E3-P: PCB dedicated detector
HeLeeX E3-P is a high-performance energy dispersive X-ray fluorescence spectrometer (EDXRF) that has been comprehensively optimized in terms of instru
Product details

Radiation protection

● Sample cover embedded with lead plate to shield X-rays

Radiation warning signs

The instrument has been tested by an authoritative third-party and the X-ray dose rate fully complies with GB18871-2002 "Basic Standards for Ionizing Radiation Protection and Radiation Source Safety"


hardware technology

X-ray irradiation type, laser focusing adjustable sample chamber, for large and irregular samples, no need to disassemble and polish, can be directly tested

Modular collimator, equipped with collimators of different materials according to the analyzed elements, thereby reducing the impact of collimators on the analyzed elements and improving element resolution

The minimum spot size is 0.2mm, which can accurately locate small test points in various samples, avoid material interference, and provide more accurate measurement results

Aerodynamic design accelerates the cooling of the light tube, effectively reducing the internal temperature of the instrument; Silent Design

The circuit system complies with EMC and FCC testing standards


Software Technology (HeLeeX ED Workstation V3.0)

Analysis elements: elements between Na~U

Analysis time: 90 seconds

● Simple interface, modular design, clear functions, and easy operation

One click backup, one click restore, and one click clean function of data to protect user data security

According to different matrix samples, three algorithms are equipped to increase the accuracy of sample testing

Equipped with an open analysis model function, customers can create their own working models.

detector

Type: X123 detector (original imported high-performance electrically cooled semiconductor detector)

● Be window thickness: 1mil

● Crystal area: 25mm2

● Best resolution: 145eV

● Signal processing system: DP5


X-ray tube

Voltage: 0-50V

● Maximum current; 2mA

Maximum power: 50W

Target material: Mo

● Be window thickness: 0.2mm

● Service life: greater than 2w hours


high voltage power supply

Output voltage: 0-50Kv

● Filament current 0-2mA

Maximum power: 50w

Ripple factor: 0.1% (p-p value)

8-hour stability: 0.05%


camera

● Focal length: Micro focal length

● Driver: No driver required

● Pixel: 5 million pixels


Collimator, filter

● System: Quick disassembly collimator, filter system

● Material: Multiple materials collimator

Spot size: available in sizes of Φ 0.2mm, Φ 1.0mm, Φ 2.0mm, and Φ 4.0mm

● Combination: Multiple filters (automatically switched by software), collimator combination


Cross shaped laser head

Spot shape: Cross line

Output wavelength: Red light 650nm

Optical lens: Glass lens

● Size: Φ 10 × 30mm

● Divergence angle: 0.1-2mrad

● Working voltage: DC 5V

Output power:<>

Working temperature: -10~50 ℃

Storage temperature: -40-85 ℃


Other accessories

● Switching power supply: imported high-performance switching power supply

● Cooling fan: Imported low-noise, high air volume fan

● Dimensions: 360 mm x 600mm x 385 mm (length x width x height)

Sample compartment size: 360mm x 400mm x 160 (length x width x height, height can be customized)

● Instrument weight: 50kg

Power supply: AC220V/50Hz

Maximum power: 330W

Working temperature: 15-30 ℃

Relative humidity: ≤ 85%, no condensation

Coating testing in various PCB boards;

● Coating testing in various plug connections;

● Coating testing in the hardware industry;