20Air-cooled chillerThe parameters are as follows:

1、 Chiller parameter table:

AC-20AD air-cooled chiller specifications and technical parameters table

Serial Number name Specification type performance parameter

1 model AC-20AD

2 Refrigeration capacity kW 59.08 (outlet temperature 10 ℃, condensing temperature 50 ℃)

kcal/h 50808.8 (outlet temperature 10 ℃, condensing temperature 50 ℃)

3 power supply V 3PH-380V-50HZ

4 Whole machine power kW 22.8

5 Whole machine current A 55.4

6

compressor type Fully enclosed vortex type

Cooling input power(kW) 7.5*2

Cooling operation current(A) 18*2

7 fan type YWF

Air volume(m3/h) 20000

8 water pump type Centrifugal pipeline pump

Head lift(mH2O) 20

internet traffic(m3/h) 21

9 condenser type Aluminum finned copper tube type

heat exchange(kW) 75.0

10 evaporator type Shell and tube type

heat exchange(kW) 60.0

internet traffic(m3/h) 12.34

11 water tank material SUS304

volume(L) 285

12 Piping Frozen water media outlet DN50 (according to customer requirements)

Frozen water media inlet DN50 (according to customer requirements)

13 Temperature digital microcomputer controller Display status Touch sensitive digital tube display

output Gw532A

Generator selection Relay

Temperature range(℃) +5~+35

Temp Accuracy(℃) ±1.0

14

alarm device Abnormal temperature Alarm for low circulating water temperature and cut-off of compressor

Reverse phase of power supply Power phase detection to prevent pump and compressor reversal

High and low voltage faults Pressure switch detects the pressure status of the refrigerant system

Compressor overload Thermal relay protects compressor

Compressor overheating Internal protector protects the compressor

Pump overload Thermal relay protection pump

Low water level alarm The water level switch

short circuit Air Switch

15 External dimensions long*Width * Height (mm) 1955*940*1960

16 Whole machine weight kg 590