Purpose:
The new CX402-T415 (with 4M cable external temperature probe, 15ML ethylene glycol bottle) vaccine cold chain grade Bluetooth low-power room temperature recorder can be used to monitor indoor temperature, temperature inside the freezer, or other temperature controlled environments. Data communication is transmitted wirelessly to mobile devices via Bluetooth, which is simple and convenient Through the software, it is easy to view data, monitor host status, set warnings, and create PDF reports for secure sharing. The built-in LCD display screen can display temperature data, the visual warning function can be used to monitor temperature deviation, and the built-in probe can monitor room temperature.
characteristic:
·Easy to read, current temperature and daily temperature, maximum temperature and minimum temperature;
·Visual automatic alarm function;
·Bluetooth data transmission and warning status;
·Quick setup and data download;
·High reliability temperature reading with an accuracy of+/-0.5 ℃;
·Rechargeable batteries can ensure local power loss;
·Several ethylene glycol bottles/probes to choose from;
Technical specifications:
host | |
transmitted power |
1 mW (0 dBm) |
Range |
30.5 meters |
Wireless transmission standard |
Bluetooth Low Energy (Smart Bluetooth) |
operation temperature |
-30 ℃ to 70 ℃, |
Working humidity |
0-95% (non condensing) |
Collection interval |
1 second -18 hours |
time accuracy |
± 1 minute/month, at 25 ℃ |
Type |
Typical usage for 1 year (1-minute collection interval) |
Memory |
128KB |
Data download time |
60 seconds, depending on the distance between the data acquisition and the equipment |
LCD operating temperature |
0℃- 50℃ |
size |
9.4 x 4.5 x 2.59 cm |
Waterproof grade |
IP54 |
External temperature probe (4M cable, 15ML ethylene glycol bottle) | |
measuring range |
-40 ℃ to 100 ℃ |
measurement accuracy |
± 0.5 ℃ (-15 ℃ to 80 ℃), ± 1.0 ℃ (-40 ℃ to -15 ℃), ± 0.7 ℃ (80 ℃ to 100 ℃) |
resolution |
At 25 ℃, 0.024 ℃ |
temperature drift |
<0.1 ℃/year |
reaction time |
20 minutes, typical 90% (1m/s airflow) |
Length |
4M |
Room temperature sensor | |
measuring range |
-30℃~ 70℃ |
accuracy |
± 0.5 ℃ (-15 ℃ to 70 ℃), ± 1.0 ℃ (-30 ℃ to -15 ℃) |
resolution |
At 25 ℃, 0.024 ℃ |
temperature drift |
<0.1 ℃/year |
reaction time |
15 minutes, typical 90% (1m/s airflow) |
Place of Origin:America