1、 Product Introduction:

1. Temperature range: 0 ℃ to 70 ℃

2. Temperature range with illumination: 10 ℃ to 60 ℃

3. Humidity range: 10% relative humidity to 80% relative humidity

4. 3 variable positioning lighting boxes with UV/Vis illumination that meets ICH requirements

5. Independent light dose control of UV-A and visible light using spherical sensors

6 APT.lineTMPreheating chamber technology

7. Using capacitive humidity sensors and steam humidification for humidity regulation

8. The interior is entirely made of stainless steel

9. Intuitive touch screen controller using interval programming and real-time programming

10. Internal data logger and open format measurement values can be read through USB

11. Equipment self-test is used for comprehensive status analysis

12. The sealed inner door is made of safety glass (ESG)

13. Prevent corrosion of glass through a special TIMELESS coating.

14. 3 sockets made of stainless steel

15. Access hole with silicone plug 30mm, left

16. 4 stable casters, 2 with brakes

17. Independently adjustable temperature safety device Class 3.1 (DIN 12880), equipped with optical and acoustic temperature alarms

18. Computer interface: Ethernet

19. Door heating

2、 Technical parameters:

Product model KBFLQC720-230V1 KBFLQC720UL-240V1
Choose a model standard standard
Item code 9020-0334 9020-0335
measure
Internal volume [L] 700 700
Net weight of equipment (unloaded) [kg] 374 374
Maximum total load [kg] 150 150
Maximum load per partition [kg] 45 45
The dimensions of the casing do not include additional components and connectors
Net weight width [mm] 1250 1250
Net weight at height [mm] 1925 1925
Depth net weight [mm] 890 890
Wall distance from rear [mm] 100 100
Wall to side distance [mm] 200 200
Internal dimensions
Width [mm] 973 973
Height [mm] 1250 1250
Depth [mm] 576 576
The number of doors
Inner door 2 2
Outer door 2 2
Data related to the environment
Energy consumption at 40 ℃ and 75% relative humidity [Wh/h] 2350 2350
Sound pressure level [dB (A)] 53 53
firmware
Number of partitions (hours/maximum) 3/12 3/12
Number of Lighting Boxes (Standard/Maximum) 3/3 3/3
Temperature performance data
Temperature range with 100% illumination [℃] 10…60 10…60
Temperature range without lighting box [℃] 0…70 0…70
Maximum thermal compensation at 40 ℃, with illumination [W] 1000 1000
Climate performance data
Temperature range without lighting box [℃] 10…70 10…70
Temperature range with 100% illumination [℃] 20…60 20…60
Temperature deviation with illumination, at 25 ℃ and 60% relative humidity [± K] 1.2 1.2
Temperature deviation with illumination, at 40 ℃ and 75% relative humidity [± K] 1.2 1.2
Temperature fluctuation with illumination, at 40 ℃ and 75% relative humidity [± K] 0.2 0.2
Temperature fluctuation with illumination, at 25 ℃ and 60% relative humidity [± K] 0.2 0.2
Humidity range without lighting box [% relative humidity] 10…80 10…80
Humidity range with lighting box, with lighting [% relative humidity] 10…75 10…75
Humidity fluctuation with illumination, at 40 ℃ and 75% relative humidity [± relative humidity] 2 2
Humidity fluctuation with illumination, at 25 ℃ and 60% relative humidity [± relative humidity] 2 2
The humidity recovery time after opening the door in 30 seconds is at 40 ℃ and 75% relative humidity, with lighting [min] 5 5
The humidity recovery time after opening the door in 30 seconds is at 25 ℃ and 60% relative humidity, with lighting [min] 1 1
Lighting data for each lighting box
ICH compliant lighting (visible light) [lx]* 9000 9000
ICH compliant illumination (UV light) [W/m2]* 1.5 1.5
Electrical data
Rated voltage [V] 200…230 200…240
Power frequency [Hz] 50 50/60
Rated power [kW] 3.5 3.5
Equipment safety device [A] 16 16
Phase (rated voltage) 1~ 1~

1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. The technical data assumes a fan speed of 100%. We reserve the right to make technical changes* The average value measured under the illumination box using a spherical sensor (± 10%) 12 cm at 25 ℃. The measurement unit is W/m2, which involves total radiation.