Product Features
Adopting imported high-quality silicon piezoresistive sensors, integrated compact structure, dedicated deepwater sealing technology process, ultra long
Deep well design (2000m) with analog or digital signal output, high measurement accuracy (0.05%), stable and reliable performance,
Suitable for oil, natural gas, coalbed methane extraction, geological exploration monitoring, and mine water level measurement
Working principle
The pressure sensor probe is placed in the measured liquid and subjected to a certain static pressure of the medium (P). This pressure is related to the measured liquid
The liquid level height (h, m) of the body is proportional to P=ρ gh (Pa), where ρ is the specific gravity of the medium (g/cm3) and g is
The local gravitational acceleration (m/s2) is constant for the measured medium and location, where ρ and g are constant. The electronic components of the transmitter will apply pressure
The liquid level pressure signal measured by the force sensor is transmitted to the display instrument, and the liquid level signal of the medium is displayed through circuit conversion.
Technical Parameter
·Measurement range
Minimum 0~350m, maximum 0~2000m
·Measurement accuracy
(Comprehensive errors include linearity, hysteresis, and repeatability)
Simulated 0.2% FS; Intelligent 0.2% FS, 0.1% FS, 0.5% FS
·Long term stability
Better than 0.03% per year
·Allowable medium temperature
-20℃~90℃
·Allow ambient temperature
-40℃~85℃
·Allow storage temperature
-40℃~85℃
·Temperature influence
0.2%, 0.1%, 0.075% accuracy level -20 ℃~80 ℃, every 10K+0.1%, other temperature ranges every 10K ± 0.2%
0.05% accuracy level, every 10K ± 0.02%
·Material of the part in contact with the medium
·silicon piezoresistive sensor
Corrugated film 316L (special requirements agreed upon)
·Measuring sensor housing
Stainless steel 316L
·Invest in extension cables
Plastic PE
·Sensor counterweight
Stainless steel 304 (special requirements agreed upon)
·Material of non-contact parts with the medium
·Junction box
ABS plastic IP66/IP67
·Process Connection Standard
Nickel plating on carbon steel
·Working voltage
(12.5~30V DC)
·Signal output
Analog type: 2-wire system 4-20mA
Intelligent two-wire 4-20mA with HART communication protocol
·Cable entry hole
Internal thread M20 × 1.5 (PVC junction box)
·Analog cable
Three core instrument cable intelligent cable: It is recommended to use shielded twisted pair cable for wiring
·Allow environmental humidity
100%HR
Exterior structure
Electrical connection
load characteristics
Communication protocol
DB series intelligent liquid level gauge with remote communication function
Order Selection Table
Overlay a digital signal on the 4-20mA two-wire output signal of the level gauge transmitter to achieve the HART communication protocol standardSeveral functions. The functional implementation includes the following: manual operation using the HART communication protocol or a microcomputer (requires configuration)The HART communication protocol software interface can remotely calibrate the zero point and full range values of the liquid level transmitter, display the temperature value of the medium, and indicate whether it has been usedPressure level value, adjust damping value, achieve self diagnostic function of the measurement system, display various fault states represented by fault codesLocation and reason.