Shanghai Zequan Technology Co., Ltd
Home>Products>DB5301A DaqPro 8-channel Collector
DB5301A DaqPro 8-channel Collector
Instrument Introduction: DB5301A DaqPro8 Channel Collector is a compact and efficient independent collector, and the measured values can be displayed
Product details

Instrument Introduction





DqPRO_DB5301A_01.jpg

DB5301AtypeDaqPro 8The channel collector is a compact and efficient independent collector, and the measured values can be displayed in graphical form on the host. The instrument can be set up separately or throughDaqLabSoftware for data download and advanced settings.











Instrument characteristics





DqPRO_DB5301A_02.jpg

ØAt most, it can be accurately measured16Bit resolution8An input signal

ØAn alarm output

ØCan display measured values graphically

ØThe maximum sampling frequency can reach4000per second

ØEach sensor can be individually configured

ØThe storage space is512kb RAM

Ørechargeable7.2VOn Battery













Main technical parameters



DqPRO_DB5301A_03.jpg

ØInput Type

  • 4to20mAsensor

Range: 4 to 20mA

Resolution: 47.6 μ A

Accuracy: ± 0.5%

Loop impedance: 21 Ω

  • 0to50mVsensor

Range: 0 to 50mV

Resolution: 3 μ V

Accuracy: ± 0.5%

  • 0to10Vsensor

Range: 0 to 10V

Resolution: 200 μ V

Accuracy: ± 0.5%

  • NTCtemperature sensor

NTC: 10/100 K Ω resistor

Range: -25 to 150 ℃

Resolution: 0.05 ℃

Accuracy: ± 0.5%

  • PT-100temperature sensor

Range: -200 to 400 ℃

Resolution: 0.1 ℃ (7m Ω)

Accuracy: -200 to -50 ℃ ± 0.5%; 50 to 400 ℃ ± 0.5%- 50 to 50 ℃± 0.5 ℃

  • JType thermocouple temperature sensor

Range: -200 to 1200 ℃

Resolution: 0.1 ℃

Accuracy: -200 to -50 ℃ ± 0.5%; 50 to 1200 ℃± 0.5%- 50 to 50 ℃± 0.5 ℃

Cold end temperature compensation: ± 0.3 ℃

  • KType thermocouple temperature sensor Range: -250 to 1200 ℃

Resolution: 0.1 ℃

Accuracy: -250 to -50 ℃ ± 0.5%; 50 to 1200 ℃± 0.5%- 50 to 50 ℃± 0.5 ℃

Cold end temperature compensation: ± 0.3 ℃

  • TType thermocouple temperature sensor

Range: -200 to 400 ℃

Resolution: 0.1 ℃

Accuracy: -200 to -50 ℃ ± 0.5%; 50 to 400 ℃ ± 0.5%- 50 to 50 ℃± 0.5 ℃

Cold end temperature compensation: ±0.3

  • Pulse counter (port only)1 Range: 0 to 65000

Resolution: 1 count

Frequency range: 0 to 25Hz

Input signal: 0 to 5V

Input impedance: 470 Ω

  • Frequency (limited to ports only)1

Range: 20Hz to 4KHz

Input signal: 0 to 5V

Input impedance: 470 Ω

  • Built in temperature sensor

Range: -25 to 70 ℃

Resolution: 0.1 ℃

Accuracy: ± 0.5 ℃

  • generalAtoD

Noise: 30 μ V

Internal linear error: ± 0.08% FSR

Calibration error: 0.1%

  • Open collector output

Maximum current source: 50mA (with fuse)

Maximum input voltage: 5V

Input impedance: 50 Ω

ØHardware parameters

  • communication USB1.1

  • Instrument power supply (three options available)

Built in rechargeable 7.2V nickel hydrogen battery

Optional external 12V DC power input

  • operate temperature 0 to 50 ℃

  • Sampling settings

Memory: 512KB

Analog channel sampling rate: variable, ranging from 4000 per second to once per hour (for a single channel)

Simulated sampling resolution: 16 bits

Channel spacing: 80dB

  • Host placement box

ABS clinker box

Size: 18.2 x 10 x 2.8 cm

Weight: 450g

  • Compatibility standards CE/FCC













Place of Origin:Fourtec, USA





Online inquiry