Shenzhen Kerei Technology Development Co., Ltd
Home>Products>GMS980 high-precision Gaussian meter calibration system
GMS980 high-precision Gaussian meter calibration system
Description: High precision Gaussian meter, with a maximum accuracy of 5ppm High performance, high-precision, high-power DC power supply, stability: 1
Product details

Provide professional magnetic field measurement solutions

Strong magnetic field measuring instrument(0 - 20T)

model

principle

type

number of axles

DCaccuracy

maximum range

Highest resolution

X113

hall

hall sensor

1

<>

15T

TC: 30ppm/K

G80

hall

handheld

1

2%

2T

10μT

G81

hall

handheld

1

0.8%

10T

1μT

G82

hall

handheld-high frequency

1

0.8%

10T

1μT

G83

hall

handheld

3

0.8%

10T

1μT

G92

hall

handheld

1

1%

10T

10μT

G93

hall

handheld

3

1%, 0.5%

20T

1μT

G201

hall

Desktop computer

1

0.2%

10T

1μT

G203

hall/reluctance

Desktop computer

3

0.2%

10T

10nT

G401

hall

Desktop computer

1

0.04%

10T

1μT

G403

hall

Desktop computer

3

0.04%

10T

1μT

GSP301A

hall

Analog transmitter

1

1%, 0.2%

10T

Output: ±3V

GSP301D

hall

Digital transmitter

1

1%, 0.2%

10T

1μT

GSP303D

hall

Digital transmitter

3

1%, 0.2%

20T

1μT

GSP303D-S

hall

Digital transmitter

3

0.5%, 0.1%

3T

1μT

Magnetic field testing system

GAS3000

Array magnetic field detection system, synchronous detection up to128The magnetic field at a certain location

GMS980

High precision Gaussian meter calibration system (High precision Tesla meter calibration device)

Weak magnetic field measuring instrument(0- 2mT)

Weak magnetic field Gaussian meter

model

principle

type

number of axles

DCaccuracy

maximum range

Highest resolution

GMR61

reluctance

handheld

1

0.8%

600μT

10nT

GMR63

reluctance

handheld

3

0.8%

600μT

10nT

GF601

fluxgate

handheld

1

0.5%

1mT

0.1nT

GF603

fluxgate

handheld

3

0.25%

1mT

0.1nT

GF633

fluxgate

Desktop computer

3

0.1%

100μT

0.01nT

GFP703

fluxgate

Smart Transmitters

3

0.5%

1mT

0.1nT

GFP703S

fluxgate

Spectrum analyzer

3

0.5%

1mT

0.01nT

GFP803

fluxgate

Smart Transmitters

3

0.2%

1mT

0.1nT

Communication magnetic field measurement(DC- 1MHz)

model

principle

type

number of axles

ACaccuracy

maximum range

frequency response

AMS-2K

alternating current coil

Analog sensor

1

1%

3mT

30Hz- 2kHz

AMS-1M

alternating current coil

Analog sensor

1

1%

3mT

2kHz- 1MHz

G1000

reluctance

Smart Transmitters

3

DC- 1% AC- 2%

400μT/ Axis

DC- 1MHz

GA1000

reluctance

handheld

3

2%

400μT/ Axis

30Hz- 1MHz

GSP301HFA

reluctance

Analog transmitter

1

1%

150μT

20Hz-1.2MHz

GSP303HFA

reluctance

Analog transmitter

1

1%

150μT

20Hz-1.2MHz

fluxgate sensor

model

principle

type

number of axles

noise level

maximum range

output

F901

fluxgate

Economic type

3

10 to 20pT

1000μT

±10V,single-ended

F902

fluxgate

low noise

3

<>

100μT

±10V,single-ended

F903

fluxgate

low-power consumption

3

10 to 20pT

200μT

±3V,finite difference

F904

fluxgate

low-power consumption|low noise

3

<>

100μT

±3V,finite difference

F905

fluxgate

high-performance|low noise

3

<>

100μT

±10V,single-ended

F906

fluxgate

low-power consumption

3

10 to 20pT

100μT

±3V,finite difference

F23

fluxgate

split type|large range

3

<>

1500μT

±10V,single-ended

F53

fluxgate

High temperature type

3

≤ 300pT@175

100μT

±5V,finite difference

Magnetic flux gate sensor data acquisition unit

FDU301

Connectable1A three-axis flux gate sensor

ASA1000

Connectable2-126A single axis flux gate sensor or2-42A three-axis flux gate sensor

AFS

Array flux gate sensor detection system, capable of connecting multiple flux gate magnetic field transmitters

GMR-16

Micro weak magnetic field sensor array, capable of synchronous acquisition2-16Data from a miniature weak magnetic field sensor

GR100

Digital three-axis flux gate gradiometer

remarks:

1Magnetic field unit conversion:1T= 10kG; 1mT= 10G; 1μT= 10mG; 1nT= 10μG

2Click on the left side of the table abovemodelYou can refer to the product information of the corresponding model


Tags: Gauss Meter Calibration Tesla Meter Calibration Standards Gauss Meter Magnetic Field Calibration System Gauss Meter Calibration

GMS980 high-precision Gaussian meter calibration system

(GMS980High precision Tesla meter calibration device)


sketch:

The GMS980 high-precision Gaussian meter calibration system is a high-precision, powerful, and intelligent Gaussian meter calibration system. This system adopts our company's high-precision fully digital Gaussian meter, high-performance, high-precision, high-power DC power supply, and high uniformity electromagnet to form a high-precision, high stability magnetic field generation platform with closed-loop control. Through software and hardware platforms, intelligent real-time display of preset values and magnetic field fluctuation graphics and values. The precision of the magnetic field generation platform is as high as ± 0.001% of the reading; Magnetic field generation degree: up to 2.4T; Magnetic field stability: 10ppm/8 hours. This system fully complies with the magnetic field calibration standard "JJG242-1995 Tesla Meter Calibration Regulations" of the Chinese Academy of Metrology, and is suitable for calibration by various metrology departments, as well as various magnetic research in scientific research institutions and military enterprises.

The GMS980 high-precision Gaussian meter calibration system has an accuracy of up to 5ppm and can calibrate Gaussian meters with an accuracy exceeding 0.01%.




Soft and Hard Platforms

1. High precision Gaussian meter, highest accuracy5ppm

2. High performance, high-precision, high-power DC power supply, stability:10ppm / 8Hour;

3. High uniformity electromagnet:Uniformity can reach10ppm /cm³;

4. Various supporting software and high-precision adjustment brackets and other accessories.




Detailed description of system composition

1. High-precision Gaussian meter

There are three types of high-precision Gaussian meters:G401The accuracy is0.04%)TheG501The accuracy is0.01%)And nuclear magnetic resonance Gaussian meterPT2025(accuracy5ppm)PT2026(accuracy5ppm)It is mainly used in measurement departments, scientific research institutions, military industry, shipyards and other large manufacturers.

Gauss meter

G401

G501

range

50KG(5T)

30KG(3T)

Highest resolution

0.1mG(10nT)

1mG(0.1μT)

Basic DC accuracy

±0.04%

±0.01%

Frequency range

DC- 30kHz

DC- 20kHz

temperature coefficient

<±50ppm>±50ppm>

<±50ppm>±50ppm>

communication interface

USB

USB

Display digits

complete6Position display

complete6Position display

Display

7Inch color resistive touch screen

7Inch color resistive touch screen

Display units

Gaussian(G)Tesla(T)Ampere per meter(A/m)

Gaussian(G)Tesla(T)Ampere per meter(A/m)



NMR Gauss meter

PT2025

PT2026

range

0.043T to 13.7T

0.038T to 22.8T

resolution

0.1μTperhaps1Hz

±0.1Hz

accuracy

±5ppm

±5ppmNot affected by temperature

Frequency range

1.9MHz- 90MHz

1MHz- 1GHz

communication interface

RS-232-CandIEEE-488 GPIB

USB/USBTMC, Ethernet / VXI-11

IEE488.2; SCPI

power supply

110/220V 50/60Hz, 40VA

90-255VAC 50/60Hz, 50W

Display units

TorMHz

TorMHz



2. Model 9100High performance, high-precision, high-power DC power supply





9100The high-performance, high-precision, and high-power DC power supply is a device that utilizes current/High precision and high-power DC power supply controlled by voltage, with current stability of up to10ppm/8Hours, high cost-effectiveness, excellent performance. Power up to12KW, with high efficiency93%, lightweight only32KGSuitable for power supply scenarios with high current, small size, and low cost.


Compared with traditional hard switch technology,
9100The high-precision and high-power DC power supply has excellent designs such as high-efficiency bridge rectification, phase modulation, and zero voltage switching power supply. The whole machine is designed and manufactured in Europe.



Electromagnetic power supply

9100

drift(8Within hours)

±10ppm

Line adjustment

±10% slow, T > 1 min

±5ppm

±1% fast, T > 3 m sec.

±5ppm

Load regulation(± 10%resistance variation)

±5ppm

Output ripple and noise(voltagepeak-to-peak)

< 100mv='' @='' 0-100=''>

temperature coefficient

ambient temperature15 – 40° C

5ppm/°C

ambient temperature15 – 30° C

1ppm/°C

Current setting resolution

20 bit DAC

Current stability accuracy

± 10ppm

Absolute calibration current

-0 / +400ppm

Current readback resolution

16 bit ADC

Voltage readback resolution

16 bit ADC

Current control range(Range setting)

1 - 100%

Uniform speed(0 – 100%)

0.1 - 10 sec (adjustable)

Current loop bandwidth

2 - 100 Hz

Voltage loop bandwidth

>200 Hz

Isolation test voltage (output as an example)

1 kV

Warm-up time(Cooling and standby)

30minute;15minute

ACpower input

360440VAC (400V ± 10%),Three phase four wire system,4763Hz

ACPower input efficiency

AC input voltage90%93%unequal

DCPower Output

voltage60V, optional current50A - 100 A - 150 A - 200 A



model selection

Unipolar, 380VACThree phase four wire input,water-cooling

9100-50A-U

50A/60VUnipolar, including: local control panel,RS232Communication interface, water-cooled

9100-100A-U

100A/60VUnipolar, including: local control panel,RS232Communication interface, water-cooled

9100-150A-U

150A/60VUnipolar, including: local control panel,RS232Communication interface, water-cooled

9100-200A-U

200A/60VUnipolar, including: local control panel,RS232Communication interface, water-cooled

Bipolar, 380VACThree phase four wire input,water-cooling

9100-50A-B

±50A/±60VBipolar, including: local control panel,RS232Communication interface, water-cooled

9100-100A-B

±100A/±60VBipolar, including: local control panel,RS232Communication interface, water-cooled

9100-150A-B

±150A/±60VBipolar, including: local control panel,RS232Communication interface, water-cooled



3. High uniformity electromagnet

SBThe Type Electromagnetic Magnet is a new generation of double yoke and double adjustable structure electromagnetic magnet from Koehler Technology GmbH in Germany.SBType electromagnet, its magnetic field air gap is adjustable in both directions, the double yoke structure forms a closed magnetic circuit, has good rigidity, and the magnetic field direction is horizontal; Yoke inclined type45The angled seat is convenient for taking and placing samples, as well as for combining with other equipment.

SBThe design of the electromagnetic coil with a reasonable magnetic circuit and pole size100mm—250mm, weight from200KG—1920KGTo form a series of products. The electromagnetic coil is finely processed to ensure the coaxial alignment of the pole and the maximum number of ampere turns of the wire package. It can be condensed to the smallest volume, and can obtain the strongest magnetic field per unit volume of the wire package for every kilowatt of excitation power. It can also ensure a large smoothness around the working air gap. The electromagnet can be naturally cooled or internally cooled with water cooling to ensure that it can be used at normal temperature.SBThe electromagnetic coil has a wide range of air gap adjustment, easy replacement of pole heads, and is suitable for various magnetic measurements.




electromagnet

SB-100

SB-130

SB-175

SB-200

SB-250

Maximum magnetic pole diameter(mm)

100

130

175

200

250

Adjustable range of air gap(mm)

0-120

Magnetic field(T

>2.0T

>2.0T

>2.0T

>2.0T

>2.0T

power(KW)

2.0

3.8

6.5

10.0

12.0

weight(KG)

200

430

630

930

1920


magnetic field homogeneityDetermined by the following factors: electromagnetic power, magnetic pole diameter, and air gap. By selecting suitable parameters, the magnetic field uniformity can reach one hundred thousandth/Cubic centimeters.




4Various supporting software and high-precision adjustment brackets and other accessories

4.1 Supporting software (upper computer software)

The software can set the DC power supply current value and generate a controlled electromagnetic uniform zone magnetic field by controlling the DC power supply current output; The software can set the target magnetic field value, achieve the target value after the system works, and automatically input it into the test table. The measured data needs to be manually input. After the tester completes the test from low field to high field, the software automatically generates a measurement table and measurement results. The testing standards are formulated according to the standards of the Chinese Academy of Metrology. Test data and tables can be stored in the database for archiving. Support printing test results.

4.2 Adjustment bracket (displacement platform)

The displacement platform is made of non-magnetic materials. Users can manually do itX,Y,ZMovement in direction,Move the probe steadily to a certain position and fix it. The positioning accuracy is0.1Millimeters. Through the displacement platform, the probe can be accurately positioned in the uniform magnetic field area, eliminating the influence of position and angle.

4.3 Water circulation cooling box: matched with the selected DC power supply.



Attachment:High precision magnetic field calibration system

System type

Magnetic field calibration range

Main parameters and configuration

DC magnetic field calibration system

high range

Range:10G - 20KG

Equipment composition:175mmElectromagnetic coil, nuclear magnetic resonance(NMR)Gaussian meter,10ppmHigh precision Degree power supply degree power supply

Accuracy:50ppm

Medium range

Range:1G-1000G

Equipment composition: high-precision solenoid,6 A half multimeter,10ppmHigh precision power supply,Standard Gaussian meter

Accuracy:0.01%

low range

Range:1μG – 1G

Equipment composition: large shielding bucket, three-dimensional Holmz coil,1μAHigh resolution and high-precision electrical Source, standard flux gate Gaussian meter

Accuracy:0.1%

Communication magnetic field calibration system

high range

Range:1G – 2000G

Frequency:10Hz-3KHz

Equipment composition:150ACommunication coil,6 Half multimeter, high-precision and high-power3KHzAC power supply, standard AC Gauss meter

Accuracy:0.1%

Medium range

Range:0.1G – 150G

Frequency:10Hz-30KHz

Equipment composition:20ACommunication coil,6 Half multimeter with high precision30kHzalternating current Source, standard communication Gaussian meter

Accuracy:0.1%

low range

Range:1mG - 1G

Frequency:10Hz-30KHz

Equipment composition: Holmz coil,6 Half multimeter with high precision30kHzalternating current Source, standard AC flux gate Gaussian meter

Accuracy:0.1%



Attached are other magnetic measurement product parameters

Provide professional magnetic field measurement solutions

Strong magnetic field measuring instrument(0 - 30T)

model

principle

type

number of axles

DC accuracy

maximum range

Highest resolution

G91

hall

handheld

1

2%

3T

10μT

G92

hall

handheld

1

1%

10T

10μT

G93
(Equipped with a strong magnetic field probe)

hall

handheld

3

1%

30T

1μT

G201

hall

Desktop computer

1

0.2%

5T

10nT

G401

hall

Desktop computer

1

0.04%

5T

10nT

G403

hall

Desktop computer

3

0.1%

3T

1μT

GSP301A

hall

Analog transmitter

1

1%, 0.2%, 0.04%

10T

Output±10V

GSP301D

hall

Digital transmitter

1

1%, 0.2%, 0.04%

10T

1μT

GSP303A

hall

Analog transmitter

3

1%, 0.5%, 0.25%, 0.1%

2T

Output±10V

GSP303D

hall

Digital transmitter

3

1%, 0.5%,0.1%

2T

1μT

Weak magnetic field measuring instrument(0- 1mT)

Weak magnetic field Gaussian meter

model

principle

type

number of axles

DC accuracy

maximum range

resolution

GMR50

reluctance

handheld

1

1%

1mT

10nT

G93
(Equipped with low field probe)

reluctance

handheld

3

1%

1mT

10nT

GF603

fluxgate

handheld

3

0.5%

1mT

0.1nT

GF633

fluxgate

Desktop computer

3

0.1%

100μT

0.01nT

GFP703

fluxgate

Smart Transmitters

3

0.5%

1mT

0.1nT

fluxgate sensor

model

principle

type

number of axles

Linearity

output

maximum range

noise level

F901

fluxgate

Economic type

3

<>

±10V,single-ended

1000μT

10 to 20pT

F902

fluxgate

low noise

3

<>

±10V,single-ended

100μT

<>

F903

fluxgate

low-power consumption

3

<>

±3V,finite difference

200μT

10 to 20pT

F904

fluxgate

low-power consumption&noise

3

<>

±3V,finite difference

100μT

<>

F53

fluxgate

High temperature type

3

<>

±10V,finite difference

100μT

300pT@175

Communication magnetic field measurement(30Hz- 1MHz)

model

principle

type

number of axles

AC accuracy

maximum range

frequency response

GA500

alternating current coil

handheld

1

1%

3mT

30Hz- 1MHz

GA1000

reluctance

handheld

3

2%

400μT/ Axis

30Hz- 1MHz

Magnetic field testing system

GAS3000

Array magnetic field detection system(Multi point synchronous testing system for magnetic field)

According to the configuration, the system can monitor simultaneously2~128The magnetic field of the road

Magnetic field calibration system

DC magnetic field
(High precision50ppm)

ac magnetic field
(High precision0.1%)

·Low range:0.1nT- 0.1mT
·
Medium range:0.1- 100mT
·
High range:1mT- 2T

·Low range:0.1μT- 0.1mT
·
Medium range:0.01- 15mT
·
High range:0.1- 200mT

remarks:1T= 10KG; 1mT= 10G; 1μT= 10mG; 1nT= 10μG






Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!