BZY-1 tensiometer testing method: Platinum plate method (or platinum ring) * Operation mode: automatic lifting, fully automatic measurement Normally,
Product details
brand CNSHP/Shanghai Equity Price range 10000 to 50000
Origin category domestic application area petroleum

BZY-1 tensiometerTesting method: Platinum plate method (or platinum ring method)

Operation mode: Automatic lifting of sample table, fully automatic measurement



BZY-1 tensiometerTechnical parameters of BZY-2 tension meter:

PRODUCT MODEL

BZY-1

BZY-2

measuring method

Platinum Plate Method (Platinum Ring Method)

Test range mN/m

0-400

0-200

Peeling range mN/m

0-400

0-200

Resolution mN/m

±0.1

±0.01

Standard error mN/m

±0.1

±0.02

repeatability

±0.1

±0.02

data shows

LED display screen

Time

Low concentration samples for 3-5 seconds

Platform lifting

automatic

Platform lifting distance (mm)

60

Signal output interface

RS232C

Real time curve software

standard configuration

supply voltage

AC220V±10%

Dimensions (mm)

400×200×400

Net weight (kg)

15

Ordinary constant temperature pool

High and low temperature constant temperature pool

Temperature display device


BZY-Note: √ Optional; X is not optional

Surface tension meter/contact angle with standard configuration:

1 host 1 alcohol lamp
1 piece of platinum plate 1 pair of tweezers
2 sets of glassware 1 operation manual
1 standard weight 1 set of synchronous real-time curve software

Product Display(Optional accessories and optional devices)

1. Platinum ring
Made of platinum wire with a radius of 0.185mm, with a circumference of 60mm and a ring radius of 9.55mm.
When connecting to a computer during testing, the maximum value can be converted into tension value (unit: mN/m).
Made of platinum wire with a radius of 0.3mm, with a circumference of 60mm and a ring radius of 9.55mm.
When connecting to a computer during testing, the maximum value can be converted into tension value (unit: mN/m).

2. BZY-1/21 ordinary constant temperature pool
By connecting a silicone tube to a constant temperature bath, samples with a temperature range of 0-60 ℃ can be used for measurement. It can also be combined with BZY-1/23 temperature measuring device to display the temperature value of the measured liquid.

BZY-1/22普通恒温池

3. BZY-1/22 high and low temperature constant temperature pool
By connecting a silicone tube to a constant temperature bath, samples with a temperature range of -5~110 ℃ can be used for measurement. And BZY-1/23 temperature measuring device can be optionally used in combination to display temperature values.

BZY-1/22高低温恒温池

4. BZY-1/23 temperature measuring device
The sensor composed of PT100 can be inserted into the sample to detect the temperature of the sample in real time. Display range 0~99 ℃, display accuracy 0.1 ℃.

5. When the surface tension test of the tested liquid needs to be carried out under special temperature conditions (extraordinary temperature) of constant temperature, it can be cyclically matched with our factory's super constant temperature bath or low-temperature constant temperature bath to obtain a high-precision and uniform constant temperature field source.

The following figure shows the combination of a tension meter and a constant temperature bath

Third party calibration certificate for tension tester

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!