BondMaster 600 Multi Mode Adhesive Tester
|
☆ Measurement range: 1mm to 10160mm
|
☆ Operating frequency: 635 m/s to 15240 m/s
|
☆ Detection accuracy: 0.2 MHz to 26.5 MHz
|
☆ Indication error: 0.01mm
|
Product Introduction
----------------------------------------------------------------------
BondMaster 600Multi mode adhesive tester
Simple and intuitive operation, high-quality performance
BondMaster 600This powerful detector combines multi-mode adhesive detection software with ultra advanced digital electronic devices, providing users with extremely clear and stable high-quality signals. Users can use it to detect the adhesion of honeycomb structure composite materials, metal laminated materials, or laminated composite materialsBondMaster 600Performing extremely simple operations is not only thanks to the quick access keys and simplified interface equipped with the detector, but also the pre-set settings provided by the instrument for common applications facilitate the user's operation process.BondMaster 600The user interface of has been improved, and its workflow has been simplified, allowing users of all levels to archive test results and create reports.
BondMaster 600The handheld adhesive tester is equipped with a5.7InchesVGAWhen transitioning to full screen mode, the enhanced resolution and brightness of the display screen make the display brighter and clearer. No matter what display mode or detection method the user is currently using, simply clicking the full screen mode conversion button will activate the full screen mode.BondMaster 600The adhesive tester is equipped with various standard testing methods, including one transmitter and one receiver RF, one transmitter and one receiver pulse, one transmitter and one receiver sweep frequency, resonance, and significantly improved mechanical impedance analysis(MIA)Method.
Compact and portable, extremely lightweight, in line with ergonomic requirements
BondMaster 600The ergonomic design allows users to easily detect difficult to reach detection areas. For testing conducted in extremely small spaces, using a wrist strap installed by the manufacturer not only provides users with great comfort during operation, but also allows them to always control the most important functions.
Verified on-site
BondMaster 600The casing of the instrument is based on a body design that has been field validated and is sturdy and durable. As is well known, instruments with this body structure can operate normally under the harshest and most demanding testing conditions.BondMaster 600The battery of the instrument can provide long-term power supply, and its shell has sealing and waterproof properties. The corners of the instrument are equipped with protective covers with extremely high anti friction strength, and a dual function bracket is installed on the back panel/The hanger, therefore, can be said to be a highly valuable tool for completing challenging detection applications.
Main characteristics
lDesigned to meet IP66 requirements.
lLong term battery operation time (up to 9 hours).
lCompatible with existing BondMaster probes (PowerLink) and probes from other manufacturers.
l5.7-inch bright color VGA display screen.
lFull screen options in all display modes.
lA pre-set intuitive interface with specialized applications.
lUse the RUN key to instantly switch display modes.
lNewly added SCAN view function (sectional view).
lNewly added Spectrum view with new frequency tracking function.
lGain adjustment function of shortcut access keys.
lAll settings configuration pages.
lThere are at most two real-time readings.
lStorage capacity up to 500 files (programs and data).
lPreview of onboard files.
There are two types of instruments available, which are highly flexible and compatible
BondMaster 600 comes in two models, suitable for different needs in composite material bonding testing. The basic model includes all one send one receive modes, while the B600M model provides users with all adhesive testing methods. Upgrading from the basic model of the instrument to a multi-mode model can be done remotely.
Both BondMaster 600 models are compatible with existing Olympus BondMaster probes, including those utilizing PowerLink technology. We also offer optional adapter cables to make the instrument compatible with probes produced by other manufacturers.
application |
Suggested way to use |
General debonding of skin and honeycomb core in honeycomb composite materials |
One send, one receive (RF or pulse) |
Debonding of skin and honeycomb core in composite materials with conical or irregular geometric shapes |
One send, one receive (sweep frequency) |
Small area debonding of skin and honeycomb core in honeycomb structure composite materials |
MIA(Mechanical impedance analysis) |
Identify repair areas in honeycomb composite materials |
MIA(Mechanical impedance analysis) |
General detection of delamination in composite materials |
resonance |
Testing the adhesion of metal laminated materials |
resonance |
characteristic |
B600(Basic) |
B600M(Multi mode) |
Calibration of frozen signal |
√ |
√ |
Real time reading |
√ |
√ |
Application selection |
√ |
√ |
PowerLinkSupport for probes |
√ |
√ |
One send one receive RF and pulse modes |
√ |
√ |
One send, one receive, sweep frequency |
√ |
√ |
Mechanical impedance analysis(MIA)Mode |
√ |
|
Resonant mode |
√ (including cables) |
|
Calibration menu (resonance and mechanical impedance analysis modes) |
√ |
technical specifications
General specifications |
|
External dimensions (width) × high × Thick) |
236 mm×167 mm×70 mm |
weight |
1.70Kilograms, including lithium-ion batteries |
Standard or instruction |
US military standards810G、CE、WEEE、FCC(United States)IC(Canada)RoHS(China)RCM(Australia and New Zealand) andKCC(South Korea) |
Power requirements |
ACMain power supply:100 VAC~120 VAC、200 VAC~240 VAC,50 Hz~60 Hz |
Input and output |
1individualUSB 2.0Peripheral device ports1A standardVGAAnalog output port1A device with analog output15needleI/OPort (public port)3An alarm output. |
environment condition |
|
working temperature |
–10 °C~ 50 °C |
Storage temperature |
0°C~ 50°C(with battery);-20°C~ 70°C(without battery) |
IPgrade |
Design conforms toIP66Standard requirements. |
Battery |
|
Battery type |
Single lithium-ion rechargeable battery orAAType alkaline battery (can be installed)8In the battery compartment of a battery. |
Battery working time |
8reach9hour |
display |
|
Size (width) × High; Diagonal) |
117.4 mm×88.7 mm;146.3 mm |
type |
wholeVGA(640 x 480Pixel Color TranslucentLCD(LCD display)) |
pattern |
Normal or full screen,8A color screen setting.RUNThe (Display Mode) key can switch between various display modes on the screen. |
Grid and Display Tools |
5Grid options, crosshair (only available)X-YView) |
Connectivity and Memory |
|
PCMachine software |
BondMaster PCSoftware, included in the basicBondMaster 600In the set. Users canBondMaster PCYou can view saved files in the software and also print reports through the software. |
data storage |
500A file with onboard preview function that can be selected by the user. |
Interface |
|
language |
English, Spanish, French, German, Italian, Japanese, Chinese, Russian, Portuguese, Polish, Dutch, Czech, Hungarian, Swedish, and Norwegian. |
application |
The application selection menu helps users to quickly and conveniently configure in various modes. |
Real time reading |
Up to two real-time readings that reflect the characteristics of the measurement signal can be selected (the list of available readings depends on the selected mode) |
Supported probe types |
|
Probe type |
One send one receive probe, mechanical impedance analysis probe (only)MIA-B600M), as well as resonant probes (only available)B600M).BondMaster 600Instruments are not only related toBondMasterofPowerLinkProbe and non probePowerLinkThe probe is fully compatible and also compatible with products from other major probe and accessory suppliers. |
Adhesive testing technical specifications (all)BondMasterModel) |
|
Probe interface |
11needleFischer |
gain* |
0 dB~100 dBThe increment is0.1or1 dB. |
rotate* |
0° ~ 359.9°, increment is0.1° or1°. |
Scan View* |
stay0.520 sreach40 sVariable between them. |
low pass filter* |
6 Hz~300 Hz |
Probe driver |
User adjustable low, medium, and high settings |
Variable afterglow retention* |
0.1Seconds to10second |
Variable display clearing* |
0.1Seconds to60second |
Available alarm types* |
3Alarm simultaneously. There are the following options: box alarm (rectangular), polarity alarm (circular), sector alarm (pie shaped), scan alarm (time-based), and spectrum alarm (frequency response). |
Reference point* |
Up to25Record of user-defined points |
One send, one receive technical specifications (all)B600Model) |
|
Supported one send one receive mode |
The mode that can be selected by the user. You can choose radio frequency (burst pulse), pulse (envelope), or sweep frequency (frequency sweep) |
frequency range |
1 kHz~50 kHz(RF, pulse) or1 kHz~100 kHz(Sweep frequency) |
gain |
0 dB~70 dBThe increment is0.1or1 dB. |
sluice gate |
10 μs~ 7920 μs, adjustable, with a step distance of10 μsThe new automatic gate mode can automatically detect the maximum wave amplitude. |
Frequency tracking* |
At most2User adjustable markers for monitoring from swept frequency images2A specific frequency. |
Mechanical impedance analysis(MIA)Technical specifications (only)B600M) |
|
Calibration Wizard |
Calibration menu, based on a simple“BAD PART”(Unqualified workpieces) and“GOOD PART”Measurement of qualified workpieces to determine the optimal frequency for application. |
frequency range |
2 kHz~50 kHz |
Technical specifications for resonance (only)B600M) |
|
Calibration Wizard |
Calibration menu, determine the optimal frequency based on the response of the probe. |
frequency range |
1 kHz~500 kHz |
* Specific detection modes have limitations within this range. |