German WTW Cond 7300 laboratory desktop conductivity/resistivity/TDS/salinity tester Product introduction:
Large size multifunctional LCD display, a good choice for routine laboratory analysis; Can test conductivity/temperature/salinity/TDS, matched with TetraCon's proprietary 4 very conductive and pollution resistant, can provide very accurate test results. Simple and economical inoLab Cond 720 exquisite and practical inoLab Cond 730 standard configuration host, multifunctional box, electrical cabinet, KCL solution, beaker, power transformer, operation manual, compact and lightweight structure; Easy to operate; It can be placed on the desktop or wall mounted
The main features of the German WTW Cond 7300 laboratory desktop conductivity/resistivity/TDS/salinity tester are:
Specific application display
Touch sensitive buttons with touch points and tactile response
Battery or AC adapter power supply working
Simple operation and reliable results
Compact structure with high precision
Automatic temperature compensation
Multi point calibration
Technical parameters of the German WTW Cond 7300 laboratory desktop conductivity/resistivity/TDS/salinity tester:
German WTW inoLab @ Cond 7300 laboratory conductivity/resistivity/salinity/TDS/temperature measuring instrument
The important parameters for water quality monitoring in conductivity laboratory. This parameter is becoming increasingly important in the pharmacopoeia introduction of pharmaceutical water. WTW's inoLab @ Cond laboratory instruments meet all laboratory measurement requirements standards.
ambient temperature |
Storage temperature |
- 25 ℃~+ 65 ℃ |
|
operation temperature |
0℃~+ 55 ℃ |
[us/cm] |
0.000~1.999; 0.00~19.99; 0.0~199.9; 0~1999 |
|
[ms/cm] |
0.00~19.99; 0.0~199.9; 0~1999 |
|
Electrical resistivity [Mohm * cm] |
0.000~1.999; 0.00~19.99; 0.0~199.9; 0~1999 |
|
SAL |
0.0~70.0, refer to IOT table |
|
TDS[mg/L] |
0-1999, set factor 0.40-1.00 |
|
T[℃] |
-5.0~+105.0 |
|
T[°F] |
+23.0~+221.0 |
|
Accuracy (± 1 bit) |
±0.5% |
|
|
SAL |
±0.1 |
|
TDS[mg/L] |
1 |
|
T[℃] |
NTC 30 :±0.1 |
Conductivity constant (for setting) |
0.010; 0.090~0.110; 0.250~2.500 |
|
Conductivity constant (for calibration) |
0.450~0.500; 0.800~1.200 |
|
Size and weight (L × W × H) |
230mm × 300mm × 70mm, 1.3Kg (excluding power adapter) |
|
Data serial port |
RS 232, cable length of 15 meters |
|
power supply |
Battery: 4 1.5V AA alkaline manganese batteries, 3000Hrs |
|
|
ac adapter Input: 100-240VAC, 50-60Hz, 400mA Output: 9VDC, 1. a |