Jiangsu Borhui Automation Equipment Co., Ltd
Home>Products>Blue Ocean Huateng V6-H high-performance vector control/torque control frequency converter (0.75kw-1000kw)
Blue Ocean Huateng V6-H high-performance vector control/torque control frequency converter (0.75kw-1000kw)
V6-H is a high-performance vector control/torque control frequency converter, with modular software and hardware functions that meet the needs of high
Product details

V6-H is a high-performance vector control/torque control frequency converter, with modular software and hardware functions that meet the needs of high-end industries such as lifting, hoisting, papermaking, chemical fiber, elevators, rolling mills, and packaging.
Vector Control 1:
It has excellent performance of vector control and is insensitive to motor parameters.
Starting torque: 0.50Hz 180% rated torque
Speed range: 1:100
Steady speed accuracy: ± 0.5%
0.50Hz can control the motor to operate stably at 150% of its rated torque.
◆ No encoder speed feedback vector control 2:
The precise sensorless vector control technology truly achieves decoupling of AC motors, making the operation control DC motorized.
Starting torque: 0.25Hz 180% rated torque
Speed range: 1:200
Steady speed accuracy: ± 0.2%
0.25Hz can control the motor to operate stably at 150% of its rated torque.
◆ Encoder speed feedback vector control 2:
Starting torque: 0.00Hz 180% rated torque
Speed range: 1:1000
Steady speed accuracy: ± 0.02%
◆ Open loop torque control method:
Independent current loop control achieves true torque control, supporting online switching between torque and speed control.
Torque accuracy: ± 5%
Torque response:<20ms
◆ Closed loop torque control method:
Independent current loop control achieves true torque control, supporting online switching between torque and speed control.
Torque accuracy: ± 5%
Torque response:<10ms



V6-H-4T □□□ G three-phase 400V constant torque/heavy load application

Power (KW)

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

75

Suitable motor power (KW)

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

75

output Voltage (V) Three phase 0~rated input voltage
Rated current (A)

2.5

3.8

5.5

9

13

17

24

30

39

45

60

75

91

112

150

Overload capacity 150% 1 minute, 180% 10 seconds, 200% 0.5 seconds, with an interval of 10 minutes (inverse time characteristic)
input Rated voltage/frequency 3-phase 380V~480V; 50/60Hz
Allowable voltage range 323~528; Voltage imbalance: ≤ 3%; Allowable frequency fluctuation: ± 5%
Rated current (A)

3.5

6.2

9.2

14.9

21.5

27.9

39

50.3

60

69.3

86

104

124

150

201

BRAKE UNIT Standard built-in Built in optional
protection grade IP20
Cooling method Self cooling Forced air cooling




Power (KW) 90 110 132 160 200 220 280 315 355 400 .. .. .. .. ..
Suitable motor power (KW) 90 110 132 160 200 220 280 315 355 400
output Voltage (V) Three phase 0~rated input voltage
Rated current (A) 176 210 253 304 377 415 520 585 650 740
Overload capacity 150% 1 minute, 180% 10 seconds, 200% 0.5 seconds, with an interval of 10 minutes (inverse time characteristic)
input Rated voltage/frequency 3-phase 380V~480V; 50/60Hz
Allowable voltage range 323~528; Voltage imbalance: ≤ 3%; Allowable frequency fluctuation: ± 5%
Rated current (A) 160* 196* 232* 282* 352* 385* 491* 552* 624* 704*
BRAKE UNIT External braking unit required
protection grade IP20
Cooling method Forced air cooling

*V6-H-4T90G and above product standard external DC reactor

V6-H-4T □□□ L three-phase 400V variable torque/light load application

Power (KW) 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90
Suitable motor power (KW) 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90
output Voltage (V) Three phase 0~rated input voltage
Rated current (A) 3.3 5 7.5 11 17 22 30 36 45 56 72 91 110 142 176
Overload capacity 115% 1 minute, 160% 0.5 seconds, with an interval of 10 minutes (inverse time characteristic)
input Rated voltage/frequency 3-phase 380V~480V; 50/60Hz
Allowable voltage range 323~528; Voltage imbalance: ≤ 3%; Allowable frequency fluctuation: ± 5%
Rated current (A) 5.6 8.1 13.5 19.5 26 39 50.3 60 69.3 86 104 124 150 190 235
BRAKE UNIT Standard built-in Built in optional
protection grade IP20
Cooling method Self cooling Forced air cooling


Power (KW) 110 132 160 200 220 280 315 355 400 450 .. .. .. .. ..
Suitable motor power (KW) 110 132 160 200 220 280 315 355 400 450
output Voltage (V) Three phase 0~rated input voltage
Rated current (A) 215 253 304 377 415 520 585 650 740 840
Overload capacity 115% 1 minute, 160% 0.5 seconds, with an interval of 10 minutes (inverse time characteristic)
input Rated voltage/frequency 3-phase 380V~480V; 50/60Hz
Allowable voltage range 323~528; Voltage imbalance: ≤ 3%; Allowable frequency fluctuation: ± 5%
Rated current (A) 195* 232* 282* 352* 385* 491* 552* 624* 704* 792*
BRAKE UNIT External braking unit required
protection grade IP20
Cooling method Forced air cooling

*V6-H-4T110L and above product standard external DC reactor




Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!