Shenzhen Kerei Technology Development Co., Ltd
Home>Products>AFS array flux gate sensor detection system
AFS array flux gate sensor detection system
Description: The system can connect up to 128 3D flux gate sensors The range of the 3D flux gate sensor is optional, with a measurement resolution of
Product details

Tags: 3D Flux Gate Sensor Flux Gate Array Flux Gate Multi point Measurement GFP803 Data Processing Unit Weak Magnetic Measurement Geomagnetic Measurement

Provide professional magnetic field measurement solutions

Strong magnetic field measuring instrument(0 - 20T)

model

principle

type

number of axles

DCaccuracy

maximum range

Highest resolution

X113

hall

hall sensor

1

<>

15T

TC: 30ppm/K

G80

hall

handheld

1

2%

2T

10μT

G81

hall

handheld

1

0.8%

10T

1μT

G82

hall

handheld-high frequency

1

0.8%

10T

1μT

G83

hall

handheld

3

0.8%

10T

1μT

G92

hall

handheld

1

1%

10T

10μT

G93

hall

handheld

3

1%, 0.5%

20T

1μT

G201

hall

Desktop computer

1

0.2%

10T

1μT

G203

hall/reluctance

Desktop computer

3

0.2%

10T

10nT

G401

hall

Desktop computer

1

0.04%

10T

1μT

G403

hall

Desktop computer

3

0.04%

10T

1μT

GSP301A

hall

Analog transmitter

1

1%, 0.2%

10T

Output: ±3V

GSP301D

hall

Digital transmitter

1

1%, 0.2%

10T

1μT

GSP303D

hall

Digital transmitter

3

1%, 0.2%

20T

1μT

GSP303D-S

hall

Digital transmitter

3

0.5%, 0.1%

3T

1μT

Magnetic field testing system

GAS3000

Array magnetic field detection system, synchronous detection up to128The magnetic field at a certain location

GMS980

High precision Gaussian meter calibration system (High precision Tesla meter calibration device)

Weak magnetic field measuring instrument(0- 2mT)

Weak magnetic field Gaussian meter

model

principle

type

number of axles

DCaccuracy

maximum range

Highest resolution

GMR61

reluctance

handheld

1

0.8%

600μT

10nT

GMR63

reluctance

handheld

3

0.8%

600μT

10nT

GF601

fluxgate

handheld

1

0.5%

1mT

0.1nT

GF603

fluxgate

handheld

3

0.25%

1mT

0.1nT

GF633

fluxgate

Desktop computer

3

0.1%

100μT

0.01nT

GFP703

fluxgate

Smart Transmitters

3

0.5%

1mT

0.1nT

GFP703S

fluxgate

Spectrum analyzer

3

0.5%

1mT

0.01nT

GFP803

fluxgate

Smart Transmitters

3

0.2%

1mT

0.1nT

Communication magnetic field measurement(DC- 1MHz)

model

principle

type

number of axles

ACaccuracy

maximum range

frequency response

AMS-2K

alternating current coil

Analog sensor

1

1%

3mT

30Hz- 2kHz

AMS-1M

alternating current coil

Analog sensor

1

1%

3mT

2kHz- 1MHz

G1000

reluctance

Smart Transmitters

3

DC- 1% AC- 2%

400μT/ Axis

DC- 1MHz

GA1000

reluctance

handheld

3

2%

400μT/ Axis

30Hz- 1MHz

GSP301HFA

reluctance

Analog transmitter

1

1%

150μT

20Hz-1.2MHz

GSP303HFA

reluctance

Analog transmitter

1

1%

150μT

20Hz-1.2MHz

fluxgate sensor

model

principle

type

number of axles

noise level

maximum range

output

F901

fluxgate

Economic type

3

10 to 20pT

1000μT

±10V,single-ended

F902

fluxgate

low noise

3

<>

100μT

±10V,single-ended

F903

fluxgate

low-power consumption

3

10 to 20pT

200μT

±3V,finite difference

F904

fluxgate

low-power consumption|low noise

3

<>

100μT

±3V,finite difference

F905

fluxgate

high-performance|low noise

3

<>

100μT

±10V,single-ended

F906

fluxgate

low-power consumption

3

10 to 20pT

100μT

±3V,finite difference

F23

fluxgate

split type|large range

3

<>

1500μT

±10V,single-ended

F53

fluxgate

High temperature type

3

≤ 300pT@175

100μT

±5V,finite difference

Magnetic flux gate sensor data acquisition unit

FDU301

Connectable1A three-axis flux gate sensor

ASA1000

Connectable2-126A single axis flux gate sensor or2-42A three-axis flux gate sensor

AFS

Array flux gate sensor detection system, capable of connecting multiple flux gate magnetic field transmitters

GMR-16

Micro weak magnetic field sensor array, capable of synchronous acquisition2-16Data from a miniature weak magnetic field sensor

GR100

Digital three-axis flux gate gradiometer

remarks:

1Magnetic field unit conversion:1T= 10kG; 1mT= 10G; 1μT= 10mG; 1nT= 10μG

2Click on the left side of the table abovemodelYou can refer to the product information of the corresponding model



AFS array flux gate sensor detection system


sketch:

The array flux gate sensor detection system AFS consists of multiple three-dimensional flux gate sensors (up to 128), high-speed RS485 communicator, USB converter, upper computer software, and computer. The array flux gate sensor detection system AFS can meet the needs of weak magnetic field multi-point testing in scientific research units. It has the advantages of fully automatic bus based digital signal transmission, computer-controlled acquisition speed, data storage and processing, drawing various curve charts, spectrum and RMS analysis (options).

The array flux gate sensor detection system AFS can simultaneously connect 1-128 three-dimensional flux gate sensors, with each sensor having an accuracy of<><>

Option: Each flux gate sensor can not only output three-dimensional magnetic field data at high speed, but also perform frequency spectrum analysis of AC magnetic fields and calculate the total RMS data. Spectrum analysis range 2Hz-500Hz, frequency accuracy 1Hz, RMS magnetic field accuracy<>

The array flux gate sensor detection system AFS is suitable for multi-point testing of various weak magnetic fields in space, multi-point online monitoring of environmental magnetic fields, magnetic ship model magnetic field measurement experiments, on-site testing of electron microscopy and magnetic resonance equipment pre installation, and judgment of magnetic shielding effect. The array flux gate sensor detection system AFS can be customized according to user needs to meet their special requirements.



Performance advantages:

The system can connect up to 128 3D flux gate sensors;
The range of the 3D flux gate sensor is optional, with a measurement resolution of up to 0.1nT;
Simultaneous acquisition by multiple probes and synchronous display by computer software;
Adopting industrial grade RS485 high-speed communicator, fast speed and high stability;
Computer controlled acquisition speed and data processing, fully automated bus based digital signal transmission;
The communication cable can reach a maximum length of 500 meters.


Upper computer software






AFS array flux gate sensor detection system

Array Flux Gate Sensor Detection System

describe

computer

operating system

Win8, Win10

Configuration Requirements

Conventional mainstream configuration

systems software

function

1Real time display of magnetic field strengthXYZComponent value and vector value

2Real time saving of magnetic field strength data to computer

3Spectrum andRMSMeasurement mode (option)

4Multi probe connection and display mode(128Within one probe

MSCSynchronous collector

Number of channels

8, 16, 32, 64, one hundred and twenty-eightoptional

Working power supply

DC 9-40V 500mA

Communication Distance

500rice

Transmission medium

Twisted pair or shielded wire

Usage environment

-20~ +85Relative humidity>95%RH

Three dimensional flux gate sensor

power supply

±15V DC

range

±100μTor±1000μT[optional]

typicalDCaccuracy

±0.2% Reading ± 0.1% FS

Highest measurement resolution

full scale0.1nT(Sensor range)100uTData output rate<>

full scale0.1nT (Sensor range1000uTData output rate<>

frequency response(-3dB)

DC- 1.5kHz

Typical temperature coefficient

±200ppm/[Without temperature compensation]

±30ppm/[After temperature compensation]

Spectrum analysis andRMSMeasurement function

2Hz-500HzFrequency accuracy1HzRMSaccuracy<1% >1% >[optional]

Sensor orthogonality error

<1°>1°>or<>[optional]

Data output interface

RS485

3Output rate of magnetic field data

1, 5, 10, 50, 100, 500, 1000spsoptional

operation temperature

-30~ +60

size(L x W x H)

151 x 32 x 32mm

protection grade

IP68




Product Selection

1. Selection of RS485 high-speed communicator

MSC

-8

MSCSynchronous collector

Number of connection channels (Number of 3D flux gate sensors that can be connected)

-88individual

-1616individual

-3232individual

-6464individual

-128128individual



2. Selection of Three Dimensional Flux Gate Sensors

GFP803

-01

-2m

-E

-T

-DS

Three dimensional flux gate sensor

range

-01100μT

-101000μT

Cable Length

-2m2m

-5m5m

-10m10m

-20m20m

……

Orthogonality error

Default:<>

-E<>

temperature compensation

Default: None

-Thave

Package Specifications

Default: Normal encapsulation

-DS: Deep diving(underwater50rice)


Click to view other magnetic measurement devices



Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!