Zhejiang Heneng Environmental Technology Co., Ltd
Home>Products>5800-GO portable VOCs online analyzer
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13588469093
  • Address
    903, Building 2, China Communications Fortune Building, No. 913 Moganshan Road, Hangzhou City, Zhejiang Province
Contact Now
5800-GO portable VOCs online analyzer
5800-GO portable VOCs online analyzer
Product details

5800-GO portable VOCs online analyzer


The Thermo Scientific 5800-GO portable VOCs online analyzer uses the mature and stable GC-FID technology to perform on-site qualitative and quantitative analysis of methane/non methane hydrocarbons, benzene derivatives, and other components in the sample, with a detection limit of up to ppb level. This instrument fully complies with national standards and methods for VOC analysis (such as HJ/T38, HJ732, HJ734, etc.), allowing customers to inspect, verify, and calibrate existing detection systems in various occasions. This system is suitable for on-site detection of ambient air and emissions from pollution sources.


For VOCs sample analysis in ambient air (normal pressure) or negative pressure environment, the sample gas enters the analyzer after passing through the built-in filter, and the analyzer's built-in sampling pump guides the sample into the quantitative loop for accurate quantification. Then, the preset program controls the switching of the injection valve, and the sample gas is carried into the dedicated chromatographic column by the carrier gas for separation. The separated components are sequentially detected by the detector. The built-in work software automatically completes data collection, analysis, processing, storage, and transmission.


The analysis system for gas emissions from pollution sources allows real-time analysis of gas inside pipelines without making any changes to the original system. The sample transfer heating and insulation tube selected by the system ensures that the sample will not condense during the sampling stage, while the portable gas cylinder companion provided by the instrument not only provides the necessary carrier gas (nitrogen), hydrogen, and zero air for the instrument, but also has a built-in standard gas for on-site calibration or inspection of the instrument.


Product features:


High quality portable steel cylinder gas


Compared to traditional fixed VOCs analyzers, the 5800-GO is more portable and flexible, and can be carried handheld to the testing site. In conjunction with the 5800-GO portable gas cylinder companion, all gases required for instrument operation can be provided: hydrogen, zero air, and nitrogen. The hardware such as high-pressure steel cylinders, high-performance stainless steel pressure reducing valves, and safety valves built into the system can provide safe and reliable external gas for the instrument, ensuring that the analysis results are completely consistent with the laboratory analysis results. When the gas cylinder is fully filled, H2 and N2 can support continuous operation of the instrument for more than 30 hours, while air can support up to 8 hours.


The above portable steel cylinder gas solution can effectively eliminate accuracy issues caused by impurities and fluctuations in homemade zero air and hydrogen gas on site. And users can focus on sample analysis without worrying about ineffective work caused by external gas source quality issues.


Rich configuration


The 5800-GO has 4 major series to meet the needs of customers in different application scenarios. The following are model specifications.

option

describe

Basic Edition

Standard Edition

professional edition

Deluxe Edition

1

Analyzer (includingPC)

2

External4L nitrogen, hydrogen, and air cylinders




3

Portable gas cylinder companion

(including nitrogen, hydrogen, air, and standard gas)


4

Sampling pipeline (insulation), filter and joint,3m



5

Sampling pipeline (heating), filter, and connector,3m



6

Sampling probe component

(including probe, handle, and options)5)



7

Enhance sampling probe components

(including probe with shortcut keys and display screen, handle, and options)5)



8

Battery Companion




9

Sampling pump, no residual sampling airbag(10) and connection adapters



10

Sampling pump, residue free airbag, connection adapter, and Suma tank connection adapter




Detachable design, remote control instrument


The 5800-GO supports industrial WiFi, which enables remote connection between the analyzer and the controller. The control computer inside the device can be separated from the host, and users can place the instrument on site. The instrument can be controlled through WiFi for sampling, data storage, and analysis. After the analysis is completed, users can perform post-processing on the data through the computer.


Laboratory level precision and flexibility


The 5800-GO standard configuration is a gas chromatography combined with a hydrogen flame ionization detector (GC-FID), which has high detection accuracy and a wide linear detection range; The system design ensures the insulation of the entire sample path, avoiding the residue of high boiling point substances; The whole EPC system improves the accuracy of gas flow control, ensuring the repeatability and accuracy of data, and also ensuring the long-term stability of instrument operation. At the same time, the system is equipped with Thermo Fisher's Uniheat technology, which can make the instrument ready within 10 minutes and then directly analyze the sample, thereby improving the analysis efficiency of the entire system. The 5800-GO also features custom shortcut keys for quick sample analysis with just one click, further enhancing users' work efficiency at the testing site.


On the basis of standard non methane total hydrocarbon analysis, the instrument supports the analysis of various benzene based compounds, including benzene, toluene, ethylbenzene, xylene, etc. All analyses are based on national standard methods, and the results can be directly compared in parallel with laboratory analysis results.


Expandable sampling probe, supporting direct sampling at the outlet


The sampling probe of 5800-GO supports multiple configurations, and the probe is equipped with a quick press and instrument information display screen. The sampling pipeline is heated throughout the entire process to ensure that there is no condensation of the sample. The sampling tube adopts an inert pipeline inside, effectively preventing the adsorption and loss of samples on the pipeline.


Other characteristics


The analysis covers a wide range of components, including methane, non methane hydrocarbons, benzene derivatives, etc


Built in sample filter for quick replacement


Support analysis of positive pressure, normal pressure, and negative pressure samples


Expand the automatic sequential sampling analysis of sampling bags or Suma cans


Support full process pressure monitoring and recording of sampling bags and Suma tanks


Support programmable (0-10L) sampling volume and recording for sampling bags and Suma cans


Technical parameters:

General parameters


Analysis method

Gas chromatography combined with hydrogen flame ionization detector(GC-FID)

Analyze the components

TVOC、 Methane, non methane hydrocarbons, benzene derivatives (optional)

measuring range

0-50,500,5000,50000ppm

LoD

(Calculated as propane): 30ppb

zero drift

0.1% or 60ppb/24 hours

Span drift

0.5% full scale/24 hours

repeatability

1.5% (1ppm methane)

Measurement period

2min (methane/non methane total hydrocarbons); ≤ 10 minutes (benzene derivatives)

sample flow

make an appointment100ml/min

Column temperature

ambient temperature+15 ℃ -220 ℃, control accuracy of 0.1 ℃

VALVE

Membrane valve, operating temperature range30-180 ℃ (controllable temperature)

Valve switching mode

aerodynamic

Pneumatic control

High precision full flow pathEPC control, accuracy 0.01Psi

detector

Hydrogen flame ionization detector(FID)

Linear range of detection signal

107(+/-10%)

detector guard

Automatic ignition, fire extinguishing, automatic gas cut-off, and alarm function

gas

H2, 99.999%,30-50ml/min

oxidant gas

Clean air,300-500ml/min

carrier gas

Nitrogen (standard) or hydrocarbon free clean air,30-50ml/min

Software and Control


Built in industrial computer

Intel host, 4G memory, high-speed solid-state drive (capable of storing data for continuous operation for 2 years)

Main control computer

Detachable with safety lock

Instrument anti control software

Built in system control software, automatically completes sampling, analysis, and periodic calibration/System response measurement can achieve 7x24 automatic unmanned operation and automatic calibration, aging and other functions of the system

Remote control

Support, capable of parameter setting, editing, and result processing operations.

Shortcut keys

Support (customizable)

data export

supportMS EXCEL, CSV, TXT

status indicator

Dynamically display ready, sampling, error and other information

Alarm Message

Self diagnostic alarm

Basic information


size/Weight

400mm(L)×500mm(W)x 230mm(H),~13kg

Power requirements

24VDC±10%,8A

operate temperature

0 ℃ -40 ℃, 5-85% non condensing

storage temperature

-20 ℃ to 50 ℃

Joint size and type

1/8 inch Swagelok stainless steel sleeve thread (optional 1/4 inch)

instrument interface

Heating tube interfaceX1, USBx1, 3G/4G network remote diagnosis (optional)

Touch Screen

12 "(standard)

Communication method

Modbus TCP/IP (standard)

5800 GO Portable Gas Cylinder Companion


size/Weight

430mm(L)×530mm(W)x 300mm(H),~15kg

With pull rod and roller

operate temperature

0 ℃ -40 ℃, 5-85% non condensing

storage temperature

-20 ℃ to 50 ℃

Number of gas cylinders

4 (withstand pressure>2000psi)

pressure reducing valve

Built in stainless steel

safety valve

Built in stainless steel

Joint size and type

1/8 inch Swagelok stainless steel sleeve thread

Inflator device

standard configuration2 sets (including standard interface and hydrogen dedicated interface)


The information about the 5800-GO portable VOCs online analyzer is provided by Thermo Fisher Environment and Process. If you would like to learn more about the quotation, model, parameters, and other information of the 5800-GO portable VOCs online analyzer, please feel free to call or leave a message for consultation.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!