The walk-in drug sample retention laboratory, infusion product sample retention laboratory, and drug stability laboratory are scientifically designed to create a long-term stable temperature, humidity, and lighting environment for evaluating the failure of bulk drugs. They are suitable for pharmaceutical companies to conduct accelerated testing, long-term testing, and high humidity testing of drugs and new drugs. They are the best choice for pharmaceutical companies to conduct large-scale drug storage and stability testing, facilitating long-term moisture resistance cycling testing of large quantities of drugs. National Free Service Hotline:.
Product features:
1. Imported touch sensitive color LCD operation screen, can switch between Chinese and English freely,100A program for users to set/save and display various operational data.
2.Adopting TMHM balanced temperature and humidity control scheme, the operation is stable, safe and reliable.
3.The unique air duct circulation system ensures uniform temperature and humidity distribution inside the laboratory.
4.A comprehensive safety protection device ensures the safe and reliable operation of the product.
5.The data is recorded in the fault diagnosis display. When the test chamber malfunctions, the dynamic display screen will show fault information. It can be connected to a printer or RS485 communication interface, and run computer software to record temperature and humidity time curves in real time, providing a strong guarantee for storing and replaying experimental process data.
6.Anti lock device, allowing people to safely enter and exit the laboratory.
2、 Refrigeration and air duct system
▲ The freezer adopts imported compressors from Europe and America, and uses environmentally friendly refrigerants (R134A, R404)
The refrigeration system adopts a binary low-temperature circuit system design and uses different compressors to work in different temperature ranges to increase the service life of the equipment.
▲ By utilizing a multi wing air supply fan for strong air circulation, any dead corners can be avoided, and the temperature and humidity distribution in the testing area can be evenly distributed.
The air circulation adopts a side blowing air return design, with wind pressure and speed that meet the test standards, and can quickly stabilize the temperature and humidity of the switch.
Fully independent heating, cooling, humidification, and dehumidification systems can improve efficiency, reduce testing costs, extend lifespan, and lower failure rates.
3、 Meet the requirements:
Meet the ICH2005 Q1A (2) guidelines/GMP 2010 version of the Chinese Pharmacopoeia stability test conditions:
1. Accelerated test: 40 ℃± 2 ℃/75% RH ± 5% RH
2. Intermediate conditions: 30 ℃± 2 ℃/65% RH ± 5% RH
3. Long term test: 25 ℃± 2 ℃/60% RH ± 5% RH or 30 ℃± 2 ℃/65% RH ± 5% RH
4、 Technical specifications: National Unified Customer Service Hotline:
Equipment model
|
EWR-8P-A
|
EWR-10P-A
|
EWR-14P-A
|
EWR-18P-A
|
EWR-35P-A
|
EWR-43P-A
|
EWR-64P-A
|
|||
Test area size (WxHxD), cm
|
160x240x195
|
210x240x195
|
300x240x195
|
390x240x195
|
390x240x375
|
480x240x375
|
480x240x555
|
|||
A
|
Dimensions (WxHxD), cm
|
205x260x205
|
205x260x205
|
340x260x205
|
430x260x205
|
430x260x385
|
520x260x385
|
520x260x565
|
||
B
|
215x270x215
|
260x270x215
|
350x270x215
|
440x270x215
|
440x270x395
|
530x270x395
|
530x270x575
|
|||
C,D
|
225x280x225
|
270x280x225
|
360x280x225
|
450x280x225
|
450x280x405
|
540x280x405
|
540x280x585
|
|||
Test area size ㎡
|
8
|
10
|
14
|
18
|
35
|
43
|
64
|
|||
scope of work
|
Temperature: 0 ℃~65 ℃ humidity: 30~95%RH
|
|||||||||
material
nature |
Internal material
|
SUS304Embroidered steel plate
|
||||||||
External material
|
SUS304Non embroidered steel plate+powder baking paint
|
|||||||||
Thermal insulation material
|
PUAnd insulation cotton
|
|||||||||
set up
have sexually ability |
Analysis accuracy
|
Temperature: 0.01 ℃ Humidity: 0.1% R.H
|
||||||||
Control accuracy
|
Temperature: ± 0.3 ℃ Humidity: ± 1.5% R.H
|
|||||||||
temperature uniformity
|
≤±2℃
|
|||||||||
temperature fluctuation
|
±2℃
|
|||||||||
Humidity error
|
+2/-3%RH
|
|||||||||
Cooling time
|
30min
|
|||||||||
system
interconnected system tie construct |
control system
|
The drug stability laboratory series adopts a Japanese imported ultra sensitive liquid crystal (LCD) touch screen
|
||||||||
Extended products
|
Drug stability test chamber, constant humidity test chamber, drug constant temperature and humidity test room
|
|||||||||
Heating system
|
SUS304Stainless steel high-speed electric heater
|
|||||||||
Humidification method
|
Surface evaporation method
|
|||||||||
Cooling system
|
Original European and American refrigeration compressor+evaporator+air-cooled condenser
|
|||||||||
circulatory system
|
Stainless steel fan blades, low noise, multi wing circulating fan
|
|||||||||
Safety device
|
Leakage and power-off protection, compressor overpressure, overheating and overcurrent protection, overload fuse protection, fan overheating protection, sound and light alarm, etc.
|
|||||||||
Other accessories
|
Multi layer reinforced glass window, test hole (50mm), action indicator light, interior lighting, recorder (optional))
|
|||||||||
Note: It can be made according to the size requested by the customer to meet their requirements.
|