main features
Simultaneously measuring conductivity PH、 Five parameters: temperature, residual chlorine, and turbidity. Five parameters are displayed on the same screen, also known as a conventional five constant water quality analyzer. The turbidity sensor is equipped with a scraper cleaner, which reduces maintenance workload and improves work reliability. Each channel is independent of each other and does not interfere with each other. Electromagnetic compatibility (EMC/RFI) design: Designed and manufactured according to European standard EN50081/50082. Waterproof and dustproof design: protection level IP65, suitable for outdoor use. Chinese LCD display, Chinese menu style, Chinese note taking. Industrial control watchdog: ensures that the instrument does not crash.
TECHNICAL INDEX
1、 Conductivity:
1) Measurement range: electrode constant × (1-3000) μ S/cm, 0-99.9 ℃. 0.01 - 30μS/cm; (0.01 electrode); 0.1 - 300μS/cm; (0.1 electrode). 1.0 - 3000μS/cm; (1.0 electrode); 10 - 30000μS/cm; (10.0 electrode).
2) Accuracy:+ 0.5%FS,+ 0.5 ℃.
IIpH:
1) Measurement range: (0.00 - 14.00)pH。
2) Basic error of electronic unit: ± 0.02pH.
3) Basic error of the instrument:+ 0.05pH,+ 0.5 ℃.
3、 Temperature:
1) Measurement range: (0.0-100.0) ℃.
2) Basic instrument error:+ 0.5 ℃ (0.0. C ≤ T ≤ 60.0 ℃): Other ranges: ± 1.0 ℃.
4、 Residual chlorine:
1) Measurement range: 0-20.00mg/L; Resolution O Olmg/L;
2) Accuracy: residual chlorine,+2% or ± 0.035mg/L, whichever is greater+ 0.5 ℃.
5、 Turbidity:
1) Range: 0-100NTU, 0-500NTU, 0-1000NTU, 0-3000NTU: Different sensors are equipped for different ranges. Please indicate the measurement range when placing an order; If it is greater than 3000NTU, please choose 5901-jk-50000 suspended solids (sludge) concentration meter electrode.
2) Accuracy: ± 2%.
3) The sensor is equipped with an automatic cleaning function, and the cleaning blade is integrated with the sensor without the need for peripheral components.
6、 Each channel is independent of each other, and the data of each channel is measured simultaneously.
7、 Conductivity pH、 Temperature, residual chlorine, and turbidity are displayed on the same screen.
8、 Current isolation output: Each parameter is independent 4-20 mA (load<750 Q).
9、 Power supply: AC220V+22V、50Hz+1Hz, Optional DC24V+2.4V.
10、 RS485 communication interface (optional).
11、 Protection level: IP65。
12、 Working conditions: ambient temperature from 0 to 60 degrees Celsius. C, Relative humidity ≤ 90%.
13、 Secondary instrument weight and size: l.0kg、146x146x108 mm。
14、 Hole size: 138x138mm.
15、 Installation methods for secondary meters: perforated, wall mounted, rack mounted, and pipe mounted.
16、 Electrode installation methods: flow type, submerged type, flange type, pipeline type.
Ordering Guide
1. Please inform us of the required parameters for instrument configuration and electrode selection. For example: PH、 Temperature, residual chlorine, turbidity, or a combination of residual chlorine, temperature, and turbidity.
2. The installation method of the sensor is not specified and should be configured in a flow-through manner.
3. The installation method of the secondary instrument is not specified and is configured in an open hole manner.
4. Optional stainless steel installation box for outdoor installation.
5. Turbidity measurement range, not specified, configured as 0-100 NTU.
6. The measurement range of conductivity is between 0-2000 μ S/cm without explanation.
Turbidity meter electrode
Conductive electrode PH electrode Residual chlorine electrode