BF series/forced convection microbial incubator
BF series is suitable for laboratories that require cultivation, the new generation APT.lineTM Technology provides a uniform temperature distribution for the enclosure.
The controller comes with a timing function that allows for easy adjustment of the fan, temperature, and forced convection conditions.
• Performance characteristics and equipment
-Electronic controlled APT.line® Internal preheating technology
-Temperature range: from 7 ° C above ambient temperature to 100 ° C (BF56, BF260);
-Controller with LCD display screen
-Timer function: delayed on, delayed off, and temperature dependent delayed off
-Single slope function
-Fan speed adjustable (0-100%)
-Adjust the ventilation volume through the exhaust pipe with ventilation flaps at the back (diameter 50mm) and the ventilation slide in front
-Interior door made of safety glass (ESG)
-Independent adjustable temperature safety device, Class 3.1 (DIN12880), with visual temperature alarm
-Used for communication software APT.COM® The Data Control SystemRS422 interface, or use RS232/RS422 interface converter to convert to printer output port
-The interval time between printers can be adjusted
-Boxes of 115 liters or less can be stacked
-2 chrome plated shelves
Technical specifications of BF series
BF56 |
BF115 |
BF260 |
BF400 |
BF720 |
|
Dimensions |
|||||
Width (millimeters) |
560 |
710 |
810 |
1235 |
1235 |
Height (including legs and casters) (millimeters) |
625 |
735 |
965 |
1025 |
1530 |
Depth (millimeters) |
565 |
605 |
760 |
765 |
865 |
Add door handle, I-panel, and exhaust pipe (in millimeters) |
90 |
90 |
105 |
90 |
90 |
Distance between side and wall (mm) |
100 |
100 |
100 |
100 |
100 |
Distance between the rear face and the wall (in millimeters) |
160 |
160 |
160 |
160 |
160 |
Exhaust pipe outer diameter (mm) |
52 |
52 |
52 |
52 |
52 |
Steam space volume (liters) |
70 |
142 |
283 |
457 |
808 |
Number of doors |
1 |
1 |
1 |
2 |
2 |
Internal dimensions |
|||||
Width (millimeters) |
400 |
550 |
650 |
1000 |
1000 |
Height (millimeters) |
440 |
550 |
780 |
800 |
1200 |
Depth (millimeters) |
340 |
380 |
510 |
500 |
600 |
Internal volume (liters) |
59 |
114 |
257 |
400 |
720 |
Chrome plated shelves (standard quantity/maximum quantity) |
2/4 |
2/5 |
2/8 |
2/9 |
2/15 |
Load per shelf (kg) |
30 |
30 |
40 |
35 |
45 |
Maximum total load (kg) |
70 |
150 |
270 |
90 |
120 |
Net equipment quantity (kg) |
38 |
54 |
85 |
145 |
180 |
temperature data |
|||||
Temperature range (° C) |
Room temperature+7 to 100 |
Room temperature+8 to 100 |
Room temperature+7 to 100 |
Room temperature+5 to 100 |
Room temperature+7 to 100 |
Temperature deviation: 37 ° C(±°C) |
0.3 |
0.3 |
0.3 |
0.4 |
0.4 |
Temperature fluctuation range: 37 ° C(±k) |
0.1 |
0.1 |
0.1 |
0.1 |
0.1 |
Heating time to 37 ° C (min) |
8 |
8 |
8 |
12 |
17 |
Recovery time after opening the door for 30 seconds: at 37 ° C (minutes) |
3 |
4 |
4 |
5 |
4 |
Electric data |
|||||
Protection level of enclosure in accordance with EN60529 standard |
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |
Nominal voltage(±10%) 50/60 Hz (V) |
230 |
230 |
230 |
230 |
230 |
Nominal power (watts) |
400 |
400 |
900 |
850 |
1250 |
Energy consumption noise level (dB (A)) |
43 |
43 |
43 |
- |
- |
Energy consumption at 37 ° C (watts) |
60 |
60 |
70 |
56 |
80 |
Equipment safety device (A) |
6.3 |
6.3 |
8 |
12.5 |
12.5 |
All technologies are only applicable to22±3 ° C ambient temperature and±Standard specification unloaded equipment under 10% power supply voltage fluctuation. Determine temperature data according to BINDER factory standards and DIN12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. Reserved the right to make technical changes