Delger detection tube
Since the first Delger detection tube was introduced in the early 19th century, it has a history of more than 90 years. The Delger detection tube syst
Product details

Many years ago, only a few gases could be detected through detection tubes, and the application field has always been focused on detecting whether toxic and harmful gases in the workplace are within the exposure limit range. With the continuous reduction of exposure limits in the workplace, the development of more sensitive Delger detection tubes has become inevitable. Currently, Delger has developed over 300 types of detection tubes, ranging from qualitative detection of carbon monoxide gas to accurate detection of over 500 toxic and harmful gases,Delger detection tubeIt has been widely applied in fields such as petrochemicals, firefighting, ships, environmental monitoring, etc.

德尔格检测管特点

There are also various types of detection tubes, such as scale detection tubes, colorimetric tubes, ampere bottle detection tubes, synchronous detection tubes, etc., providing multiple solutions for the detection of different toxic gases. Delger is constantly expanding its detection tube product line and making it the company's traditional detection product.Delger detection tubeCan be used in conjunction with Dr ä ger Accuro hand pump 6400000 or X-act 5000 automatic sampling pump.It can be called a golden partner, as it is a constant volume pumping device designed specifically for Delger detection tubes.

The detection tube and Accuro hand pump can provide accurate detection results. The measurement error of most Delger detection tubes does not exceed ± 10%. Each batch of detection tubes is calibrated separately to ensure quality, and each batch of detection tubes is regularly tested during the two-year storage period to ensure the accuracy of the entire service life of the detection tubes.Not all detection tubes are the same!

The wider diameter of the detection tube makes reading very convenient. The large spacing scale markings provide clear and decisive measurement results. The color change of the reagent inside the tube can be easily indicated by the length of the entire coloring agent. Many detection tubes have two sets of calibrated scales, so results can be easily obtained without further calculation.You can see the change on your own!

Although many Delger detection tubes require multiple samples, the results are obtained in a very short time. Not only can you benefit from rapid analysis, but large sample sizes are also more helpful in obtaining accurate results.A detection tube that only extracts a gas sample once does not always provide results quickly!

Compared to other manufacturers, it can detect more gases and has a wide measurement range. Delger has over 300 types of detection tubes that can accurately detect more than 500 types of gases. For health and safety reasons, you can test the ambient air using specific instruments that can detect flue gas, car exhaust, sealed gas samples, pollutants in compressed air, and dissolved substances in water. Other special detection tubes can also be used for long-term or entire work shifts to measure daily exposure levels.There are many types of Delger detection tubes!

The Delger Accuro air pump does not require lubricating oil like a piston air pump. The air pump is made of corrosion-resistant non-metallic materials. It can withstand intense operation and harsh chemical environments. The Delger detection tube has been pre calibrated for two years. The Delger detection tube only needs to be stored away from direct sunlight and below 25 ℃. Any temperature controlled office meets the requirements.Delger makes gas detection very easy!

德尔格检测管与采样泵(电动 手动)

Delger common detection tube range, order number, etc

name

range

order No

hydrogen sulfideH2S0.2/a

0.2-5ppm

8101461

hydrogen sulfideH2S0.2/b

0.2-6ppm

8101991

hydrogen sulfideH2S0.5/a

0.5-15ppm

6728041

hydrogen sulfideH2S1/c

1-200ppm

6719001

hydrogen sulfideH2S1/d

1-200ppm

8101831

hydrogen sulfideH2S2/a

2-200ppm

6728821

hydrogen sulfideH2S2/b

1-60ppm

8101961

hydrogen sulfideH2S5/b

5-60ppm

CH29801

hydrogen sulfideH2S100/a

100-2,000ppm

CH29101

hydrogen sulfideH2S0.2%/A

0.2-7Vol.%

CH28101

hydrogen sulfideH2S0.2%/a

2-40Vol.%

8101211

hydrogen sulfide+sulfur dioxideH2S+SO20.2%/A

0.2-7Vol.%

CH28201

mercaptanMercaptan0.5/a

0.5-5ppm

6728981

mercaptanMercaptan0.1/a

0.1-15ppm

8103281

mercaptanMercaptan20/a

20-100ppm

8101871

mercury vaporMercuryVapor0.1/b

0.05-2mg/m3

CH23101

Methyl methacrylate vinegarMethylAcrylate5/a

5-200ppm

6728161

Methyl bromideMethylBromide0.2/a

0.2-8ppm

8103391

Methyl bromideMethylBromide0.5/a

0.5-30ppm

8101671

Methyl bromideMethylBromide3/a

3-100ppm

6728211

Methyl bromideMethylBromide5/b

5-50ppm

CH27301

dichloromethaneMethleneCholride100/a

100-2,000ppm

6724601

Natural gas testing(5) Natural Gas Test(Methane)(5)

qualitativeQualitative

CH20001

Four carbon based nickelNickelTetracarbonyl0.1/a(9)

0.1-1ppm

CH19501

nitric acidNitricAcid1/a

1-50ppm

6728311

nitrogen dioxideNO20.5/c

0.5-25ppm

CH30001

nitrogen dioxideNO22/c

2-100ppm

6719101

Nitrous acid smokeNitrousFumes0.5/a

0.5-10ppm

CH29401

Nitrous acid smokeNitrousFumes2/a

2-100ppm

CH31001

Nitrous acid smokeNitrousFumes20/a

20-500ppm

6724001

Nitrous acid smokeNitrousFumes50/a

50-2,000ppm

8101921

Nitrous acid smokeNitrousFumes100/c

100-5,000ppm

CH27701

MistOilMist1/a

1-10mg/m3

6733031

alkeneOlefins0.05%/a

0.06-3.2Vol.%propylene

Propylene

0.04-2.4Vol.%buteneButylene

CH31201

Organic arsenic compounds and arsine Organic Arsenic Compound sand Arsine

0.3mgorg.arsenic/m3

CH26303

Organic alkaline nitrides Organic Basic Nitrogen Compounds

1mg/m3

CH25903

oxygenO25%B(8)

5-23Vol.%

6728081

oxygenO25%/c

5-28%

8103261

ozoneOzone0.05/b

0.05-0.7ppm

6733181

ozoneOzone10/a

10-300ppm

CH21001

pentanePentane100/a

100-1,500ppm

6724701

tetrachloroethylenePerchloroethylene0.1/a

0.1-4ppm

8101551

tetrachloroethylenePerchloroethylene2/a

2-300ppm

8101501

tetrachloroethylenePerchloroethylene10/b

10-500ppm

CH30701

Precautions for Delger detection tube:

1. Do not use the Delger detection tube when it expires. Dispose of the testing tube or packaging according to local regulations and return it. Unauthorized personnel are not allowed to come into contact.

2. The substance inside the detection tube is toxic. Do not swallow. Avoid skin or eye contact. Be careful of glass shards when opening the detection tube.

3. The detection tube can only be used in conjunction with the following Delger pumps: Accuro hand pump (6400000) and X-act 5000 automatic sampling pump. If other pumps are used, measurement errors may occur. The single sampling volume of the Delger manual sampling pump is 100ml, and other brands of detection tubes can use Delger manual pumps for sampling.

4. The test results are only applicable to the date and location measured at that time.

5. Avoid contact between the filling material of the tube and the skin. The filling material is corrosive. Isolate unauthorized individuals present.

6. The packaging tape includes the ordered quantity, shelf life, storage temperature, and serial number. Please provide the serial number when querying.

Validity period of Delger detection tube:

Many users are very concerned about the expiration date of Delger detection tubes. Delger detection tubes circulating in China generally have two expiration dates.

1. It is the shelf life of the cold storage, which is printed on the label paper of the detection tube, usually in black font. The Delger inspection tube is transported through cold chain after leaving the factory in Germany, which provides higher safety protection for the quality of the inspection tube. After arriving in China, it is still stored in a cold storage, and the black printed date is the recommended maximum storage date in the cold storage. Generally, the storage period in a cold storage is 18 months.

2. The Delger detection tube also has a second date stamped in blue. There are two types of this date: one is stamped with the outbound date, which can be stored for another two years in a normal environment after outbound. There is also a type of blue stamp date that is a countdown date, and the expiration date after two years is calculated based on the date it has been shipped out.

Previously, many users didn't quite understand why there were two expiration dates for this product. Now, they understand and also know why Delger detection tubes have good quality and are accurate to use.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!