selected from various application packages, including sensor electronics and AC power supply.
with inoLab 7310 series.
●Fast data transmissionUSBinterface
●completelyCSVFormat data transmission
●Optional built-in printer for data output
GermanyWTWinoLab Cond 7110/7310Conductivity TestInstrument features:
Precision measurement
with inoLab 7110 series.
●Automatic reading function ensures repeatable results
●Easy to calibrate, with built-in calibration timing
●Intuitive user interface
Precision measurement+document
7310The series providespHMeasurement of conductivity and dissolved oxygen. Suitable for requesting supportAQAandGLPAll laboratory applications of documents. These instruments provide7110In addition to all the essential features of the series, some additional functions have been added.
easy operation
The display interface provides convenient and secure operation. All necessary information is displayed on a bright and clear screen, which can be seen at a glance.
Complete Record
In order to facilitate the transmission of general or stored data,inoLab 7310Series useUSBInterface andPCconnect. A built-in data logger with adjustable storage intervals provides automatic recording of all measurement data. Date, time, andIDThe number meets the requirements of providing good laboratory practices. Users can also input the sensor serial number to request the complete document. All data can be easily processedCSVFormat transmission;WTWProvided an additionalexcelRecords used for measurement design and calibration.
InoLab 7310PProvides a built-in printer for directly printing measurement and calibration results.
inoLab Cond 7110/7310Conductivity tester
Conductivity measurement
newCMCThe function can monitor the calibration range and display whether the measurement range is between the calibration points. Effective data results can display any small deviations to ensure high accuracyPHMeasurement value.
All instruments can be selected from various application packages, including sensor electronics and AC power supply.
GermanywtwinoLab Cond 7110/7310Conductivity testerTechnical parameters:
instrument |
inoLab Cond 7110 |
inoLab Cond 7310 |
|
All values +/-1 digit |
All values +/-1 digit |
conductivity |
0 uS/cm ~ 1000 mS/cm +/- 0.5 %Measurement value |
0 uS/cm ~1000 mS/cm +/- 0.5 %Measurement value |
resistivity |
- |
0.00 ~ 20 MOhm cm |
Electric constant |
0.450 ~ 0.500 cm-1, 0.800 ~0.880 cm-1,fixed0.01 cm-1, |
0.450 ~ 0.500 cm-1, 0.800 ~ 0.880 cm-1, |
salinity |
0.0 ~ 70.0 (acc. IOT) |
0.0 ~ 70.0 (acc. IOT) |
TDS |
0 ~ 1999 mg/l |
0 ~ 1999 mg/l, 0 ~ 199.9 g/l |
celsius/Fahrenheit |
correct |
correct |
temperature |
-5.0 ~ 105.0 °C +/- 0,1 °C |
-5.0 ~ 105.0 °C +/- 0,1 °C |
Auto Read |
automatic |
automatic/hand movement |
Sensor plug |
8 pin |
8 pin |
calibration |
1drop |
1drop |
reference temperature |
20 °C/25 °C |
20 °C/25 °C |
temperature compensation |
NonenLFNonlinear, linear0.000 ~ 3.000%/K |
NonenLFNonlinear, linear0.000 ~ 10.00 %/K |
Calibration capacity |
Current calibration record |
quite a lot10A correction record |
display |
7paragraphLCD |
BacklightLCD |
storage |
|
500Group Manual/5000Group Automatic |
Recorder |
- |
hand movement/time control |
interface |
- |
miniUSB |
printer(optional) |
- |
Hot printing,width58 mm |
power supply |
universal power supply, 4x1,5VAAperhaps4 x 1,2Vrechargeable battery |
universal power supply, 4x1,5 V AAperhaps4 x 1,2 Vrechargeable battery |
Standard configuration |
|
1CA100 |
inoLab ® Cond 7110 Laboratory Conductivity Tester, Main Unit Only, Including Battery, Power Adapter, Bracket, and Operating Manual |
1CA101 |
inoLab ® Cond 7110 SET 1 laboratory conductivity tester, mainframe, including power adapter, bracket, TetraCon ® 325 conductivity meter, 0.01mol/l KCL conductivity standard solution |
1CA103 |
inoLab ® Cond 7110 SET 3 laboratory conductivity tester, mainframe, including power adapter, bracket, KLE 325 conductivity meter, 0.01mol/l KCL conductivity standard solution |
optional accessories |
|
consult |
Various conductivity indicators, calibration solutions, etc. |
Standard configuration |
|
1CA300 |
inoLab ® Cond 7310 Laboratory Precision Conductivity Tester, Main Unit Only, Including Power Adapter, Bracket and Operating Manual, Software and USB Cable |
1CA300P |
inoLab ® Cond 7310P laboratory precision conductivity tester, only for the host, with a built-in thermal printer, power adapter, bracket and operation manual, software and USB cable |
1CA301 |
inoLab ® Cond 7310 SET 1 laboratory conductivity tester, mainframe, including power adapter, bracket, TetraCon ® 325 conductivity meter, 0.01mol/l KCL conductivity standard solution, software and USB cable |
1CA306 |
inoLab ® Cond 7310 SET 6 laboratory conductivity tester, mainframe, including power adapter, bracket, LR 325/01 pure water conductivity meter, D 01/T flow cell, 5 μ s/cm calibration solution, software and USB cable |