Fluke1550C/KIT digital insulation resistance tester
Fluke1550C/Fluke1550C/KIT digital insulation resistance tester Z has a high test voltage of 5KV and can be used for a wide range of high-voltage equip
Product details

Fluke1550C/Fluke1550C/KIT digital insulation resistance testerThe maximum test voltage is 5KV, which can be applied to a wide range of high-voltage equipment, including switchgear, motors, generators, and cables. Fluke's insulation tester can now perform the entire range of test voltages specified in IEEE 43-2000 and *, with a 3-year warranty and CAT IV 600 V safety level. With measurement storage and PC interface, Fluke1555 and Fluke1550 are tools designed to identify preventive or predictive maintenance plans for potential equipment failures before they occur.

Fluke1550C/Fluke1550C/KIT digital insulation resistance testerFeatures and advantages:

  • Fluke1550Czui high test voltage of 5 kV, suitable for all applications
  • CAT III 1000 V, CAT IV 600 V safety level
  • The voltage breakdown detection function can remind users of the existence of voltage and provide the highest voltage reading of 600 V (AC or DC), improving user safety
  • Within the range of 250-1000 V, the test voltage can be selected in steps of 50 V; When the voltage is higher than 1000 V, the test voltage can be selected in 100 V steps
  • Measurement values can be stored in up to 99 storage locations, with each location assigned a user-defined label * for easy access
  • Long battery life, capable of conducting over 750 tests between two charges
  • Automatically calculate the medium absorption ratio (DAR) and polarization index (PI) without the need for additional settings
  • The protection system can eliminate the influence of surface leakage current during high resistance measurement
  • Large digital/analog LCD display screen for easy viewing
  • Capable of measuring capacitance and leakage current
  • Equipped with a ramp function for breakdown testing
  • Measurable up to 2TThe resistance
  • During scheduled testing, a timer setting of up to 99 minutes can be performed
  • 3-year warranty

Fluke1550C Insulation Resistance Tester Kit Accessories Diagram

Fluke1550C/Technical parameters:

Insulation resistance measurement

Test voltage (DC)

Range (DC)

Accuracy (± reading)

250 V < 200 kΩ
200 k Ω to 5 G Ω
5 G Ω to 50 G Ω
> 50 GΩ
not specified
5 %
20 %
not specified
500 V 200 kΩ
200 k Ω to 10 G Ω
10 G Ω to 100 G Ω
> 100 GΩ
not specified
5 %
20 %
not specified
1000 V < 200 kΩ
200 k Ω to 20 G Ω
20 G Ω to 200 G Ω
> 200 GΩ
not specified
5 %
20 %
not specified
2500 V < 200 kΩ
200 k Ω to 50 G Ω
50 G Ω to 500 G Ω
> 500 GΩ
not specified
5 %
20 %
not specified
5000 V < 200 kΩ
200 k Ω to 100 G Ω
100 G Ω to 1 T Ω
> 1 TΩ
not specified
5 %
20 %
not specified
10000 V
(Fluke1555 only)
< 200 kΩ
200 k Ω to 200 G Ω
10 G Ω to 2 T Ω
> 2 TΩ
not specified
5 %
20 %
not specified
Bar Chart Range 0 to 1 T Ω
Accuracy of insulation test voltage -0%,+10%, at a load current of 1 mA
Inductive AC current suppression 2 mA maximum value

Charging rate of capacitive load

5s/μF

Discharge rate of capacitive load

1.5s/μF

Leakage current measurement

Range: 1 nA to 2 mA

Accuracy: ± (5 % + 2 nA)

Capacitance measurement

Range: 0.01 uF to 15.00 μ F

Accuracy: ± (15% reading+0.03 μ F)

timer

Range: 0-99 minutes

Resolution accuracy:
Setting: 1 minute
Tips: 1 s

Live circuit warning

Warning range:
30 V to 660 V ac/dc,
50/60 Hz

Voltage accuracy:
± (15 % + 2 V)

General technical parameters

display 75 mm x 105 mm
power supply 12V lead-acid rechargeable battery, Yuasa NP2.8-12
Charger input (AC) Charger input (AC) 85 V to 250 V AC 50/60 Hz 20 VA
This Class II (double insulated) instrument provides a Class 1 (grounded) power cord. The protective grounding terminal (grounding pin) is not connected internally. The additional sales are only used to increase the plug retention capacity.
size 170 mm x 242 mm x 330 mm (6.7 in x 9.5 in x 13 in)
weight 3.6 kg (7.94 lb)
operation temperature -20 º C to 50 º C (-4 º F to 122 º F)
storage temperature -20 º C to 65 º C (-4 º F to 149 º F)
humidity 80% below 31 º C, 50% linearly decreasing to 50 º C
altitude 2000 m
Sealing performance of the shell IP40
Input overload protection 1000 V ac
electromagnetic compatibility EN 61326
authentication
safety CAT III 1000 V, CAT IV 600 V
pollution degree 2

Electrical technical parameters

The prescribed accuracy of the tester is the accuracy within one year after calibration at operating temperatures between 0 ° C and 35 ° C. When the working temperature exceeds this range (-20 ° C to 0 ° C and 35 ° C to 50 ° C), the accuracy value needs to be increased by ± 0.25%/° C, but within the 20% error range, it needs to be increased by ± 1%/° C.

Fluke1550C/Optional set:

FLUKE 1555/Kit 10KV Insulation Tester Kit

FLUKE 1555 10KV Insulation Tester

FLUKE 1550C/Kit 5KV Insulation Tester Kit

FLUKE 1550C 5KV Insulation Tester Kit

For detailed product information/quotations, please go online or we can:


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!