Technical parameters:
Pressure measurement range: -300 to 300 psi (-2068 to 2068 kPa)
Measurement range: -20 to 300 psi (-138 to 2068 kPa) (-40 to 610 in. Hg)
Resolution (optimal): 0.001 psi (0.01 kPa) (0.01 in. Hg)
Accuracy 1: ± 1% of reading. 072 psi (0.5 kPa) (0.15 in. Hg)
Measurement units: psi, in. H2O, ft H2O, kPa, mm Hg, in. Hg, m H2O, bar
Pressure pipe joint: ¼ "37 • flare fitting, Male
temperature
Operating temperature (electronic) 40 to 113 ° F (5 to 45 ° C)
Storage: -4 to 140 ° F (-20 to 60 ° C)
Liquid medium: 32 to 180 ° F (0 to 82 ° C)
Probe (Immersion) -40 to 250 ° F (-40 to 121 ° C)
Resolution: 0.1 ° F (0.1 ° C)
Accuracy: ± 0.5% of reading+1.2 ° F (0.7 ° C)
Unit: ° F, ° C
Flow range 2: -22712 to 22271 m3/h, -99999 to 99999 USGPM (-6309 to 6309 l/s)
Resolution (optimal): 0.0001 USGPM (0.00001 l/s)
Accuracy: precision per pressure+valve deviation
Units: USGPM, UKGPM, m3/h, l/s, l/m
Measurement cycle: Users can choose (1, 5, 10, 20, and 30 seconds)
Data statistics: minimum, maximum, average, total of 4000 counts
Data storage: 4000 combined reads, 100 test IDs
Record interval: Users can choose (1 to 3600 seconds)
Size: 11.1 in. x 4.7 in. x 3.5 in. (28.2 cm x 11.9 cm x 8.8 cm)
Weight: 2.65 lbs (1.20 kg)
Power adapter: 4 AAs, or AC adapter
Balance valve flow tester
Model: HM685
The HM685 balance valve flow tester is used to balance liquid circulation heating and cooling systems, check pump performance, and set balance valves. It can measure and display pressure difference, high pressure side, and low pressure side pressure simultaneously without changing hose connections or instrument valve settings.
The components include:
·Instrument host
·Hard suitcase
·(2) 6.7 ft x ¼ - in. Hose with shut-off valve (2 m x 6 mm)
·(2) B&G readout probe
·(2) P/T table adapter probe
·Power cord
·Temperature probe
· CompuDat ™ USB download software
·USB data cable
Characteristics and advantages
Support dual temperature probe input
Backlit large screen, able to display clearly even in low light conditions
Powered by four rechargeable alkaline or nickel hydrogen batteries
Reading method H 2 O, ft, H 2 O, psi, in. Hg, mm Hg, m H 2 O, kPa or bar
Pressure difference range ± 300 psi (± 2068 kPa)
Gauge pressure range -20-300 psi (-138-2068 kPa)
Integrate universal traffic and BTU/HR calculation
When setting the Cv (Kv) factor, display the volumetric flow rate
Can input up to 100 Cv (Kv) factors
Calculate braking force, heat flux, Cv (Kv) factor, and pump wheel size
Capable of storing up to 4000 data points for retrieval or downloading via USB port
Durable splash proof instrument box
Weight including battery: 2.65 lbs (1.20 kg)
Note: TSI HM685 from the United StatesBalance valve flow tester, American TSI flow tester, American TSI HM685, TSI HM685, imported balance valve tester, American TSI agent, agent for the full range of American TSI products